Cited by 82Smoking Behavior and CessationAnalytical chemistry methods developmentIndoor Air Quality and Microbial Exposure

Determination of Chemical Compounds Generated from Second-generation E-cigarettes Using a Sorbent Cartridge Followed by a Two-step Elution Method

Uchiyama, Shigehisa, Senoo, Yui, Hayashida, Hideki, Inaba, Yohei, Nakagome, Hideki, Kunugita, Naoki·2016·Analytical Sciences

Abstract

We developed an analytical method for analyzing electronic cigarette (E-cigarette) smoke, and measured the carbonyl compounds and volatile organic compounds generated by 10 brands of second-generation E-cigarettes. A glass filter (Cambridge filter pad) for particulate matter and a solid sorbent tube packed with Carboxen-572 for gaseous compounds were used to collect E-cigarette smoke. These were then analyzed using a two-step elution method with carbon disulfide and methanol, followed by high-performance liquid chromatography (HPLC) and gas chromatography mass spectrometry (GC/MS). Formaldehyde (FA), acetaldehyde (AA), acetone (AC), acrolein (ACR), propanal (PA), acetol (AT), glyoxal (GO), and methyl glyoxal (MGO) were detected by HPLC in some E-cigarettes. Propylene glycol (PG), glycerol (GLY), and some esters were detected by GC/MS. GO and MGO exist mainly as particulate matter. AA, AC, ACR, PA, and AT exist mainly as gaseous compounds. FA exists as both particulate matter and gaseous compounds. These carbonyl compounds have carbon numbers C1 - C3. The main components of E-liquid are PG (C3) and GLY (C3). Therefore, the oxidation of liquids, such as PG and GLY in E-cigarettes upon incidental contact with the heating element in E-cigarette, is suggested as being a possible cause for carbonyl generation. When the puff number exceeds a critical point, carbonyl generation rapidly increases and then remains constant. The results of this study are now being used to determine the following E-cigarette smoking protocol: puff volume, 55 mL; puff duration, 2 s; and puff number, 30. E-cigarette analysis revealed very large variation in carbonyl concentration among not only different brands, but also different samples of the same product. Typical distributions of carbonyl concentration were not observed in any of the E-cigarettes tested, and the mean values greatly differed from median values.

Integrity signals

Registry

Crossref · 10.2116/analsci.32.549

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Uchiyama, S., Senoo, Y., Hayashida, H., Inaba, Y., Nakagome, H., & Kunugita, N.
Affiliations
  • National Institute of Public Health (JP)
  • Chiba University (JP)
Corresponding author
Uchiyama, Shigehisa
Venue
Analytical Sciences
Published
2016-05
Volume
32
Issue
5
Pages
549-555
ISSN
  • 0910-6340 (ISSN-L)
  • 1348-2246
OpenAlex
W2346645822
Cited by
82
References
11
Citations by year
2026: 1 · 2025: 6 · 2024: 4 · 2023: 5 · 2022: 5 · 2021: 6 · 2020: 15 · 2019: 5 · 2018: 20 · 2017: 11 · 2016: 3
FWCI
10.45
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Sciences (publishedVersion)
  • PubMed (publishedVersion)
Funders
Japan Agency for Medical Research and Development
Topics
  • Health Sciences › Medicine › Physiology › Smoking Behavior and Cessation
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
Keywords
carbonyl compounds, volatile organic compounds, formaldehyde, acetaldehyde, acrolein, glyoxal, methylglyoxal, propylene glycol, glycerol, particulate matter, gaseous compounds
MeSH terms
Chemistry Techniques, Analytical, Molecular Structure, Volatile Organic Compounds, Electronic Nicotine Delivery Systems

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review