Orifice surface temperature measurement of a LaB 6 hollow cathode using a near-infrared two-color radiation thermometer
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
This study measured the two-dimensional orifice surface temperature of a 20-A-class LaB 6 hollow cathode using a near-infrared two-color radiation thermometer. The thermometer technique resolved the orifice plate temperature with an accuracy of approximately 123 ℃. With this technique, the surface temperature of the orifice was found nearly uniform, with no observed temperature gradient on the orifice plate. Consequently, the operational characteristics of the hollow cathode are discussed in relation to the average surface temperature. Data analysis revealed that the orifice temperature was not sensitive to the mass flow rate; conversely, it was highly sensitive to the discharge current. The findings suggest that the orifice temperature is unaffected by internal pressure but is instead correlated with the insert temperature, which is related to the thermionic emission necessary to sustain the discharge current. Moreover, for the same input power, the orifice temperature was higher in the high-current, low-voltage mode—also known as the spot mode—indicating efficient emitter heating. The measurement system developed in this study provides a more precise evaluation of the orifice temperature and allows for estimating the internal conditions of a hollow cathode, thus facilitating more appropriate design evaluations under various operating conditions.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
A numerical study of low-frequency discharge oscillations in Hall thrusters
Fife, J., Martínez-Sánchez, M., & Szabo, J. (1997) · AIAA/ASME/SAE/ASEE Joint Propulsion Conference and Exhibit · doi:10.2514/6.1997-3052 · Cited by 158
LaB6 Hollow Cathodes for Ion and Hall Thrusters
Goebel, D. M., Watkins, R. M., & Jameson, K. K. (2007) · Journal of Propulsion and Power · doi:10.2514/1.25475 · Cited by 143
16th International Electric Propulsion Conference
(1982) · doi:10.2514/miep82 · Cited by 140
Recent progress in research and development of hollow cathodes for electric propulsion
Lev, D. R., Mikellides, I. G., Pedrini, D., Goebel, D. M., Jorns, B., & McDonald, M. (2019) · Reviews of Modern Plasma Physics · doi:10.1007/s41614-019-0026-0 · Cited by 126
Future Directions for Electric Propulsion Research
Dale, E., Jorns, B., & Gallimore, A. (2020) · Aerospace · doi:10.3390/aerospace7090120 · Cited by 95
High-Current Lanthanum Hexaboride Hollow Cathode for High-Power Hall Thrusters
Goebel, D. M., & Chu, E. (2014) · Journal of Propulsion and Power · doi:10.2514/1.b34870 · Cited by 82
The measurement of metal droplet temperature in GMA welding by infrared two-colour pyrometry
Yamazaki, K., Yamamoto, E., Suzuki, K., Koshiishi, F., Waki, K., Tashiro, S., Tanaka, M., & Nakata, K. (2010) · Welding International · doi:10.1080/09507110902842950 · Cited by 50
Temperature Distributions in Hollow Cathode Emitters
Polk, J., Marrese, C., Dang, L., Johnson, L., & Thornber, B. (2004) · 40th AIAA/ASME/SAE/ASEE Joint Propulsion Conference and Exhibit · doi:10.2514/6.2004-4116 · Cited by 50
Low-current hollow cathode evaluation
Domonkos, M., Gallimore, A. D., Williams, G. J., III, & Patterson, M. (1999) · AIAA/ASME/SAE/ASEE Joint Propulsion Conference and Exhibit · doi:10.2514/6.1999-2575 · Cited by 39
Review of High-Power Electrostatic and Electrothermal Electric Propulsion
Jovel, D. R., Walker, M. L. R., & Herman, D. (2022) · Journal of Propulsion and Power · doi:10.2514/1.b38594 · Cited by 38
Insert Heating and Ignition in Inert-Gas Hollow Cathodes
Katz, I. M., Mikellides, I. G., Goebel, D. M., & Polk, J. E. (2008) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2008.2004363 · Cited by 27
