Regional Difference of Muscle Oxygen Saturation and Blood Volume during Exercise Determined by Near Infrared Imaging Device.

Open access
Miura, Hajime, McCully, Kevin, Hong, Long, Nioka, Shoko, Chance, Britton · 2001 · The Japanese Journal of Physiology
Cited by 54

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

UNLABELLED: Using a near infrared (NIR) imaging device, we tested the hypothesis that regional differences in oxygen status could be detected in the gastrocnemius muscle during exercise and recovery. Six healthy subjects performed the standing plantar flexion exercises for 2 min; the frequency was one contraction per second. The NIR imaging device was placed over the medial head of the right gastrocnemius muscle and the signals from two optical sensors situated on the middle proximal and middle distal portions were used. The NIR-O(2) saturation (difference between deoxygenated and oxygenated Hb signals) and NIR-blood volume (sum of the oxygenated and deoxygenated Hb signals) were calculated in optical density units. Plantar flexion resulted in more deoxygenation during exercise and more reoxygenation during recovery in the distal portion compared with the proximal portion. The changes in NIR-O(2) between rest and a 2 min exercise, and between a 2 min exercise and a 3 min recovery were 0.11 and -0.23, respectively, in the distal portion, which were significantly larger than proximal values (0.05 and -0.10, p < 0.05). Plantar flexion resulted in lower NIR-blood volumes during exercise and greater recovery of blood after exercise in the distal portion compared with the proximal portion. The changes in NIR blood volume between rest and a 2 min exercise and between a 2 min exercise and a 3 min recovery were -0.19 and 0.31, respectively, in the distal portion, significantly larger than proximal values (-0.07 and 0.12, p < 0.05 for all comparisons). These findings indicate that the distal portion of the medial gastrocnemius had larger changes in NIR-O(2) saturation and NIR-blood volume than the proximal portion had. This is consistent with the distal portion having a greater impairment of blood flow possibly because of the higher intramuscular pressure during exercise. IN CONCLUSION: (1) regional differences in oxygen status in the gastrocnemius muscle were detected with exercise, with the distal portion having greater NIR-O(2) saturation and NIR-blood volume changes, and (2) the NIR imaging device might be a useful method to detect the regional differences of oxygen status in the muscle.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2170/jjphysiol.51.599

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 54

Metadata

Authors
Miura, H., McCully, K., Hong, L., Nioka, S., & Chance, B.
Venue
The Japanese Journal of Physiology
Published
2001
Volume
51
Issue
5
Pages
599-606
ISSN
0021-521X (ISSN-L)
OpenAlex
W2050747960
Cited by
54
References
5
FWCI
6.17
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.