Real-time monitoring of membrane bioreactors with 2D-fluorescence data and statistically based models
The DOI matches its Crossref record.
Abstract
The application of membrane bioreactors (MBR) for wastewater treatment is growing worldwide due to their compactness and high effluent quality. However, membrane fouling, mostly associated to biological products, can reduce MBR performance. Therefore, it is important to monitor MBRs as close to real-time as possible to accelerate control actions for maximal biological and membrane performance. 2D-fluorescence spectroscopy is a promising on-line tool to simultaneously monitor wastewater treatment efficiency and the formation of potential biological fouling agents. In this study, 2D-fluorescence data obtained from the wastewater and the permeate of a MBR was successfully modelled using projection to latent structures (PLS) to monitor variations in the influent and effluent total chemical oxygen demand (COD). Analysis of the results also indicated that humic acids and proteins highly contributed to the measured COD in both streams. Nevertheless, this approach was not valid for other performance parameters of the MBR system (such as influent and effluent ammonia and phosphorus), which is usually characterised through a high number of analytical and operating parameters. Principal component analysis (PCA) was thus used to find possible correlations between these parameters, in an attempt to reduce the analytical effort required for full MBR characterisation and to reduce the time frame necessary to obtain monitoring results. The 3 first principal components, capturing 57% of the variance, indicated and confirmed expected relationships between the assessed parameters. However, this approach alone could not provide robust enough correlations to enable the elimination of parameters for process description (PCA loadings ≤ 0.5). Nevertheless, it is possible that the information captured by 2D-fluorescence spectroscopy could replace some of the analytical and operating parameters, since this technique was able to successfully describe influent and effluent total COD. It is thus proposed that combined modelling of 2D-fluorescence data and selected performance/operating parameters should be further explored for efficient MBR monitoring aiming at rapid process control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluorescence spectroscopy for wastewater monitoring: A review
Carstea, E. M., Bridgeman, J., Baker, A., & Reynolds, D. M. (2016) · Water Research · doi:10.1016/j.watres.2016.03.021 · Cited by 666
Galinha, C. F., Carvalho, G., Portugal, C. A. M., Guglielmi, G., Reis, M. A. M., & Crespo, J. G. (2012) · Water Research · doi:10.1016/j.watres.2012.04.010 · Cited by 48
Self-citationMishra, A., Aghaee, M., Tamer, I. M., & Budman, H. (2025) · Spectroscopy Journal · doi:10.3390/spectroscj3020012 · Cited by 19
“[86] observed that fluorescence signals can be highly sensitive to changes in bioreactor conditions such as pH, temperature, and ionic strength.”
Development of a hybrid model strategy for monitoring membrane bioreactors
Galinha, C. F., Guglielmi, G., Carvalho, G., Portugal, C. A. M., Crespo, J. G., & Reis, M. A. M. (2013) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2012.06.026 · Cited by 12
Self-citation
Metadata
- Authors
- Galinha, C. F., Carvalho, G., Portugal, C. A. M., Guglielmi, G., Oliveira, R., Crespo, J. G., & Reis, M. A. M.
- Venue
- Water Science and Technology
- Publisher
- IWA Publishing
- Published
- 2011-04-01
- Volume
- 63
- Issue
- 7
- Pages
- 1381-1388
- ISSN
- 0273-1223 (ISSN-L)
- 1996-9732
- OpenAlex
- W1989654719
- Cited by
- 34
- References
- 0
- FWCI
- 5.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.