Intracellular Magnetic Labeling of Lymphocytes for In Vivo Trafficking Studies
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Lymphocyte adhesion and trafficking is difficult to observe in vivo over time. We used magnetic resonance imaging (MRI) to identify magnetically labeled lymphocytes in phantom experiments and in tissue. A method of lymphocyte labeling was developed that is based on fluid-phase endocytosis of nanometer-sized biocompatible superparamagnetic particles. The maximum cell uptake in culture was 0.11 ng Fe/cell corresponding to 5 x 10(6) particles/lymphocyte. Cells stably retained the label and were fully viable for at least 3 days. Labeled lymphocytes showed adhesion to human endothelial cells similar to unlabeled cells, indicating no effect of labeling on cell surface expression of adhesion proteins. No particle-mediated cytotoxicity could be observed. The detection threshold of MRI for detecting labeled lymphocytes in the current study was 2.5 x 10(6) cells/30 microL sampling volume. Following intravenous injection of labeled lymphocytes into rats, cells accumulated in spleen, lymph nodes and liver with a similar bio-distribution as unlabeled cells. Lymphocyte accumulation in the spleen resulted in MRI signal intensity changes readily detectable by MRI. These findings suggest that intracellular lymphocyte labeling with superparamagnetic particles is feasible, does not alter the viability or tissue distribution of labeled cells and allows the detection of labeled lymphocytes by MRI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rabinowitz, S., Horstmann, H., Gordon, S., & Griffiths, G. (1992) · The Journal of Cell Biology · doi:10.1083/jcb.116.1.95 · Cited by 271
Cited by
Synthesis and surface engineering of iron oxide nanoparticles for biomedical applications
Gupta, A. K., & Gupta, M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.10.012 · Cited by 6,771
Lewin, M., Carlesso, N., Tung, C.-H., Tang, X.-W., Cory, D., Scadden, D. T., & Weissleder, R. (2000) · Nature Biotechnology · doi:10.1038/74464 · Cited by 1,716
Self-citationFunctionalisation of magnetic nanoparticles for applications in biomedicine
Berry, C. C., & Curtis, A. S. G. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/203 · Cited by 1,588
Iron oxide MR contrast agents for molecular and cellular imaging
Bulte, J. W. M., & Kraitchman, D. L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.924 · Cited by 1,500
Surface modification of superparamagnetic magnetite nanoparticles and their intracellular uptake
Zhang, Y., Kohler, N., & Zhang, M. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00267-8 · Cited by 1,264
In vivo magnetic resonance imaging of transgene expression
Weissleder, R., Moore, A., Mahmood, U., Bhorade, R., Benveniste, H., Chiocca, E. A., & Basilion, J. P. (2000) · Nature Medicine · doi:10.1038/73219 · Cited by 776
Self-citationBulte, J. W. M., Zhang, S.-C., van Gelderen, P., Herynek, V., Jordan, E. K., Duncan, I. D., & Frank, J. A. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.26.15256 · Cited by 531
Magnetic Iron Oxide Nanoparticle (IONP) Synthesis to Applications: Present and Future
Ajinkya, N., Yu, X., Kaithal, P., Luo, H., Somani, P., & Ramakrishna, S. (2020) · Materials · doi:10.3390/ma13204644 · Cited by 362
Molecular Imaging: Exploring the Next Frontier
Weissleder, R. (1999) · Radiology · doi:10.1148/radiology.212.3.r99se18609 · Cited by 339
Self-citationGupta, A. K., & Curtis, A. S. G. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.095 · Cited by 302
Huang, D., Hung, Y., Ko, B., Hsu, S., Chen, W., Chien, C., Tsai, C., Kuo, C., Kang, J., Yang, C., et al. (2005) · The FASEB Journal · doi:10.1096/fj.05-4288fje · Cited by 289
In Vivo Magnetic Resonance Tracking of Magnetically Labeled Cells after Transplantation
Bulte, J. W. M., Duncan, I. D., & Frank, J. A. (2002) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200208000-00001 · Cited by 288
Zhang, J., Rana, S., Srivastava, R. S., & Misra, R. D. K. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.06.006 · Cited by 277
YUAN, H., MIAO, J., DU, Y., YOU, J., HU, F., & ZENG, S. (2008) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2007.07.012 · Cited by 275
Gholamrezanezhad, A., Mirpour, S., Bagheri, M., Mohamadnejad, M., Alimoghaddam, K., Abdolahzadeh, L., Saghari, M., & Malekzadeh, R. (2011) · Nuclear Medicine and Biology · doi:10.1016/j.nucmedbio.2011.03.008 · Cited by 266
“[25] asserted that with clinical 1.”
