Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 893

The DOI matches its Crossref record.

The LightCycler TM : A Microvolume Multisample Fluorimeter with Rapid Temperature Control

Open access
Wittwer, C.T., Ririe, K.M., Andrew, R.V., David, D.A., Gundry, R.A., Balis, U.J.·1997·BioTechniques

Abstract

Experimental and commercial microvolume fluorimeters with rapid temperature control are described. Fluorescence optics adopted from flow cytometry were used to interrogate 1-10-microL samples in glass capillaries. Homogeneous temperature control and rapid change of sample temperatures (10 degrees C/s) were obtained by a circulating air vortex. A prototype 2-color, 32-sample version was constructed with a xenon arc for excitation, separate excitation and emission paths, and photomultiplier tubes for detection. The commercial LightCycler, a 3-color, 24-sample instrument, uses a blue light-emitting diode for excitation, paraxial epi-illumination through the capillary tip and photodiodes for detection. Applications include analyte quantification and nucleic acid melting curves with fluorescent dyes, enzyme assays with fluorescent substrates and techniques that use fluorescence resonance energy transfer. Microvolume capability allows analysis of very small or expensive samples. As an example of one application, rapid cycle DNA amplification was continuously monitored by three different fluorescence techniques, Which included using the double-stranded DNA dye SYBR Green I, a dual-labeled 5'-exonuclease hydrolysis probe, and adjacent fluorescein and Cy5z-labeled hybridization probes. Complete amplification and analysis requires only 10-15 min.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2144/97221pf02

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 893

Metadata

Authors
Wittwer, C. T., Ririe, K. M., Andrew, R. V., David, D. A., Gundry, R. A., & Balis, U. J.
Venue
BioTechniques
Published
1997-01
Volume
22
Issue
1
Pages
176-181
ISSN
  • 0736-6205 (ISSN-L)
  • 1940-9818
OpenAlex
W1569947224
Cited by
893
References
0
FWCI
38.18
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The LightCycler TM : A Microvolume Multisample Fluorimeter with Rapid Temperature Control. https://app.cochat.ai/papers/10.2144/97221pf02
The paper
Wittwer, C. T., Ririe, K. M., Andrew, R. V., David, D. A., Gundry, R. A., & Balis, U. J. (1997). The LightCycler TM : A Microvolume Multisample Fluorimeter with Rapid Temperature Control. BioTechniques. https://doi.org/10.2144/97221pf02

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.