A longitudinal study on the interchangeable use of whole-body and local exercise thresholds in cycling
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Purpose This study longitudinally examined the interchangeable use of critical power (CP), the maximal lactate steady state (MLSS) and the respiratory compensation point (RCP) (i.e., whole-body thresholds), and breakpoints in muscle deoxygenation (m[HHb]BP) and muscle activity (iEMG BP) (i.e., local thresholds). Methods Twenty-one participants were tested on two timepoints (T1 and T2) with a 4-week period (study 1: 10 women, age = 27 ± 3 years, [Formula: see text] = 43.2 ± 7.3 mL min-1 kg-1) or a 12-week period (study 2: 11 men, age = 25 ± 4 years, [Formula: see text] = 47.7 ± 5.9 mL min-1 kg-1) in between. The test battery included one ramp incremental test (to determine RCP, m[HHb]BP and iEMG BP) and a series of (sub)maximal constant load tests (to determine CP and MLSS). All thresholds were expressed as oxygen uptake ([Formula: see text]) and equivalent power output (PO) for comparison. Results None of the thresholds were significantly different in study 1 ([Formula: see text]: P = 0.143, PO: P = 0.281), but differences between whole-body and local thresholds were observed in study 2 ([Formula: see text]: P < 0.001, PO: P = 0.024). Whole-body thresholds showed better 4-week test-retest reliability (TEM = 88-125 mL min-1 or 6-10 W, ICC = 0.94-0.98) compared to local thresholds (TEM = 189-195 mL min-1 or 15-18 W, ICC = 0.58-0.89). All five thresholds were strongly associated at T1 and T2 (r = 0.75-0.99), but their changes from T1 to T2 were mostly uncorrelated (r = - 0.41-0.83). Conclusion Whole-body thresholds (CP/MLSS/RCP) showed a close and consistent coherence taking into account a 3-6%-bandwidth of typical variation. In contrast, local thresholds (m[HHb]BP/iEMG BP) were characterized by higher variability and did not consistently coincide with the whole-body thresholds. In addition, we found that most thresholds evolved independently of each other over time. Together, these results do not justify the interchangeable use of whole-body and local exercise thresholds in practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Gas exchange is one of the most commonly used methods for assessing the evolution of gas exchange measurements (dot(V), VO2, carbon dioxide volume (VCO2) and minute ventilation (VE)) that allow detection of the respiratory compensation point (also referred to as ventilatory threshold (VT))8.”
From Reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis (2023) · cites this paper as [8]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A guideline of selecting and reporting intraclass correlation coefficients for reliability research
Koo, T. K., & Li, M. Y. (2016) · Journal of Chiropractic Medicine · doi:10.1016/j.jcm.2016.02.012 · Cited by 31,709 · cited 1×
“%) using a single-measurement, absolute-agreement, two-way mixedeffects model (Koo and Li 2016).”
MethodDevelopment of recommendations for SEMG sensors and sensor placement procedures
Hermens, H. J., Freriks, B., Disselhorst-Klug, C., & Rau, G. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00027-4 · Cited by 7,213
QUANTIFYING TEST-RETEST RELIABILITY USING THE INTRACLASS CORRELATION COEFFICIENT AND THE SEM
WEIR, J. P. (2005) · Journal of Strength and Conditioning Research · doi:10.1519/00124278-200502000-00038 · Cited by 4,842 · cited 1×
“The minimum difference (MD) to be considered a real change in each threshold on the 1 3 95% confidence level was calculated by multiplying TEM with 1.96 × √ 2 (Weir 2005).”
MethodInfluentialMeasures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635 · cited 2×
“%) after log-transformation of the variables (Hopkins 2000).”
MethodA new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103 · cited 3×
“RCP was determined by identifying the simultaneous occurrence of the first increase in V̇E/V̇CO2 , the second increase in V̇E and the deflection point in PETCO2 (Beaver et al. 1986; Binder et al. 2008).”
MethodJustification of the 4-mmol/l lactate threshold
Heck, H., Mader, A., Hess, G., Mücke, S., Müller, R., & Hollmann, W. (1985) · International Journal of Sports Medicine · doi:10.1055/s-2008-1025824 · Cited by 888 · cited 1×
“MLSS was defined as the highest PO that could be sustained for 30 min with a steady-state La− response, defined as an increase ≤ 1 mM between the 10th and 30th min (Heck et al. 1985).”
BackgroundLactate Threshold Concepts: How Valid are They?
