Evaluating an iron-coated sand for removing copper from water
The DOI matches its Crossref record.
Abstract
In drinking water treatment systems, the conventional process (coagulation, sedimentation and filtration units) cannot remove trace metals efficiently. Iron oxide is an excellent, regenerable adsorbent, and often controls free metals through adsorption. The utilization of heating process for coating iron oxide on sand surface allowed the media to be used in a packed column. The adsorbent media were investigated for removing copper ions from water using both batch and column experimental methods. A one-dimensional convective-dispersive transport model with a combination of second-order kinetic adsorption equation was adopted for predicting copper retention in a 80 cm depth filter bed. The concentration of copper ions in influent ranged from 0.64 to 3.2 mg/l. The experimental results indicated that the copper could be removed completely until the breakpoint. Once breakthrough occurred, the regeneration of the media could be achieved by soaking with acid solution (pH = 3.0). The simulation results of the transport-adsorption equation fit experimental data quite well. Consequently, the coated sand can be applied for the conventional rapid filtration process to remove copper ions from water.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
KATSOYIANNIS, I., & ZOUBOULIS, A. (2002) · Water Research · doi:10.1016/s0043-1354(02)00236-1 · Cited by 442
Comparative study of adsorption properties of Turkish fly ashes
Bayat, B. (2002) · Journal of Hazardous Materials · doi:10.1016/s0304-3894(02)00140-1 · Cited by 300
Gupta, V. K., Singh, P., & Rahman, N. (2004) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2004.02.046 · Cited by 217
Kinetic and isotherm studies of cadmium adsorption on manganese nodule residue
Agrawal, A., & Sahu, K. K. (2006) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2006.03.039 · Cited by 197
Arsenic Removal Using Iron Oxide Loaded Alginate Beads
Zouboulis, A. I., & Katsoyiannis, I. A. (2002) · Industrial & Engineering Chemistry Research · doi:10.1021/ie0203835 · Cited by 193
Removal of Se(IV) and Se(VI) from water by aluminum-oxide-coated sand
Kuan, W.-H., Lo, S.-L., Wang, M. K., & Lin, C.-F. (1998) · Water Research · doi:10.1016/s0043-1354(97)00228-5 · Cited by 159
Self-citationTripathy, S. S., & Raichur, A. M. (2008) · Chemical Engineering Journal · doi:10.1016/j.cej.2007.06.028 · Cited by 118
Tahir, S. S., & Rauf, N. (2004) · Journal of Environmental Management · doi:10.1016/j.jenvman.2004.06.009 · Cited by 106
Metadata
- Authors
- Lai, C. H., Lo, S. L., & Lin, C. F.
- Venue
- Water Science and Technology
- Publisher
- IWA Publishing
- Published
- 1994-11-01
- Volume
- 30
- Issue
- 9
- Pages
- 175-182
- ISSN
- 0273-1223 (ISSN-L)
- 1996-9732
- OpenAlex
- W2317566231
- Cited by
- 38
- References
- 0
- FWCI
- 2.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.