Benefits and drawbacks of thermal pre-hydrolysis for operational performance of wastewater treatment plants
The DOI matches its Crossref record.
Abstract
This paper presents benefits and potential drawbacks of thermal pre-hydrolysis of sewage sludge from an operator's prospective. The innovative continuous Thermo-Pressure-Hydrolysis Process (TDH) has been tested in full-scale at Zirl wastewater treatment plant (WWTP), Austria, and its influence on sludge digestion and dewatering has been evaluated. A mathematical plant-wide model with application of the IWA Activated Sludge Model No.1 (ASM1) and the Anaerobic Digestion Model No.1 (ADM1) has been used for a systematic comparison of both scenarios—operational plant performance with and without thermal pre-hydrolysis. The impacts of TDH pre-hydrolysis on biogas potential, dewatering performance and return load in terms of ammonia and inert organic compounds (Si) have been simulated by the calibrated model and are displayed by Sankey mass flow figures. Implementation of full scale TDH process provided higher anaerobic degradation efficiency with subsequent increased biogas production (+75–80%) from waste activated sludge (WAS). Both effects—enhanced degradation of organic matter and improved cake's solids content from 25.2 to 32.7% TSS—promise a reduction in sludge disposal costs of about 25%. However, increased ammonia release and generation of soluble inerts Si was observed when TDH process was introduced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Thermal hydrolysis for sewage treatment: A critical review
Barber, W. P. F. (2016) · Water Research · doi:10.1016/j.watres.2016.07.069 · Cited by 484
“8 determined from theory and based on expected dewaterability (Higgins et al., 2015; Phothilangka et al., 2008; Everett, 1972) and digestion performance (van Dijk and de Man, 2010; Stuckey and McCarty, 1984; Haug et al., 1978) and complements a previous study (Barber et al., 2012).”
BackgroundInfluentialWei, L., Zhu, F., Li, Q., Xue, C., Xia, X., Yu, H., Zhao, Q., Jiang, J., & Bai, S. (2020) · Environment International · doi:10.1016/j.envint.2020.106093 · Cited by 434
Li, B., Romero, A., Wadhawan, T., Tobin, M., Manning, E., Higgins, M., Al‐Omari, A., Murthy, S., Riffat, R., & De Clippeleir, H. (2020) · Water Environment Research · doi:10.1002/wer.1230 · Cited by 21
Thermal Hydrolysis of Sewage Sludge: A Case Study of a WWTP in Burgos, Spain
García-Cascallana, J., Barrios, X. G., & Martinez, E. J. (2021) · Applied Sciences · doi:10.3390/app11030964 · Cited by 20
“[57], who also indicated that this improvement”
Metadata
- Authors
- Phothilangka, P., Schoen, M. A., & Wett, B.
- Venue
- Water Science and Technology
- Publisher
- IWA Publishing
- Published
- 2008-10-01
- Volume
- 58
- Issue
- 8
- Pages
- 1547-1553
- ISSN
- 0273-1223 (ISSN-L)
- 1996-9732
- OpenAlex
- W2068530479
- Cited by
- 49
- References
- 0
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Benefits and drawbacks of thermal pre-hydrolysis for operational performance of wastewater treatment plants. https://app.cochat.ai/papers/10.2166/wst.2008.500
- The paper
- Phothilangka, P., Schoen, M. A., & Wett, B. (2008). Benefits and drawbacks of thermal pre-hydrolysis for operational performance of wastewater treatment plants. Water Science and Technology. https://doi.org/10.2166/wst.2008.500
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.