Biological Selenium Volatilization: Method of Measurement under Field Conditions
The DOI matches its Crossref record.
Abstract
An open‐flow chamber sampling system was developed for measurements of selenium (Se) volatilization from soil and vegetated areas under field conditions. This paper provides detailed information on the design, construction, and calibration of the chamber sampling system. Volatile Se was collected using a Plexiglas collection chamber, 0.71 m long, 0.71 m wide, and 0.76 in high; the chamber provided an internal volume of 0.38 m 3 and enclosed a ground area of 0.5 m 2. Volatile Se produced inside the collection chamber was trapped by activated carbon filters from the air leaving the chamber. The trapped Se was extracted from the charcoal filters in alkaline‐peroxide solution. The system has a maximum measurement capacity of 10 mg Se m−2 over a sampling period of 24 h at an air flow rate of 0.43 m 3 h−1. Measurements of Se volatilization from the soil‐halophyte system in central California were carried out to demonstrate the efficiency of this sampling system under field conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Selenium Cycling Across Soil-Plant-Atmosphere Interfaces: A Critical Review
Winkel, L., Vriens, B., Jones, G., Schneider, L., Pilon-Smits, E., & Bañuelos, G. (2015) · Nutrients · doi:10.3390/nu7064199 · Cited by 476
“1999) [273] 117–125 μg Se·m−2·d−1 Field No Soil 4–8 mg·kg−1”
Bañuelos, G., Terry, N., LeDuc, D. L., Pilon-Smits, E. A. H., & Mackey, B. (2005) · Environmental Science & Technology · doi:10.1021/es049035f · Cited by 226
Self-citationPhytoremediation of Organomercurial Compounds via Chloroplast Genetic Engineering
Ruiz, O. N., Hussein, H. S., Terry, N., & Daniell, H. (2003) · Plant Physiology · doi:10.1104/pp.103.020958 · Cited by 224
“An alternative and more costeffective approach is phytoremediation, i.e. the use of plants to clean up contaminated environments (Lin et al., 1995; Salt et al., 1995; Terry et al., 2000).”
BackgroundSelf-citationBañuelos, G. S., Lin, Z.-Q., Arroyo, I., & Terry, N. (2005) · Chemosphere · doi:10.1016/j.chemosphere.2005.02.033 · Cited by 61
Self-citationLin, Z. (2002) · Water Research · doi:10.1016/s0043-1354(02)00007-6 · Cited by 53
“[30], including optimization of sampling efficiency and capacity using DMSe standard, as well as a comparison of temperature, humidity, photosynthetically active radiation, and air pressure between the inside and outside of the chamber.”
MethodSelf-citationBañuelos, G. S., & Lin, Z.-Q. (2007) · Environmental Pollution · doi:10.1016/j.envpol.2007.02.009 · Cited by 42
“Briefly, the chambers used for volatile Se collection were made of 6.6-mm thick Plexiglas and had dimensions of 0.71 m long, 0.71 m wide and 0.76 m high, as described in detail by Lin et al. (1999).”
MethodInfluentialSelf-citation
Metadata
- Authors
- Lin, Z. ‐., Hansen, D., Zayed, A., & Terry, N.
- Venue
- Journal of Environmental Quality
- Publisher
- Wiley
- Published
- 1999-01
- Volume
- 28
- Issue
- 1
- Pages
- 309-315
- ISSN
- 0047-2425 (ISSN-L)
- 1537-2537
- OpenAlex
- W2028121892
- Cited by
- 28
- References
- 0
- FWCI
- 1.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.