CoChat

Association between echo intensity and attenuation of skeletal muscle in young and older adults: a comparison between ultrasonography and computed tomography

Open access
Watanabe, Yuya, Ikenaga, Masahiro, Yoshimura, Eiichi, Yamada, Yosuke, Kimura, Misaka · 2018 · Clinical Interventions in Aging
Cited by 72

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Background: Skeletal muscle experiences both quantitative and qualitative changes with aging. Echo intensity (EI) of the skeletal muscle obtained by ultrasonography (US) has been considered to reflect muscle quality. This technique is noninvasive, easily accessible, and is relatively inexpensive than that of other imaging techniques such as computed tomography (CT). Previous studies have reported that EI is related to several physical performances. However, few studies have investigated the validity of EI against other imaging methods in case of imaging of the skeletal muscle. We compared quantitative and qualitative indices evaluated by the US and CT imaging systems to strengthen their validity. Participants and methods: A total of 40 adults participated in this study: 19 young (10 men and 9 women; their mean (±SD) age was 22.7±1.5 years) and 21 older adults (13 men and 8 women; their mean age was 70.6±4.8 years). Both thighs of each participant were evaluated using US and CT imaging systems. Results: With respect to the US indices, the young group had significantly higher muscle thickness (MT) of the front thigh ( P <0.001) and lower EI ( P =0.001) than that of the older group. With respect to the CT indices, the cross-sectional area (CSA) and mean CT value (Hounsfield unit [HU]) of the muscle were found to be significantly higher in the young group ( P <0.001) than that of the older group, whereas the percentage of low-density muscle area (%LDMA) was found to be significantly higher in the older group ( P <0.001) than that of the young group. A significant, strong, and positive correlation was observed between MT and CSA, which reflects the muscle quantity ( r =0.774; P <0.001). With respect to the indices of muscle quality, we found significant and moderate correlations between EI and CT values ( r =-0.502; P <0.001) and between EI and %LDMA ( r =0.441; P <0.001). However, these correlations were found to be decreased in the older group [between EI and CT value ( r =-0.363; P =0.018) and between EI and %LDMA ( r =0.257; P =0.100)]. Conclusion: Results of this study indicate that the EI is moderately associated with muscle attenuation as assessed by CT, which means that higher EI at least partly reflects intramuscular lipid infiltration. Keywords: echogenicity, ultrasound imaging, CT value, low-density muscle area, muscle composition, muscle quality

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2147/cia.s173372

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

Metadata

Authors
Watanabe, Y., Ikenaga, M., Yoshimura, E., Yamada, Y., & Kimura, M.
Venue
Clinical Interventions in Aging
Published
2018-10
Volume
Volume 13
Pages
1871-1878
ISSN
  • 1176-9092 (ISSN-L)
  • 1178-1998
OpenAlex
W2893711496
Cited by
72
References
9
FWCI
3.56
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.