CoChat

Nasal highflow improves ventilation in patients with COPD

Open access
Bräunlich, Jens, Köhler, Marcus, Wirtz, Hubert · 2016 · International Journal of Chronic Obstructive Pulmonary Disease
Cited by 165

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Nasal highflow (NHF) provides a warmed and humidified air stream up to 60 L/min. Recent data demonstrated a positive effect in patients with acute hypoxemic respiratory failure, especially when caused by pneumonia. Preliminary data show a decrease in hypercapnia in patients with COPD. Therefore, NHF should be evaluated as a new ventilatory support device. This study was conducted to assess the impact of different flow rates on ventilatory parameters in patients with COPD. MATERIALS AND METHODS: This interventional clinical study was performed with patients suffering from severe COPD. The aim was to characterize flow-dependent changes in mean airway pressure, breathing volumes, breathing frequency, and decrease in partial pressure of CO2 (pCO2). Mean airway pressure was measured in the nasopharyngeal space (19 patients). To evaluate breathing volumes, we used a polysomnographic device (18 patients). All patients received 20 L/min, 30 L/min, 40 L/min, and 50 L/min and - to illustrate the effects - nasal continuous positive airway pressure and nasal bilevel positive airway pressure. Capillary blood gas analyses were performed in 54 patients with hypercapnic COPD before and two hours after the use of NHF. We compared the extent of decrease in pCO2 when using 20 L/min and 30 L/min. Additionally, comfort and dyspnea during the use of NHF were surveyed. RESULTS: NHF resulted in a minor flow dependent increase in mean airway pressure. Tidal volume increased, and breathing rate decreased. The calculated minute volume decreased under NHF breathing. In spite of this fact, hypercapnia decreased with increasing flow (20 L/min vs 30 L/min). Additionally, an improvement in dyspnea was observed. The rapid shallow breathing index shows a decrease when using NHF. CONCLUSION: NHF leads to a flow-dependent reduction in pCO2. This is most likely achieved by a washout of the respiratory tract and a functional reduction in dead space. In summary, NHF enhances effectiveness of breathing in patients with COPD, reduces pCO2, the work of breathing, and rapid shallow breathing index as an indicator of respiratory work load.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2147/copd.s104616

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Cited by

Metadata

Authors
Bräunlich, J., Köhler, M., & Wirtz, H.
Venue
International Journal of Chronic Obstructive Pulmonary Disease
Published
2016-05
Volume
11
Pages
1077
ISSN
  • 1176-9106 (ISSN-L)
  • 1178-2005
OpenAlex
W2405289598
Cited by
165
References
33
FWCI
14.57
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.