Biocompatibility of magnetic Fe3O4 nanoparticles and their cytotoxic effect on MCF-7 cells
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The objective of this study was to evaluate the synthesis and biocompatibility of Fe₃O₄ nanoparticles and investigate their therapeutic effects when combined with magnetic fluid hyperthermia on cultured MCF-7 cancer cells. METHODS: Magnetic Fe₃O₄ nanoparticles were prepared using a coprecipitation method. The appearance, structure, phase composition, functional groups, surface charge, magnetic susceptibility, and release in vitro were characterized by transmission electron microscopy, x-ray diffraction, scanning electron microscopy-energy dispersive x-ray spectroscopy, and a vibrating sample magnetometer. Blood toxicity, in vitro toxicity, and genotoxicity were investigated. Therapeutic effects were evaluated by MTT [3-(4, 5-dimethyl-2-thiazolyl)-2, 5-diphenyl-2H-tetrazolium bromide] and flow cytometry assays. RESULTS: Transmission electron microscopy revealed that the shapes of the Fe₃O₄ nanoparticles were approximately spherical, with diameters of about 26.1 ± 5.2 nm. Only the spinel phase was indicated in a comparison of the x-ray diffraction data with Joint Corporation of Powder Diffraction Standards (JCPDS) X-ray powder diffraction files. The O-to-Fe ratio of the Fe₃O₄was determined by scanning electron microscopy-energy dispersive x-ray spectroscopy elemental analysis, and approximated pure Fe₃O₄. The vibrating sample magnetometer hysteresis loop suggested that the Fe₃O₄nanoparticles were superparamagnetic at room temperature. MTT experiments showed that the toxicity of the material in mouse fibroblast (L-929) cell lines was between Grade 0 to Grade 1, and that the material lacked hemolysis activity. The acute toxicity (LD(50)) was 8.39 g/kg. Micronucleus testing showed no genotoxic effects. Pathomorphology and blood biochemistry testing demonstrated that the Fe₃O₄ nanoparticles had no effect on the main organs and blood biochemistry in a rabbit model. MTT and flow cytometry assays revealed that Fe₃O₄ nano magnetofluid thermotherapy inhibited MCF-7 cell proliferation, and its inhibitory effect was dose-dependent according to the Fe₃O₄ nano magnetofluid concentration. CONCLUSION: The Fe₃O₄ nanoparticles prepared in this study have good biocompatibility and are suitable for further application in tumor hyperthermia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of Magnetic Fluid Hyperthermia (MFH) on C3H mammary carcinoma in vivo
Jordan, A., Scholz, R., Wust, P., Fähling, H., Krause, J., Wlodarczyk, W., Sander, B., Vogl, T., & Felix, R. (1997) · International Journal of Hyperthermia · doi:10.3109/02656739709023559 · Cited by 325 · cited 1×
“Jordan first proposed magnetic fluid hyperthermia technology based on this principle.(2,3) The advent of magnetic fluid hyperthermia technology and the continuous innovation and development of related equipment and technologies has brought new vitality to traditional tumor thermotherapy.”
Jordan, A., Wust, P., Scholz, R., Tesche, B., Fähling, H., Mitrovics, T., Vogl, T., Cervós-navarro, J., & Felix, R. (1996) · International Journal of Hyperthermia · doi:10.3109/02656739609027678 · Cited by 259 · cited 1×
“Jordan first proposed magnetic fluid hyperthermia technology based on this principle.(2,3) The advent of magnetic fluid hyperthermia technology and the continuous innovation and development of related equipment and technologies has brought new vitality to traditional tumor thermotherapy.”
Can Standard Genotoxicity Tests be Applied to Nanoparticles?
