CoChat

Test–retest reliability, validity, and minimum detectable change of visual analog, numerical rating, and verbal rating scales for measurement of osteoarthritic knee pain

Open access
Alghadir, Ahmad, Anwer, Shahnawaz, Iqbal, Amir, Iqbal, Zaheen · 2018 · Journal of Pain Research

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Several scales are commonly used for assessing pain intensity. Among them, the numerical rating scale (NRS), visual analog scale (VAS), and verbal rating scale (VRS) are often used in clinical practice. However, no study has performed psychometric analyses of their reliability and validity in the measurement of osteoarthritic (OA) pain. Therefore, the present study examined the test-retest reliability, validity, and minimum detectable change (MDC) of the VAS, NRS, and VRS for the measurement of OA knee pain. In addition, the correlations of VAS, NRS, and VRS with demographic variables were evaluated. METHODS: The study included 121 subjects (65 women, 56 men; aged 40-80 years) with OA of the knee. Test-retest reliability of the VAS, NRS, and VRS was assessed during two consecutive visits in a 24 h interval. The validity was tested using Pearson's correlation coefficients between the baseline scores of VAS, NRS, and VRS and the demographic variables (age, body mass index [BMI], sex, and OA grade). The standard error of measurement (SEM) and the MDC were calculated to assess statistically meaningful changes. RESULTS: The intraclass correlation coefficients of the VAS, NRS, and VRS were 0.97, 0.95, and 0.93, respectively. VAS, NRS, and VRS were significantly related to demographic variables (age, BMI, sex, and OA grade). The SEM of VAS, NRS, and VRS was 0.03, 0.48, and 0.21, respectively. The MDC of VAS, NRS, and VRS was 0.08, 1.33, and 0.58, respectively. CONCLUSION: All the three scales had excellent test-retest reliability. However, the VAS was the most reliable, with the smallest errors in the measurement of OA knee pain.

Overview

CoChat Summary

## TL;DR

This study evaluated the test–retest reliability, validity, and minimum detectable change of the VAS, NRS, and VRS for osteoarthritic knee pain in 121 patients. All three scales showed excellent reliability, with the VAS performing best in terms of reliability and measurement error.

## Key findings

  • In 121 subjects with knee OA, test–retest ICCs were 0.97 for VAS, 0.95 for NRS, and 0.93 for VRS.
  • Measurement error was smallest for VAS: SEM was 0.03, versus 0.48 for NRS and 0.21 for VRS; MDC was 0.08 for VAS, 1.33 for NRS, and 0.58 for VRS.
  • The three scales were significantly associated with demographic variables, and the paper reports good-to-excellent inter-scale correlations: VAS–NRS r = 0.941, VAS–VRS r = 0.878, and NRS–VRS r = 0.925.
  • Age, BMI, and OA grade were significantly correlated with all three scales, while sex was not correlated with any scale.

## Methods

  • Observational psychometric study of 121 patients with knee osteoarthritis (65 women, 56 men), aged 40–80 years; most had K–L grade 2–3 OA (75.3%).
  • Participants completed VAS, NRS, and VRS pain ratings in random order at baseline and again after 24 hours; two independent examiners were involved in both sessions.
  • Reliability was assessed with ICC2,1 and Bland–Altman plots; validity with Pearson correlations against age, BMI, sex, and OA grade; SEM and MDC were calculated from reliability results.

## Limitations

  • The paper states the results apply only to patients with pain due to OA of the knee, so use for other musculoskeletal pain conditions requires caution.
  • The participants had chronic pain (>6 months), so the authors say more research is needed for different stages of pain.
  • Education level was not assessed; the authors note it might affect pain perception and should be examined in future work.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.2147/jpr.s158847

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Bland–Altman plot: intraindividual differences (n = 121) between the visual analog scale (VAS) on test and retest, plotted against the average of the two scores. Note: The central line represents the mean difference, and the dashed lines display the 95% limit of agreement.
Figure 1 Bland–Altman plot: intraindividual differences (n = 121) between the visual analog scale (VAS) on test and retest, plotted against the average of the two scores. Note: The central line represents the mean difference, and the dashed lines display the 95% limit of agreement.CC BY-NC · PubMed Central
Figure 2 Bland–Altman plot: intraindividual differences (n = 121) between the numerical rating scale (NRS) on test and retest, plotted against the average of the two scores. Note: The central line represents the mean difference, and the dashed lines display the 95% limit of agreement.
Figure 2 Bland–Altman plot: intraindividual differences (n = 121) between the numerical rating scale (NRS) on test and retest, plotted against the average of the two scores. Note: The central line represents the mean difference, and the dashed lines display the 95% limit of agreement.CC BY-NC · PubMed Central

Verification

Claims the paper makes

0 Valid · 1 Not valid · 0 Not checked · 26 Own results and interpretations

17 more claims

Create a free account to see all 27 claims and every source verdict.

See all claims — free account
  • Borderline: one of the tests for a substantial claim is unclear. 1
  • The quote only partly states this claim. 3
  • Probably not a substantial claim. 1
  • It may state two separate claims as one. 1

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 38 references

Cited by

Metadata

Authors
Alghadir, A., Anwer, S., Iqbal, A., & Iqbal, Z.
Affiliations
King Saud University (SA)
Corresponding author
  • Alghadir, Ahmad
  • Anwer, Shahnawaz
  • Iqbal, Amir
  • Iqbal, Zaheen
Venue
Journal of Pain Research
Published
2018-04
Volume
Volume 11
Pages
851-856
ISSN
1178-7090 (ISSN-L)
OpenAlex
W2801509064
Cited by
783
References
38
Citations by year
2026: 122 · 2025: 165 · 2024: 123 · 2023: 123 · 2022: 94 · 2021: 79 · 2020: 59 · 2019: 16 · 2018: 1
FWCI
25.01
Type
journal article
Language
en
Open access
Locations
  • Journal of Pain Research (publishedVersion, cc-by-nc)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • Dove Medical Press (Taylor and Francis Group) (submittedVersion, cc-by-nc)
Funders
  • King Saud University
  • Deanship of Scientific Research, King Saud University
Topics
  • Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Musculoskeletal pain and rehabilitation
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Opioid Use
Keywords
knee osteoarthritis, pain intensity assessment, visual analogue scale, numerical rating scale, verbal rating scale, test-retest reliability, validity, minimal detectable change, standard error of measurement, psychometric properties

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.