The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A review of spinal cord stimulation systems for chronic pain
Open accessAbstract
Spinal cord stimulation (SCS) applications and technologies are fast advancing. New SCS technologies are being used increasingly in the clinical environment, but often there is a lag period between the clinical application and the publishing of high-quality evidence on safety and efficacy. Recent developments will undoubtedly expand the applicability of SCS, allowing more effective and individualized treatment for patients, and may have the potential to salvage patients who have previously failed neuromodulation. Already, high-level evidence exists for the safety, efficacy, and cost-effectiveness (Level I-II) of traditional SCS therapies in the treatment of chronic refractory low back with predominant limb pain (regardless of surgical history). More than half of all patients with chronic painful conditions experience sustained and significant levels of pain reduction following SCS treatment. Although only limited evidence exists for burst stimulation, there is now Level I evidence for both dorsal root ganglion SCS and high-frequency SCS that demonstrates compelling results compared with traditional therapies. The body of evidence built on traditional SCS research may be redundant, with newer iterations of SCS therapies such as dorsal root ganglion SCS, high-frequency SCS, and burst SCS. A number of variables have been identified that can affect SCS efficacy: implanter experience, appropriate patient selection, etiologies of patient pain, existence of comorbidities, including psychiatric illness, smoking status, and delay to SCS implant following pain onset. Overall, scientific literature demonstrates SCS to be a safe, effective, and drug-free treatment option for many chronic pain etiologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Epidemiology of chronic musculoskeletal pain
McBeth, J., & Jones, K. (2007) · Best Practice & Research Clinical Rheumatology · doi:10.1016/j.berh.2007.03.003 · Cited by 602
Eldabe, S., Buchser, E., & Duarte, R. V. (2016) · Pain Medicine · doi:10.1093/pm/pnv025 · Cited by 403
Cited by
Management of Musculoskeletal Pain: An Update with Emphasis on Chronic Musculoskeletal Pain
El-Tallawy, S. N., Nalamasu, R., Salem, G. I., LeQuang, J. A. K., Pergolizzi, J. V., & Christo, P. J. (2021) · Pain and Therapy · doi:10.1007/s40122-021-00235-2 · Cited by 532
Emerging Modalities and Implantable Technologies for Neuromodulation
Won, S. M., Song, E., Reeder, J. T., & Rogers, J. A. (2020) · Cell · doi:10.1016/j.cell.2020.02.054 · Cited by 291
Complex regional pain syndrome: a narrative review for the practising clinician
Shim, H., Rose, J., Halle, S., & Shekane, P. (2019) · British Journal of Anaesthesia · doi:10.1016/j.bja.2019.03.030 · Cited by 265
Wireless power delivery techniques for miniature implantable bioelectronics
Singer, A., & Robinson, J. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100664 · Cited by 159
Wang, Y., Xie, K., Yue, H., Chen, X., Luo, X., Liao, Q., Liu, M., Wang, F., & Shi, P. (2020) · Nanoscale · doi:10.1039/c9nr07583f · Cited by 42
Metadata
- Authors
- Sinclair, C., Verrills, P., & Barnard, A.
- Venue
- Journal of Pain Research
- Publisher
- Informa UK Limited
- Published
- 2016-07
- Volume
- Volume 9
- Pages
- 481-492
- ISSN
- 1178-7090 (ISSN-L)
- OpenAlex
- W2470035536
- Cited by
- 245
- References
- 2
- FWCI
- 31.83
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.