The Use of Ultrasound for Placement of Intravenous Catheters
The DOI matches its Crossref record.
Abstract
Ultrasound has been used to aid cannulation of veins of the neck, chest, antecubital fossa, and femoral vein. This investigation compared the traditional method of peripheral intravenous (IV) cannulation of veins of the hands and forearms with ultrasound-guided IV cannulation of these veins. After obtaining institutional review board approval and written informed consent, 35 adult subjects with a history or suspicion of difficult IV cannulation were prospectively enrolled with 16 subjects randomly assigned to the traditional group and 19 to the ultrasound group. Time taken for successful venous cannulation and number of attempts between the groups were compared using a Mann-Whitney U test. The number of subjects in whom IV cannulation was successful on the first attempt was compared between the groups using the Fisher exact test. No significant differences were noted between groups in demographics, time to successful cannulation, number of attempts, and number of subjects in whom IV cannulation was successful on the first attempt. Ultrasound was as efficacious as the traditional method of IV cannulation in this subset of patients. Future investigations should examine the efficacy of the ultrasound-guided technique of IV cannulation of these veins in patients in whom the traditional method failed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Accepted but Unacceptable: Peripheral IV Catheter Failure
Helm, R. E., Klausner, J. D., Klemperer, J. D., Flint, L. M., & Huang, E. (2015) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000100 · Cited by 445
Lamperti, M., Biasucci, D. G., Disma, N., Pittiruti, M., Breschan, C., Vailati, D., Subert, M., Traškaitė, V., Macas, A., Estebe, J.-P., et al. (2020) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000001180 · Cited by 316
Ultrasound guidance for difficult peripheral venous access: Systematic review and meta-analysis
Egan, G., Healy, D., O'Neill, H., Clarke-Moloney, M., Grace, P. A., & Walsh, S. R. (2013) · Emergency Medicine Journal · doi:10.1136/emermed-2012-201652 · Cited by 222
van Loon, F. H. J., Buise, M. P., Claassen, J. J. F., Dierick-van Daele, A. T. M., & Bouwman, A. R. A. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2018.04.047 · Cited by 195
Ultrasound-guided peripheral venous access: A meta-analysis and systematic review
Stolz, L. A., Stolz, U., Howe, C., Farrell, I. J., & Adhikari, S. (2015) · The Journal of Vascular Access · doi:10.5301/jva.5000346 · Cited by 189
Metadata
- Authors
- Acosta, S.
- Publisher
- Defense Technical Information Center
- Published
- 2004-12-13
- Volume
- 75
- Issue
- 3
- Pages
- 212-6
- OpenAlex
- W1860516050
- Cited by
- 60
- References
- 0
- Type
- report
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Use of Ultrasound for Placement of Intravenous Catheters. https://app.cochat.ai/papers/10.21236/ada428738
- The paper
- Acosta, S. (2004). The Use of Ultrasound for Placement of Intravenous Catheters. https://doi.org/10.21236/ada428738
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.