Water Irradiation Devoid Pulses Enhance the Sensitivity of 1H, 1H Nuclear Overhauser Effects
Open accessThe DOI matches its Crossref record; 43 of the 44 references it cites were found in a registry or an index, and 1 are not checked yet; 2 of the 33 sources its claims cite were checked for support.
Abstract
The nuclear Overhauser effect (NOE) is one of NMR spectroscopy's most important and versatile parameters. NOE is routinely utilized to determine the structures of medium-to-large size biomolecules and characterize protein-protein, protein-RNA, protein-DNA, and protein-ligand interactions in aqueous solutions. Typical [1H,1H] NOESY pulse sequences incorporate water suppression schemes to reduce the water signal that dominates 1H-detected spectra and minimize NOE intensity losses due to unwanted polarization exchange between water and labile protons. However, at high- and ultra-high magnetic fields, the excitation of the water signal during the execution of the NOESY pulse sequences may cause significant attenuation of NOE cross-peak intensities. Using an evolutionary algorithm coupled with artificial intelligence, we recently designed high-fidelity pulses [Water irrAdiation DEvoid (WADE) pulses] that elude water excitation and irradiate broader bandwidths relative to commonly used pulses. Here, we demonstrate that WADE pulses, implemented into the 2D [1H,1H] NOESY experiments, increase the intensity of the NOE cross-peaks for labile and, to a lesser extent, non-exchangeable protons. We applied the new 2D [1H,1H] WADE-NOESY pulse sequence to two well-folded, medium-size proteins, i.e., the K48C mutant of ubiquitin and the Raf kinase inhibitor protein (RKIP). We observed a net increase of the NOE intensities varying from 30 to 170% compared to the commonly used NOESY experiments. The new WADE pulses can be easily engineered into 2D and 3D homo- and hetero-nuclear NOESY pulse sequences to boost their sensitivity.
Verified 2026-11-20 · 1 reference not checked yet
Overview
CoChat Summary
TL;DR
WADE water-irradiation-devoid pulses (W1F90 and WR4) were incorporated into 2D [1H,1H] NOESY, increasing NOE cross-peak intensities for labile and, to a lesser extent, non-exchangeable protons in two proteins. Reported net NOE intensity gains ranged from 30 to 170% versus commonly used NOESY experiments.
Key findings
- The 2D [1H,1H] WADE-NOESY experiment increased NOE cross-peak intensities for labile and non-exchangeable protons, with a net increase varying from 30 to 170% compared to commonly used NOESY experiments.
- For UbiK48C, amide/amide–Hα cross-peaks were up to 54% more intense than in [1H,1H] ES-NOESY, and aliphatic-region resonances showed an overall increase of ~50%; NOE buildup followed typical kinetics with enhanced cross-peak intensities.
- Quantitative comparisons showed average cross-peak intensity gains of ~60% versus presat-NOESY, with the highest gain (>200%) for labile HN resonances; average sensitivity gains were 89% versus ES and 30% versus 3919 sequences.
- For RKIP, the WADE-NOESY spectrum contained substantially more NOE cross-peaks than ES-NOESY, especially at bandwidth edges and in the HN–HN region, where some cross-peaks were barely detectable with ES.
Methods
- W1F90 and WR4 WADE pulses were implemented into the standard 2D [1H,1H] NOESY sequence from the Bruker library (noesygpph19/noesyesgpph), replacing the third π/2 pulse and the WATERGATE 3919 water-suppression element; magnetization responses were simulated over a 20 kHz bandwidth while varying RF offset and B1 ±20%.
- NMR experiments used 15N-labeled UbiK48C (0.5 mM) and 15N-labeled RKIP (0.3 mM) on an 850 MHz Bruker Avance NEO with a TCI cryoprobe; ten mixing times were used: 25, 50, 75, 100, 150, 200, 300, 400, 500, and 700 ms, with 1024 points in the direct dimension and 256 complex points in the indirect dimension.
- Spectra were processed with NMRPipe using a sine bell window shifted by 90° and zero-filled to 1024×512; analyses compared 2D spectra, cross-sections, NOE buildup curves, and histograms of relative cross-peak intensities.
Limitations
- Not stated in the paper: the paper does not include an explicit limitations section.
- Evident from the text: experimental validation is limited to two medium-size proteins, UbiK48C and RKIP, at 850 MHz; no larger biomacromolecules or other magnetic field strengths are shown.
