The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Diagnosis of Periprosthetic Joint Infection: The Utility of a Simple Yet Unappreciated Enzyme
Abstract
BACKGROUND: The white blood-cell count and neutrophil differential of the synovial fluid have been reported to have high sensitivity and specificity in the diagnosis of periprosthetic infection following total knee arthroplasty. We hypothesized that neutrophils recruited into an infected joint secrete enzymes that may be used as markers for infection. In this prospective study, we determined the sensitivity and specificity of one of these enzymes, leukocyte esterase, in diagnosing periprosthetic joint infection. METHODS: Between May 2007 and April 2010, synovial fluid was obtained preoperatively from the knees of patients with a possible joint infection and intraoperatively from the knees of patients undergoing revision knee arthroplasty. The aspirate was tested for the presence of leukocyte esterase with use of a simple colorimetric strip test. The color change (graded as negative, trace, +, or ++), which corresponded to the level of the enzyme, was noted after one or two minutes. RESULTS: On the basis of clinical, serological, and operative criteria, thirty of the 108 knees undergoing revision arthroplasty were infected and seventy-eight were uninfected. When only a ++ reading was considered positive, the leukocyte esterase test was 80.6% sensitive (95% confidence interval [CI], 61.9% to 91.9%) and 100% specific (95% CI, 94.5% to 100.0%), with a positive predictive value of 100% (95% CI, 83.4% to 100.0%) and a negative predictive value of 93.3% (95% CI, 85.4% to 97.2%). The leukocyte esterase level correlated strongly with the percentage of polymorphonuclear leukocytes (r = 0.7769) and total white blood-cell count (r = 0.5024) in the aspirate as well as with the erythrocyte sedimentation rate (r = 0.6188) and C-reactive protein level (r = 0.4719) in the serum. CONCLUSIONS: The simple colorimetric strip test that detects the presence of leukocyte esterase in synovial fluid appears to be an extremely valuable addition to the physician's armamentarium for the diagnosis of periprosthetic joint infection. The leukocyte esterase reagent strip has the advantages of providing real-time results, being simple and inexpensive, and having the ability to both rule out and confirm periprosthetic joint infection. However, additional multicenter studies are required to substantiate the results of our preliminary investigation before the reagent strip can be used confidently in the clinic or intraoperative setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-sided confidence intervals for the single proportion: comparison of seven methods
Newcombe, R. G. (1998) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19980430)17:8<857::aid-sim777>3.0.co;2-e · Cited by 5,107
Zimmerli, W., Trampuz, A., & Ochsner, P. E. (2004) · New England Journal of Medicine · doi:10.1056/nejmra040181 · Cited by 3,116
Sonication of Removed Hip and Knee Prostheses for Diagnosis of Infection
Trampuz, A., Piper, K. E., Jacobson, M. J., Hanssen, A. D., Unni, K. K., Osmon, D. R., Mandrekar, J. N., Cockerill, F. R., Steckelberg, J. M., Greenleaf, J. F., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa061588 · Cited by 1,443
Infection after Total Hip Arthroplasty. A Study of the Treatment of One Hundred and Six Infections*
TSUKAYAMA, D. T., ESTRADA, R., & GUSTILO, R. B. (1996) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199604000-00005 · Cited by 957
Risk Factors for Prosthetic Joint Infection: Case‐Control Study
Berbari, E. F., Hanssen, A. D., Duffy, M. C., Steckelberg, J. M., Ilstrup, D. M., Harmsen, W. S., & Osmon, D. R. (1998) · Clinical Infectious Diseases · doi:10.1086/514991 · Cited by 840
