Optimization of Nonequilibrium Liquid-Phase Microextraction for the Determination of Nitrobenzenes in Aqueous Samples by Gas Chromatography-Electron Capture Detection
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In the present work, a novel method for the determination of nitrobenzenes in water has been described. It is based on nonequilibrium liquid-phase microextraction and gas chromatography-electron capture detection (GC-ECD). Extraction conditions such as solvent selection, organic solvent dropsize, stirring rate, content of NaCl and extraction time were found to have significant influence on extraction efficiency. The optimized conditions were 1.5 μl toluene and 20 min extraction time at 400 rpm stirring rate without NaCl addition. The linear range was 0.1 - 50 μg l^-1 for most nitrobenzenes. The limits of detection (LODs) ranged from 0.02 μg l^-1 (for 2.6-DNT) to 0.4 μg l^-1 (for NB); and relative standard deviations (RSD) for most of the nitrobenzenes at the 10 μg l^-1 level, except for 2,6-DNT in 3 μg l^-1, were below 10%. Natural samples collected from Miyun Reservoir and tap water samples from a laboratory were successfully analyzed using the proposed method, but none of the analytes were detected. The relative recoveries of spiked water samples (at the 10 μg l^-1 level except for 2,6-DNT in 3 μg l^-1) were from 82.6 to 118.7%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Prosen, H., & Zupančič-Kralj, L. (1999) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(98)00109-5 · Cited by 565
Cited by
A new liquid-phase microextraction method based on solidification of floating organic drop
Khalili Zanjani, M. R., Yamini, Y., Shariati, S., & Jönsson, J. Å. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.12.049 · Cited by 512
Li, Y., Hu, J., Liu, X., Fu, L., Zhang, X., & Wang, X. (2008) · Journal of Separation Science · doi:10.1002/jssc.200800112 · Cited by 49
Sun, S.-H., Xie, J.-P., Xie, F.-W., & Zong, Y.-L. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.11.102 · Cited by 47
Metadata
- Authors
- Zhao, R., Chu, S., & Xu, X.
- Venue
- Analytical Sciences
- Published
- 2004-04
- Volume
- 20
- Issue
- 4
- Pages
- 663-666
- ISSN
- 0910-6340 (ISSN-L)
- 1348-2246
- OpenAlex
- W2030558820
- Cited by
- 35
- References
- 2
- FWCI
- 6.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimization of Nonequilibrium Liquid-Phase Microextraction for the Determination of Nitrobenzenes in Aqueous Samples by Gas Chromatography-Electron Capture Detection. https://app.cochat.ai/papers/10.2116/analsci.20.663
- The paper
- Zhao, R., Chu, S., & Xu, X. (2004). Optimization of Nonequilibrium Liquid-Phase Microextraction for the Determination of Nitrobenzenes in Aqueous Samples by Gas Chromatography-Electron Capture Detection. Analytical Sciences. https://doi.org/10.2116/analsci.20.663
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.