- Evident from the text: in UbiK48C, peaks near the water signal were weaker than in ES-NOESY unless the WADE pulse amplitude was lowered to 3.33 kHz, indicating a water-selectivity/bandwidth trade-off.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
2 Valid · 1 Not valid · 15 Not checked · 41 Own results and interpretations
Every source the paper cites for this claim was checked and supports it.
In the paper
“The WADE pulses used as a water-suppression sequence increase the sensitivity of the transverse relaxation optimized (TROSY) HSQC pulse sequence31.”
§ Water Irradiation Devoid Pulses Enhance the Sensitivity of 1H,1H Nuclear Overhauser Effects > Introduction
What the sources say
- Supportedcites [31] Manu VS, Olivieri C, Pavuluri K, Veglia G (2022) Design and applications of water irradiation devoid RF pulses for ultra-high field biomolecular NMR spectroscopy.Physical Chemistry Chemical Physics source
The paper states that the WADE-π pulse (WR1) replaces the conventional water-suppression element (e.g. 3-9-19) before acquisition, and that when the WADE pulses are implemented in the 2D [1H,15N]-TROSY-HSQC sequence the sensitivity increases (up to ~70.5% vs trosyetf3gpsi.2 and up to 60% vs trosyetf3gpsi2, the latter on perdeuterated PKA-C). The Conclusion and the discussion of the origin of the gain (higher fidelity of AR1/WR1 plus the efficiency of the WADE water suppression) directly back the paraphrase. Only caveat: the gain is credited jointly to the WADE water suppression and the replacement of the rectangular π pulses, not to water suppression alone. (LLM, conf=0.88)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Using GENETICS-AI, we generated broadband pulses (called WADE for Water irrAdiation DEvoid pulses) that elude water irradiation while exciting a large bandwidth at high-fidelity31.”
§ Water Irradiation Devoid Pulses Enhance the Sensitivity of 1H,1H Nuclear Overhauser Effects > Introduction
What the sources say
- Supportedcites [31] Manu VS, Olivieri C, Pavuluri K, Veglia G (2022) Design and applications of water irradiation devoid RF pulses for ultra-high field biomolecular NMR spectroscopy.Physical Chemistry Chemical Physics source
The Abstract of our copy states that GENETICS-AI (GENErator of TrIply Compensated pulSes via Artificial Intelligence) was used to design high-fidelity RF pulses that completely elude excitation of the water signal, and defines the WADE acronym (Water irrAdiation DEvoid). The same sections describe their broadband character (e.g. WR3 exciting up to 50 ppm with uncompromised operational fidelity, and superior bandwidth versus 3-9-19/W5), matching every element the citing sentence attributes to this source. (LLM, conf=0.93)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“We show that the intensities of the NOESY cross-peaks follow the typical kinetics of the NOE buildup, with an increase of the cross-peak intensities ranging from 30 to 170%.”
- Also stated in: another passage · plain
“From the selected residues, it is possible to appreciate the typical kinetics of the NOE buildup and the significant enhancement of the NOE cross peaks intensities relative to the [1H,1H] ES-NOESY spectra.”
§ Water Irradiation Devoid Pulses Enhance the Sensitivity of 1H,1H Nuclear Overhauser Effects > Introduction
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: another passage · plain
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The peaks of the [1H,1H] WADE-NOESY spectrum are negative in the range of chemical shifts from −1.0 to 4.7 ppm and positive from 4.7 to 10 ppm, according to the W1F90 pulse excitation profile of Figure 5.”
§ Water Irradiation Devoid Pulses Enhance the Sensitivity of 1H,1H Nuclear Overhauser Effects > Results and Discussion
plainSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“We observed a net increase of the NOE intensities varying from 30 to 170% compared to the commonly used NOESY”
- Also stated in: another passage · plain
“We show that the intensities of the NOESY cross-peaks follow the typical kinetics of the NOE buildup, with an increase of the cross-peak intensities ranging from 30 to 170%.”
§ Water Irradiation Devoid Pulses Enhance the Sensitivity of 1H,1H Nuclear Overhauser Effects > Abstract
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: another passage · plain
21 more claims
Create a free account to see all 59 claims and to verify the 29 references still open.
- It may state two separate claims as one. 18
- Probably not a substantial claim. 19
- The quote only partly states this claim. 1
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
“We observed a net increase of the NOE intensities varying from 30 to 170% compared to the commonly used NOESY experiments.”
“The highest gain (>200%) is achieved for labile HN resonances that broaden out partially or entirely due to the exchange with the water signal caused by the weak RF field used in the presaturation sequence.”