500-A LaB6 Hollow cathode for high power electric thrusters
Becatti, G., & Goebel, D. M. (2022) · Vacuum · doi:10.1016/j.vacuum.2022.110895 · Cited by 24
Low-Current, Xenon Orificed Hollow Cathode Performance for In-Space Applications
Domonkos, M., Patterson, M., & Gallimore, A. D. (2003) · Journal of Propulsion and Power · doi:10.2514/2.6127 · Cited by 23
Scanning optical pyrometer for measuring temperatures in hollow cathodes
Polk, J. E., Marrese-Reading, C. M., Thornber, B., Dang, L., Johnson, L., & Katz, I. M. (2007) · Review of Scientific Instruments · doi:10.1063/1.2774828 · Cited by 22
Operation of a Hollow Cathode Neutralizer for Sub-100-W Hall and Ion Thrusters
Lev, D. R., & Alon, G. (2017) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2017.2779409 · Cited by 20
SITAEL HC1 Low-Current Hollow Cathode
Pedrini, D., Ducci, C., Cesari, U., Misuri, T., & Andrenucci, M. (2020) · Aerospace · doi:10.3390/aerospace7070096 · Cited by 16
The effect of facility background pressure on hollow cathode operation
Hall, S. J., Gray, T. G., Yim, J., Choi, M., Sarver-Verhey, T. R., & Kamhawi, H. (2021) · Journal of Applied Physics · doi:10.1063/5.0061045 · Cited by 11
Oshio, Y., Tauchi, S., Kawasaki, A., & Funaki, I. (2021) · Journal of Applied Physics · doi:10.1063/5.0063942 · Cited by 8
Self-citationInfluence of heating on the discharge characteristics of a hollow cathode
Hu, Y., Ning, Z., Liu, X., Chu, Y., Wei, M., Shen, Y. R., & Zhu, X.-M. (2019) · Plasma Science and Technology · doi:10.1088/2058-6272/ab472a · Cited by 7
The Effect of Anode Configuration on the Plasma Plume of a 25-A class Hollow Cathode
Hall, S. J., Gray, T. G., Sarver-Verhey, T. R., & Kamhawi, H. (2021) · AIAA Propulsion and Energy Forum · doi:10.2514/6.2021-3376 · Cited by 7
Hollow Cathode Studies for the Next Generation Ion Engines in JAXA
Ohkawa, Y., Hayakawa, Y., Yoshida, H., Miyazaki, K., KITAMURA, S., & Kajiwara, K. (2009) · TRANSACTIONS OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES SPACE TECHNOLOGY JAPAN · doi:10.2322/tstj.7.pb_23 · Cited by 3
Research works printed but not linked: 2
- Mazouffre S, Joussot R, Vincent B, Tsikata S, Oriol S, Masson F (2019) Characterization of a 100 A-class LaB6 hollow cathode for high-power Hall thrusters. In 36th International Electric Propulsion Conference
- Noord JV, Kamhawi H, McEwen HK (2005) Characterization of a high current, long life hollow cathode. In 29th International Electric Propulsion Conference
Cited by
Martens, P. D., Barton, D. A. W., Schartner, A. P., Charles, C., & Boswell, R. W. (2025) · Journal of Electric Propulsion · doi:10.1007/s44205-025-00115-3 · Cited by 4
Self-citationCho, S., Watanabe, H., Matsunaga, Y., & Ohkawa, Y. (2025) · Journal of Applied Physics · doi:10.1063/5.0288202 · Cited by 2
Self-citationYamashita, Y., Butler-Craig, N. I., Walker, M. L. R., & Hara, K. (2026) · Journal of Applied Physics · doi:10.1063/5.0316910
Metadata
- Authors
- Oshio, Y., Hirai, K., Watanabe, H., Horisawa, H., & Funaki, I.
- Affiliations
- Ryukoku University (JP)
- Tokai University (JP)
- Japan Aerospace Exploration Agency (JP)
- Venue
- Research Square
- Published
- 2024-11-27
- OpenAlex
- W4404771882
- Cited by
- 1
- References
- 21
- Citations by year
- 2025: 1
- Type
- posted content
- Language
- en
- Open access
- green
- dx.doi.org
- Locations
- Research Square (acceptedVersion, cc-by)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Low-Pressure Plasma Processing and Diagnostics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Vacuum and Plasma Arcs
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Gyrotron and Vacuum Electronics Research
- Keywords
- thermionic emission, discharge current, mass flow rate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.