Faude, O., Kindermann, W., & Meyer, T. (2009) · Sports Medicine · doi:10.2165/00007256-200939060-00003 · Cited by 882
Metabolic and respiratory profile of the upper limit for prolonged exercise in man
POOLE, D. C., WARD, S. A., GARDNER, G. W., & WHIPP, B. J. (1988) · Ergonomics · doi:10.1080/00140138808966766 · Cited by 779
Critical Power: An Important Fatigue Threshold in Exercise Physiology
POOLE, D. C., BURNLEY, M., VANHATALO, A., ROSSITER, H. B., & JONES, A. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000939 · Cited by 535
Binder, R. K., Wonisch, M., Corra, U., Cohen-Solal, A., Vanhees, L., Saner, H., & Schmid, J.-P. (2008) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e328304fed4 · Cited by 487 · cited 3×
“RCP was determined by identifying the simultaneous occurrence of the first increase in V̇E/V̇CO2 , the second increase in V̇E and the deflection point in PETCO2 (Beaver et al. 1986; Binder et al. 2008).”
Method
Cited by
Muscle Oximetry in Sports Science: An Updated Systematic Review
Perrey, S., Quaresima, V., & Ferrari, M. (2024) · Sports Medicine · doi:10.1007/s40279-023-01987-x · Cited by 100
Sendra-Pérez, C., Sanchez-Jimenez, J. L., Marzano-Felisatti, J. M., Encarnación-Martínez, A., Salvador-Palmer, R., & Priego-Quesada, J. I. (2023) · Scientific Reports · doi:10.1038/s41598-023-39651-z · Cited by 52
Muscle oxygen saturation rates coincide with lactate-based exercise thresholds
Batterson, P. M., Kirby, B. S., Hasselmann, G., & Feldmann, A. (2023) · European Journal of Applied Physiology · doi:10.1007/s00421-023-05238-9 · Cited by 45
The Respiratory Compensation Point: Mechanisms and Relation to the Maximal Metabolic Steady State
Keir, D. A., Pogliaghi, S., Inglis, E. C., Murias, J. M., & Iannetta, D. (2024) · Sports Medicine · doi:10.1007/s40279-024-02084-3 · Cited by 43
“Although CP is a helpful tool to identify the heavy-severe-intensity boundary, it too is an estimate of the MMSS that is subject to error in a range that is similar to RCP (~ 3–8%; [106, 107] or as much as ~ 100 mL min −1 or ~ 10 W).”
Critical Power and Maximal Lactate Steady State in Cycling: “Watts” the Difference?
Caen, K., Poole, D. C., Vanhatalo, A., & JONES, A. M. (2024) · Sports Medicine · doi:10.1007/s40279-024-02075-4 · Cited by 35
Self-citation
Metadata
- Authors
- Caen, K., Bourgois, J. G., Stassijns, E., & Boone, J.
- Affiliations
- Ghent University Hospital (BE)
- Ghent University (BE)
- Corresponding author
- Boone, Jan
- Venue
- European Journal of Applied Physiology
- Published
- 2022-04-18
- Volume
- 122
- Issue
- 7
- Pages
- 1657-1670
- ISSN
- 0020-9376 (ISSN-L)
- 1439-6319
- 1439-6327
- PMC
- PMC9014408
- OpenAlex
- W4224084566
- Cited by
- 41
- References
- 45
- Citations by year
- 2026: 8 · 2025: 12 · 2024: 11 · 2023: 7 · 2022: 3
- FWCI
- 8.62
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- European Journal of Applied Physiology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Ghent University Academic Bibliography (Ghent University) (submittedVersion)
- Funders
- Universiteit Gent
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Nursing › Nutrition and Dietetics › Muscle metabolism and nutrition
- Keywords
- critical power, maximal lactate steady state, respiratory compensation point, exercise threshold, cycling, test-retest reliability, incremental test, constant load test, oxygen consumption, output power, women and men differences
- MeSH terms
- Adult, Bicycling, Exercise Test, Female, Humans, Longitudinal Studies, Male, Oxygen Consumption, Reproducibility of Results, Lactic Acid, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A longitudinal study on the interchangeable use of whole-body and local exercise thresholds in cycling. https://app.cochat.ai/papers/10.1007/s00421-022-04942-2
- The paper
- Caen, K., Bourgois, J. G., Stassijns, E., & Boone, J. (2022). A longitudinal study on the interchangeable use of whole-body and local exercise thresholds in cycling. European Journal of Applied Physiology. https://doi.org/10.1007/s00421-022-04942-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.