Citations
Cites
NMRPipe: A multidimensional spectral processing system based on UNIX pipes
Delaglio, F., Grzesiek, S., Vuister, G., Zhu, G., Pfeifer, J., & Bax, A. (1995) · Journal of Biomolecular NMR · doi:10.1007/bf00197809 · Cited by 15,965
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
NMR with Proteins and Nucleic Acids
Wüthrich, K. (1986) · Europhysics News · doi:10.1051/epn/19861701011 · Cited by 7,989
Gradient-tailored excitation for single-quantum NMR spectroscopy of aqueous solutions
Piotto, M., Saudek, V., & Sklenář, V. (1992) · Journal of Biomolecular NMR · doi:10.1007/bf02192855 · Cited by 3,712
Pervushin, K., Riek, R., Wider, G., & Wüthrich, K. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.23.12366 · Cited by 2,445
Kumar, A., Ernst, R. R., & Wüthrich, K. (1980) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(80)90695-6 · Cited by 1,905
Hwang, T. L., & Shaka, A. J. (1995) · Journal of Magnetic Resonance, Series A · doi:10.1006/jmra.1995.1047 · Cited by 1,898
Polarization of Nuclei in Metals
Overhauser, A. W. (1953) · Physical Review · doi:10.1103/physrev.92.411 · Cited by 1,710
Gradient-Tailored Water Suppression for 1H-15N HSQC Experiments Optimized to Retain Full Sensitivity
Sklenar, V., Piotto, M., Leppik, R., & Saudek, V. (1993) · Journal of Magnetic Resonance, Series A · doi:10.1006/jmra.1993.1098 · Cited by 1,159
Grzesiek, S., & Bax, A. (1993) · Journal of the American Chemical Society · doi:10.1021/ja00079a052 · Cited by 881
Cited by
Zhan, H., Huang, Y., & Chen, Z. (2026) · Applied Physics Reviews · doi:10.1063/5.0277355 · Cited by 22
Evolutionary Computation in bioinformatics: A survey
Zhang, Y., Li, C., Chen, G., & Alghazzawi, D. (2024) · Neurocomputing · doi:10.1016/j.neucom.2024.127758 · Cited by 18
Pellizzari, J., Soong, R., Downey, K., Biswas, R. G., Kock, F. V. C., Steiner, K., Goerling, B., Haber, A., Decker, V., Busse, F., et al. (2024) · Magnetic Resonance in Chemistry · doi:10.1002/mrc.5431 · Cited by 8
Tokarz, P. (2024) · Scientiae Radices · doi:10.58332/scirad2024v3i1a04 · Cited by 7
Subrahmanian, M. V., & Veglia, G. (2024) · Chemical Communications · doi:10.1039/d3cc05370a · Cited by 5
Self-citation
Metadata
- Authors
- Subrahmanian, M. V., Olivieri, C., & Veglia, G.
- Affiliations
- University of Minnesota (US)
- Corresponding author
- Veglia, Gianluigi
- Venue
- Journal of Biomolecular NMR
- Publisher
- Research Square Platform LLC
- Published
- 2022-09-01
- Volume
- 77
- Issue
- 1-2
- Pages
- 1-14
- ISSN
- 0925-2738 (ISSN-L)
- PMC
- PMC11457533
- OpenAlex
- W4311932963
- Cited by
- 12
- References
- 43
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 5 · 2023: 1
- FWCI
- 0.78
- Type
- journal article
- Language
- en
- Open access
- green
- doi.org
- Locations
- Journal of Biomolecular NMR (publishedVersion)
- Research Square (submittedVersion, cc-by)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- University of Minnesota
- National Institutes of Health
- National Heart, Lung, and Blood Institute (R01HL144130)
- National Institute of General Medical Sciences (R01GM121735)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein Structure and Dynamics
- Physical Sciences › Chemistry › Spectroscopy › Molecular spectroscopy and chirality
- Keywords
- nuclear Overhauser effect, NOESY, water irradiation, water suppression, high-field NMR, pulse sequence design, RKIP, protein structure determination
- MeSH terms
- Artificial Intelligence, Proteins, Protons, Water, Nuclear Magnetic Resonance, Biomolecular
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-18, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-18 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Water Irradiation Devoid Pulses Enhance the Sensitivity of 1H, 1H Nuclear Overhauser Effects. https://app.cochat.ai/papers/10.21203/rs.3.rs-2010749/v1
- The paper
- Subrahmanian, M. V., Olivieri, C., & Veglia, G. (2022). Water Irradiation Devoid Pulses Enhance the Sensitivity of 1H, 1H Nuclear Overhauser Effects. Journal of Biomolecular NMR. https://doi.org/10.21203/rs.3.rs-2010749/v1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.