Spangehl, M. J., Masri, B. A., OʼConnell, J. X., & Duncan, C. P. (1999) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199905000-00008 · Cited by 761
Atkins, B. L., Athanasou, N., Deeks, J. J., Crook, D. W. M., Simpson, H., Peto, T. E. A., McLardy-Smith, P., Berendt, A. R., & Group, T. O. C. S. (1998) · Journal of Clinical Microbiology · doi:10.1128/jcm.36.10.2932-2939.1998 · Cited by 725
Synovial fluid leukocyte count and differential for the diagnosis of prosthetic knee infection
Trampuz, A., Hanssen, A. D., Osmon, D. R., Mandrekar, J., Steckelberg, J. M., & Patel, R. (2004) · The American Journal of Medicine · doi:10.1016/j.amjmed.2004.06.022 · Cited by 555
The urine dipstick test useful to rule out infections. A meta-analysis of the accuracy
Devillé, W. L., Yzermans, J. C., van Duijn, N. P., Bezemer, P. D., van der Windt, D. A., & Bouter, L. M. (2004) · BMC Urology · doi:10.1186/1471-2490-4-4 · Cited by 519
SEGAWA, H., TSUKAYAMA, D. T., KYLE, R. F., BECKER, D. A., & GUSTILO, R. B. (1999) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199910000-00008 · Cited by 446
Management of Infection Associated with Prosthetic Joints
Zimmerli, W., & Ochsner, P. E. (2003) · Infection · doi:10.1007/s15010-002-3079-9 · Cited by 372
The role of intraoperative frozen sections in revision total joint arthroplasty.
Feldman, D. S., Lonner, J. H., Desai, P., & Zuckerman, J. D. (1995) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199512000-00003 · Cited by 296
DI CESARE, P. E., CHANG, E., PRESTON, C. F., & LIU, C.-J. (2005) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200509000-00003 · Cited by 255
Comparison of test characteristics of urine dipstick and urinalysis at various test cutoff points
Lammers, R. L., Gibson, S., Kovacs, D., Sears, W., & Strachan, G. (2001) · Annals of Emergency Medicine · doi:10.1067/mem.2001.119427 · Cited by 145
McNair, R. D., MacDonald, S. R., Dooley, S. L., & Peterson, L. R. (2000) · American Journal of Obstetrics and Gynecology · doi:10.1067/mob.2000.105440 · Cited by 104
Evaluation of leukocyte esterase activity as a rapid screening technique for bacteriuria
Perry, J. L., Matthews, J. S., & Weesner, D. E. (1982) · Journal of Clinical Microbiology · doi:10.1128/jcm.15.5.852-854.1982 · Cited by 55
Measurement of urinary leukocyte esterase activity: A screening test for urinary tract infections
Chernow, B., Zaloga, G. P., Soldano, S., et al. (1984) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(84)80603-4 · Cited by 47
Use of leukocyte esterase-nitrate activity as predictive assays of significant bacteriuria
Smalley, D. L., & Dittmann, A. N. (1983) · Journal of Clinical Microbiology · doi:10.1128/jcm.18.5.1256-1257.1983 · Cited by 47
Disappointing dipstick screening for urinary tract infection in hospital inpatients.
Zaman, Z., Borremans, A., Verhaegen, J., Verbist, L., & Blanckaert, N. (1998) · Journal of Clinical Pathology · doi:10.1136/jcp.51.6.471 · Cited by 44
Cited by
Parvizi, J., Tan, T. L., Goswami, K., Higuera, C., Della Valle, C., Chen, A. F., & Shohat, N. (2018) · The Journal of Arthroplasty · doi:10.1016/j.arth.2018.02.078 · Cited by 2,159
Self-citationTande, A. J., & Patel, R. (2014) · Clinical Microbiology Reviews · doi:10.1128/cmr.00111-13 · Cited by 1,885
Metadata
- Authors
- Parvizi, J., Jacovides, C., Antoci, V., & Ghanem, E.
- Venue
- The Journal of Bone and Joint Surgery-American Volume
- Published
- 2011-12
- Volume
- 93
- Issue
- 24
- Pages
- 2242-2248
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2074839975
- Cited by
- 281
- References
- 19
- FWCI
- 19.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.