The DOI matches its Crossref record.
Screening Indoor Plants for Volatile Organic Pollutant Removal Efficiency
Open accessAbstract
Twenty-eight ornamental species commonly used for interior plantscapes were screened for their ability to remove five volatile indoor pollutants: aromatic hydrocarbons (benzene and toluene), aliphatic hydrocarbon (octane), halogenated hydrocarbon [trichloroethylene (TCE)], and terpene ( α -pinene). Individual plants were placed in 10.5-L gas-tight glass jars and exposed to ≈10 ppm (31.9, 53.7, 37.7, 46.7, and 55.7 mg·m −3 ) of benzene, TCE, toluene, octane, and α -pinene, respectively. Air samples (1.0 mL) within the glass containers were analyzed by gas chromatography–mass spectroscopy 3 and 6 h after exposure to the test pollutants to determine removal efficiency by monitoring the decline in concentration over 6 h within sealed glass containers. To determine removal by the plant, removal by other means (glass, plant pot, media) was subtracted. The removal efficiency, expressed on a leaf area basis for each volatile organic compound (VOC), varied with plant species. Of the 28 species tested, Hemigraphis alternata , Hedera helix , Hoya carnosa , and Asparagus densiflorus had the highest removal efficiencies for all pollutants; Tradescantia pallida displayed superior removal efficiency for four of the five VOCs (i.e., benzene, toluene, TCE, and α -pinene). The five species ranged in their removal efficiency from 26.08 to 44.04 μg·m −3 ·m −2 ·h −1 of the total VOCs. Fittonia argyroneura effectively removed benzene, toluene, and TCE. Ficus benjamina effectively removed octane and α -pinene, whereas Polyscias fruticosa effectively removed octane. The variation in removal efficiency among species indicates that for maximum improvement of indoor air quality, multiple species are needed. The number and type of plants should be tailored to the type of VOCs present and their rates of emanation at each specific indoor location.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A state–of–the-art review on indoor air pollution and strategies for indoor air pollution control
González-Martín, J., Kraakman, N. J. R., Pérez, C., Lebrero, R., & Muñoz, R. (2021) · Chemosphere · doi:10.1016/j.chemosphere.2020.128376 · Cited by 562
A review on phytoremediation of contaminants in air, water and soil
Wei, Z., Van Le, Q., Peng, W., Yang, Y., Yang, H., Gu, H., Lam, S. S., & Sonne, C. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2020.123658 · Cited by 419
Irga, P. J., Torpy, F. R., & Burchett, M. D. (2013) · Atmospheric Environment · doi:10.1016/j.atmosenv.2013.04.078 · Cited by 137
Cummings, B. E., & Waring, M. S. (2020) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-019-0175-9 · Cited by 98
Metadata
- Authors
- Yang, D. S., Pennisi, S. V., Son, K.-C., & Kays, S. J.
- Venue
- HortScience
- Published
- 2009-08
- Volume
- 44
- Issue
- 5
- Pages
- 1377-1381
- ISSN
- 0018-5345 (ISSN-L)
- 2327-9834
- OpenAlex
- W1947507490
- Cited by
- 194
- References
- 0
- FWCI
- 2.91
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Screening Indoor Plants for Volatile Organic Pollutant Removal Efficiency. https://app.cochat.ai/papers/10.21273/hortsci.44.5.1377
- The paper
- Yang, D. S., Pennisi, S. V., Son, K.-C., & Kays, S. J. (2009). Screening Indoor Plants for Volatile Organic Pollutant Removal Efficiency. HortScience. https://doi.org/10.21273/hortsci.44.5.1377
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.