Magdolenova, Z., Lorenzo, Y., Collins, A., & Dusinska, M. (2012) · Journal of Toxicology and Environmental Health, Part A · doi:10.1080/15287394.2012.690326 · Cited by 121 · cited 1×
“The micronucleus test is a quick method for assessing if biomaterials can cause chromosomal damage and interfere with mitosis.(18) This test found no significant difference in the rate of micronucleus formation in bone marrow between mice of the material and of the negative control group Table 3 results of acute toxic…”
Thorat, N. D., Shinde, K. P., Pawar, S. H., Barick, K. C., Betty, C. A., & Ningthoujam, R. S. (2012) · Dalton Transactions · doi:10.1039/c2dt11835a · Cited by 115 · cited 1×
“Biocompatibility is the most fundamental prerequisite for the clinical application of any biomaterial.(12) Governments and academic circles are attaching increasing importance to the safety of medical materials.”
Islam, T., & Josephson, L. (2009) · Cancer Biomarkers · doi:10.3233/cbm-2009-0615 · Cited by 96
Poly-l-lysine-coated magnetic nanoparticles as intracellular actuators for neural guidance.
Raffa, V., Riggio, C., Calatayud, Hoskins, Pinkernelle, Goya, Wang, L., Keilhoff, & Cuschieri, A. (2012) · International Journal of Nanomedicine · doi:10.2147/ijn.s28460 · Cited by 83 · cited 1×
“MTT is a basic method of evaluating the biocompatibility of biomaterials when studying cytotoxicity.(15) It is a simple,”
Tang, Q., Zhang, D.-S., Cong, X.-M., Wan, M.-L., & Jin, L.-Q. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.01.038 · Cited by 66
Self-citationXin, B., Si, S., & Xing, G. (2010) · Chemistry - An Asian Journal · doi:10.1002/asia.200900696 · Cited by 39
Hyperthermia and tumour necrosis factor-α induced apoptosis via mitochondrial damage
Yuen, W., Fung, K., Lee, C. Y., Choy, Y. M., Kong, S. K., Ko, S., & Kwok, T. T. (2000) · Life Sciences · doi:10.1016/s0024-3205(00)00656-1 · Cited by 29
Cited by
Recent progress of magnetic nanoparticles in biomedical applications: A review
Anik, M. I., Hossain, M. K., Hossain, I., Mahfuz, A. M. U. B., Rahman, M. T., & Ahmed, I. (2021) · Nano Select · doi:10.1002/nano.202000162 · Cited by 300
Abdullah, N. H., Shameli, K., Abdullah, E. C., & Abdullah, L. C. (2019) · Composites Part B: Engineering · doi:10.1016/j.compositesb.2018.12.075 · Cited by 214
Gul, K., Sohni, S., Waqar, M., Ahmad, F., Norulaini, N. A. N., & A. K., M. O. (2016) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2016.06.045 · Cited by 205
“GO might be due to the structural imperfections induced by sonication, heat treatment and smaller platelet sizes caused by sonication (Chen et al., 2012; Ruoff, Stoller, & Zhu, 2011; Teymourian, Salimi, & Khezrian, 2013).”
Liu, L., Chen, B., Liu, K., Gao, J., Ye, Y., Wang, Z., Qin, N., Wilson, D. A., Tu, Y., & Peng, F. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201910108 · Cited by 150
Metadata
- Authors
- Chen, D.-Z., Tang, Q., Li, X., Zhou, X., Zang, J., Xiang, J.-Y., Guo, C.-Q., & Xue
- Venue
- International Journal of Nanomedicine
- Publisher
- Informa UK Limited
- Published
- 2012-09
- Volume
- 7
- Pages
- 4973
- ISSN
- 1176-9114 (ISSN-L)
- 1178-2013
- OpenAlex
- W2064697206
- Cited by
- 161
- References
- 9
- FWCI
- 4.01
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biocompatibility of magnetic Fe3O4 nanoparticles and their cytotoxic effect on MCF-7 cells. https://app.cochat.ai/papers/10.2147/ijn.s35140
- The paper
- Chen, D.-Z., Tang, Q., Li, X., Zhou, X., Zang, J., Xiang, J.-Y., Guo, C.-Q., & Xue. (2012). Biocompatibility of magnetic Fe3O4 nanoparticles and their cytotoxic effect on MCF-7 cells. International Journal of Nanomedicine. https://doi.org/10.2147/ijn.s35140
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.