Life cycle assessment of a biomass gasification combined-cycle power system
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The potential environmental benefits from biomass power are numerous. However, biomass power may also have some negative effects on the environment. Although the environmental benefits and drawbacks of biomass power have been debated for some time, the total significance has not been assessed. This study serves to answer some of the questions most often raised in regard to biomass power: What are the net CO{sub 2} emissions? What is the energy balance of the integrated system? Which substances are emitted at the highest rates? What parts of the system are responsible for these emissions? To provide answers to these questions, a life cycle assessment (LCA) of a hypothetical biomass power plant located in the Midwest United States was performed. LCA is an analytical tool for quantifying the emissions, resource consumption, and energy use, collectively known as environmental stressors, that are associated with converting a raw material to a final product. Performed in conjunction with a technoeconomic feasibility study, the total economic and environmental benefits and drawbacks of a process can be quantified. This study complements a technoeconomic analysis of the same process, reported in Craig and Mann (1996) and updated here. The process studied is based on the concept of power Generation in a biomass integrated gasification combined cycle (BIGCC) plant. Broadly speaking, the overall system consists of biomass production, its transportation to the power plant, electricity generation, and any upstream processes required for system operation. The biomass is assumed to be supplied to the plant as wood chips from a biomass plantation, which would produce energy crops in a manner similar to the way food and fiber crops are produced today. Transportation of the biomass and other materials is by both rail and truck. The IGCC plant is sized at 113 MW, and integrates an indirectly-heated gasifier with an industrial gas turbine and steam cycle. 63 refs., 34 figs., 32 tabs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Soil carbon sequestration beneath hybrid poplar plantations in the north central United States
Hansen, E. A. (1993) · Biomass and Bioenergy · doi:10.1016/0961-9534(93)90038-6 · Cited by 167
Cited by
Turconi, R., Boldrin, A., & Astrup, T. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.08.013 · Cited by 757
Scheuer, C., Keoleian, G. A., & Reppe, P. (2003) · Energy and Buildings · doi:10.1016/s0378-7788(03)00066-5 · Cited by 728
Life Cycle Assessment of Hydrogen Production via Natural Gas Steam Reforming
Spath, P. L., & Mann, M. K. (2000) · doi:10.2172/764485 · Cited by 579
Self-citationEnergy crops: current status and future prospects
SIMS, R. E. H., HASTINGS, A., SCHLAMADINGER, B., TAYLOR, G., & SMITH, P. (2006) · Global Change Biology · doi:10.1111/j.1365-2486.2006.01163.x · Cited by 489
Chum, H. L., & Overend, R. P. (2001) · Fuel Processing Technology · doi:10.1016/s0378-3820(01)00146-1 · Cited by 443
Metadata
- Authors
- Mann, M. K., & Spath, P. L.
- Published
- 1997-12-01
- OpenAlex
- W4243557598
- Cited by
- 82
- References
- 1
- Type
- report
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Life cycle assessment of a biomass gasification combined-cycle power system. https://app.cochat.ai/papers/10.2172/10106791
- The paper
- Mann, M. K., & Spath, P. L. (1997). Life cycle assessment of a biomass gasification combined-cycle power system. https://doi.org/10.2172/10106791
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.