The DOI matches its Crossref record.
Demonstration and evaluation of germicidal UV-LEDs for point-of-use water disinfection
Abstract
Ultraviolet (UV) irradiation is a common disinfection option for water treatment in the developed world. There are a few systems installed in developing countries for point-of-use treatment, but the low-pressure mercury lamps currently used as the UV irradiation source have a number of sustainability issues including a fragile envelope, a lifetime of approximately one year, and they contain mercury. UV light emitting diodes (LEDs) may offer solutions to many of the sustainability issues presented by current UV systems. LEDs are small, efficient, have long lifetimes, and do not contain mercury. Germicidal UV LEDs emitting at 265 nm were evaluated for inactivation of E. coli in water and compared to conventional low-pressure UV lamps. Both systems provided an equivalent level of treatment. A UV-LED prototype was developed and evaluated as a proof-of-concept of this technology for a point-of-use disinfection option, and the economics of UV-LEDs were evaluated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Graves, D. B. (2012) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/45/26/263001 · Cited by 1,518
Evaluating UV-C LED disinfection performance and investigating potential dual-wavelength synergy
Beck, S. E., Ryu, H., Boczek, L. A., Cashdollar, J. L., Jeanis, K. M., Rosenblum, J. S., Lawal, O. R., & Linden, K. G. (2017) · Water Research · doi:10.1016/j.watres.2016.11.024 · Cited by 339
Self-citationLED revolution: fundamentals and prospects for UV disinfection applications
Chen, J., Loeb, S., & Kim, J.-H. (2017) · Environmental Science: Water Research & Technology · doi:10.1039/c6ew00241b · Cited by 331
Li, G.-Q., Wang, W.-L., Huo, Z.-Y., Lu, Y., & Hu, H.-Y. (2017) · Water Research · doi:10.1016/j.watres.2017.09.030 · Cited by 305
Impact of 280 nm UV-C LEDs on the microbial safety and nutritional quality in tender coconut water
Maguluri, R. K., Dasalkar, A. H., Singam, S. S. R., & Yannam, S. K. (2023) · Food and Humanity · doi:10.1016/j.foohum.2023.08.003 · Cited by 8
Metadata
- Authors
- Chatterley, C., & Linden, K.
- Venue
- Journal of Water and Health
- Publisher
- IWA Publishing
- Published
- 2010-03-09
- Volume
- 8
- Issue
- 3
- Pages
- 479-486
- ISSN
- 1477-8920 (ISSN-L)
- 1996-7829
- OpenAlex
- W2106720111
- Cited by
- 206
- References
- 0
- FWCI
- 2.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Demonstration and evaluation of germicidal UV-LEDs for point-of-use water disinfection. https://app.cochat.ai/papers/10.2166/wh.2010.124
- The paper
- Chatterley, C., & Linden, K. (2010). Demonstration and evaluation of germicidal UV-LEDs for point-of-use water disinfection. Journal of Water and Health. https://doi.org/10.2166/wh.2010.124
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.