Detection of Single Mammalian Cells by High-Resolution Magnetic Resonance Imaging
Dodd, S. J., Williams, M., Suhan, J. P., Williams, D. S., Koretsky, A. P., & Ho, C. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77182-1 · Cited by 265
Stroh, A., Zimmer, C., Gutzeit, C., Jakstadt, M., Marschinke, F., Jung, T., Pilgrimm, H., & Grune, T. (2004) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2004.01.016 · Cited by 202
“Several different strategies have been developed or postulated for the successful transport of VSOPs to the appropriate organs in vivo [18,19].”
BackgroundTargeting of Hematopoietic Progenitor Cells with MR Contrast Agents
Daldrup-Link, H. E., Rudelius, M., Oostendorp, R. A. J., Settles, M., Piontek, G., Metz, S., Rosenbrock, H., Keller, U., Heinzmann, U., Rummeny, E. J., et al. (2003) · Radiology · doi:10.1148/radiol.2283020322 · Cited by 200
Dave, S. R., & Gao, X. (2009) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.51 · Cited by 200
Preparation of Magnetically Labeled Cells for Cell Tracking by Magnetic Resonance Imaging
Bulte, J. W. M., Arbab, A. S., Douglas, T., & Frank, J. A. (2004) · Methods in Enzymology · doi:10.1016/s0076-6879(04)86013-0 · Cited by 175
Daldrup-Link, H. E., Rudelius, M., Piontek, G., Metz, S., Bräuer, R., Debus, G., Corot, C., Schlegel, J., Link, T. M., Peschel, C., et al. (2005) · Radiology · doi:10.1148/radiol.2341031236 · Cited by 170
Ahrens, E. T., Feili‐Hariri, M., Xu, H., Genove, G., & Morel, P. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10465 · Cited by 168
“Cytotoxicity and cell adhesion studies of SPIO-loaded T-cells show no adverse effects after in vitro labeling (17).”
BackgroundDaldrup-Link, H. E., Meier, R., Rudelius, M., Piontek, G., Piert, M., Metz, S., Settles, M., Uherek, C., Wels, W., Schlegel, J., et al. (2005) · European Radiology · doi:10.1007/s00330-004-2526-7 · Cited by 167
“Such optimized labeling methods have been developed before for various hematopoietic cell populations, including lymphocytes, monocytes and hematopoietc progenitor cells (17, 20-26).”
BackgroundMethodLo, C.-L., Lin, K.-M., & Hsiue, G.-H. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.03.004 · Cited by 159
MRI confirms loss of blood–brain barrier integrity in a mouse model of disseminated candidiasis
Navarathna, D. H. M. L. P., Munasinghe, J., Lizak, M. J., Nayak, D., McGavern, D. B., & Roberts, D. D. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2926 · Cited by 34
“Cellular infiltration associated with inflammation was visualized by MRI, 24 h following intravenous injection of USPIO (32,33).”
Background
Metadata
- Authors
- Schoepf, U., Marecos, E. M., Melder, R. J., Jain, R. K., & Weissleder, R.
- Venue
- BioTechniques
- Publisher
- Informa UK Limited
- Published
- 1998-04
- Volume
- 24
- Issue
- 4
- Pages
- 642-651
- ISSN
- 0736-6205 (ISSN-L)
- 1940-9818
- OpenAlex
- W1591778519
- Cited by
- 133
- References
- 1
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.