Anaerobic threshold determination by blood lactate and myoelectric signals.
Open accessThe DOI matches its Crossref record.
Abstract
This study examined the potential use of myoelectric signal analysis for determination of anaerobic threshold (AT). Ten college students performed incremental exercise on a bicycle ergometer during which blood samples from either the brachial or radial artery were drawn and corresponding intergrated electromyogram (IEMG) and power spectra also were recorded. Blood AT was determined by observing the changes in arterial blood lactate, Po2 Pco2, HCO3-, and pH. EMG AT was determined by the non-linear increase in IEMG and abrupt increase in frequency band width at 70% of the peak frequency (FRQ70%) which could represent the most active frequency band. The results indicated that a significant increase in FRQ70% occurred immediately after the occurrence of blood AT (p less than 0.05). However, no significant increase could be found in peak frequency. Regression analyses revealed that EMG AT Vo2 correlated significantly with blood AT Vo2 (r = 0.921, p less than 0.001) and with gas exchange AT Vo2 (r = 0.921, p less than 0.001). It was concluded that analysis of myoelectric signals, which reflect motor unit recruitment and discharge frequency, could provide a non-invasive estimate of AT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ekkekakis, P., Hall, E. E., & Petruzzello, S. J. (2004) · Preventive Medicine · doi:10.1016/j.ypmed.2003.09.038 · Cited by 228
“The transition from aerobic to anaerobic metabolism is associated with exponential changes in several perceptible peripheral physiological functions, including ventilation [44,93] and muscle activation [64,77].”
Background1998 ISEK Congress Keynote Lecture
Moritani, T., & Yoshitake, Y. (1998) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(98)00018-2 · Cited by 50
Self-citationCaen, K., Bourgois, J. G., Stassijns, E., & Boone, J. (2022) · European Journal of Applied Physiology · doi:10.1007/s00421-022-04942-2 · Cited by 41
“A second local threshold can be detected using surface electromyography (EMG) and exhibits a nonlinear increase in the integrated EMG signal (iEMGBP) (Nagata et al. 1981).”
BackgroundVentura, T. P., Borszcz, F. K., Aguiar, R. A. D., de Lucas, R. D., & Turnes, T. (2026) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2025-0240 · Cited by 3
Metadata
- Authors
- NAGATA, A., MURO, M., MORITANI, T., & YOSHIDA, T.
- Venue
- The Japanese Journal of Physiology
- Publisher
- Physiological Society of Japan
- Published
- 1981
- Volume
- 31
- Issue
- 4
- Pages
- 585-597
- ISSN
- 0021-521X (ISSN-L)
- 1881-1396
- OpenAlex
- W1510346370
- Cited by
- 77
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.