The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Large Femoral Heads Decrease the Incidence of Dislocation After Total Hip Arthroplasty: A Randomized Controlled Trial
Abstract
BACKGROUND: The use of larger femoral heads has been proposed to reduce the risk of dislocation after total hip arthroplasty, but there is a lack of evidence to support this proposal. The aim of this multicenter randomized controlled trial was to determine whether the incidence of dislocation one year after total hip arthroplasty is significantly lower in association with the use of a 36-mm femoral head articulation as compared with a 28-mm articulation. METHODS: Six hundred and forty-four middle-aged and elderly patients undergoing primary or revision arthroplasty were randomized intraoperatively to receive either a 36 or 28-mm metal femoral head on highly cross-linked polyethylene. Patients who were at high risk of dislocation (including those with dementia and neuromuscular disease) and those undergoing revision for the treatment of recurrent hip dislocation or infection were excluded. Patients were stratified according to other potential risk factors for dislocation, including diagnosis and age. Diagnosis of hip dislocation required confirmation by a physician and radiographic evidence of a dislocation. RESULTS: Overall, at one year of follow-up, hips with a 36-mm femoral head articulation had a significantly lower incidence of dislocation than did those with a 28-mm articulation (1.3% [four of 299] compared with 5.4% [seventeen of 316]; difference, 4.1% [95% confidence interval, 1.2% to 7.2%]) when controlling for the type of procedure (primary or revision) (p = 0.012). The incidence of dislocation following primary arthroplasty was also significantly lower for hips with a 36-mm femoral head articulation than for those with a 28-mm articulation (0.8% [two of 258] compared with 4.4% [twelve of 275]; difference, 3.6% [95% confidence interval, 0.9% to 6.8%]) (p = 0.024). The incidence of dislocation following revision arthroplasty was 4.9% (two of forty-one) for hips with a 36-mm articulation and 12.2% (five of forty-one) for hips with a 28-mm articulation; this difference was not significant with the relatively small sample size of the revision group (difference, 7.3% [95% confidence interval, -5.9% to 21.1%]) (p = 0.273). CONCLUSIONS: Compared with a 28-mm femoral head articulation, a larger 36-mm articulation resulted in a significantly decreased incidence of dislocation in the first year following primary total hip arthroplasty. However, before a 36-mm metal-on-highly cross-linked polyethylene articulation is widely recommended, the incidence of late dislocation, wear, periprosthetic osteolysis, and liner fracture should be established.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moher, D., Hopewell, S., Schulz, K. F., Montori, V., Gotzsche, P. C., Devereaux, P. J., Elbourne, D., Egger, M., & Altman, D. G. (2010) · BMJ · doi:10.1136/bmj.c869 · Cited by 8,883
The Australian Orthopaedic Association National Joint Replacement Registry
Graves, S. E., Davidson, D., Ingerson, L., Ryan, P., Griffith, E. C., McDermott, B. F. J., McElroy, H. J., & Pratt, N. L. (2004) · Medical Journal of Australia · doi:10.5694/j.1326-5377.2004.tb05911.x · Cited by 1,101
BERRY, D. J., VON KNOCH, M., SCHLECK, C. D., & HARMSEN, W. S. (2005) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200511000-00012 · Cited by 516
McKELLOP, H., SHEN, F.-W., LU, B., CAMPBELL, P., & SALOVEY, R. (2000) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200012000-00004 · Cited by 264
Byström, S., Espehaug, B., Furnes, O., & Havelin, L. (2003) · Acta Orthopaedica Scandinavica · doi:10.1080/00016470310017893 · Cited by 174
Risk Factors for Revision for Early Dislocation in Total Hip Arthroplasty
Conroy, J. L., Whitehouse, S. L., Graves, S. E., Pratt, N. L., Ryan, P., & Crawford, R. (2008) · The Journal of Arthroplasty · doi:10.1016/j.arth.2007.07.009 · Cited by 150
Enhancement of Fracture Healing by Mechanical and Surgical Intervention
Chao, E. Y. S., Inoue, N., Elias, J. J., & Aro, H. T. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810001-00018 · Cited by 110
DʼLima, D. D., Hermida, J. C., Chen, P., & Colwell, C. W. (2003) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(02)00240-1 · Cited by 62
Cited by
Risk Factors for Total Hip Arthroplasty Aseptic Revision
Khatod, M., Cafri, G., Namba, R. S., Inacio, M. C. S., & Paxton, E. W. (2014) · The Journal of Arthroplasty · doi:10.1016/j.arth.2014.01.023 · Cited by 61
Metadata
- Authors
- Howie, D. W., Holubowycz, O. T., Middleton, R., & the Large Articulation Study Group
- Venue
- Journal of Bone and Joint Surgery
- Published
- 2012-06-20
- Volume
- 94
- Issue
- 12
- Pages
- 1095-1102
- ISSN
- 0021-9355 (ISSN-L)
- 1535-1386
- OpenAlex
- W2203539912
- Cited by
- 281
- References
- 8
- FWCI
- 17.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.