The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Overgeneration from Solar Energy in California. A Field Guide to the Duck Chart
Open accessAbstract
In 2013, the California Independent System Operator published the 'duck chart,' which shows a significant drop in mid-day net load on a spring day as solar photovoltaics (PV) are added to the system. The chart raises concerns that the conventional power system will be unable to accommodate the ramp rate and range needed to fully utilize solar energy, particularly on days characterized by the duck shape. This could result in 'overgeneration' and curtailed renewable energy, increasing its costs and reducing its environmental benefits. This paper explores the duck chart in detail, examining how much PV might need to be curtailed if additional grid flexibility measures are not taken, and how curtailment rates can be decreased by changing grid operational practices. It finds that under "business-as-usual"" types of assumptions and corresponding levels of grid flexibility in California, solar penetrations as low as 20% of annual energy could lead to marginal curtailment rates that exceed 30%. However, by allowing (or requiring) distributed PV and storage (including new installations that are part of the California storage mandate) to provide grid services, system flexibility could be greatly enhanced. Doing so could significantly reduce curtailment and allow much greater penetration of variable generation resources. Overall, the work described in this paper points to the need to fully integrate distributed resources into grid system planning and operations to allow maximum use of the solar resource.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Western Wind and Solar Integration Study
Energy, G., & National Renewable Energy Laboratory (NREL), G. (2010) · doi:10.2172/981991 · Cited by 465
National Renewable Energy Laboratory
(2010) · Choice Reviews Online · doi:10.5860/choice.47-5675 · Cited by 350
Wind and Solar Energy Curtailment: Experience and Practices in the United States
Bird, L., Cochran, J., & Wang, X. (2014) · doi:10.2172/1126842 · Cited by 326
Western Wind and Solar Integration Study Phase 2
Lew, D. J., USDOE Office of Energy Efficiency and Renewable Energy (EERE), Brinkman, G., Ibanez, E., Florita, A. R., Heaney, M. D., Hodge, B., Hummon, M., Stark, G., King, J., et al. (2013) · doi:10.2172/1095399 · Cited by 293
Self-citationA tutorial of wind turbine control for supporting grid frequency through active power control
Aho, J., Buckspan, A., Laks, J., Fleming, P., Jeong, Y., Dunne, F., Churchfield, M., Pao, L., & Johnson, K. (2012) · 2012 American Control Conference (ACC) · doi:10.1109/acc.2012.6315180 · Cited by 274
Investigating the Impacts of Wind Generation Participation in Interconnection Frequency Response
Gevorgian, V., Zhang, Y., & Ela, E. (2015) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2014.2343836 · Cited by 239
Enabling Greater Penetration of Solar Power via the Use of CSP with Thermal Energy Storage
Denholm, P. L., & Mehos, M. (2011) · doi:10.2172/1030440 · Cited by 183
Self-citationMills, A., & Wiser, R. (2012) · doi:10.2172/1183176 · Cited by 173
Western Wind and Solar Integration Study Phase 3 – Frequency Response and Transient Stability
National Renewable Energy Lab. (NREL), G., Miller, N., Wind and Water Technologies Office (EE-4W) USDOE Office of Energy Efficiency and Renewable Energy (EERE), GE Energy Management, S., USDOE Office of Energy Efficiency and Renewable Energy (EERE), Shao, M., Pajic, S., & D'Aquila, R. (2014) · doi:10.2172/1167065 · Cited by 126
Mills, A., & Wiser, R. H. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.03.014 · Cited by 114
Denholm, P. L., USDOE Office of Energy Efficiency and Renewable Energy (EERE), Wan, Y. H., Hummon, M., & Mehos, M. (2013) · doi:10.2172/1072790 · Cited by 103
Self-citationGrid Integration and the Carrying Capacity of the U.S. Grid to Incorporate Variable Renewable Energy
Cochran, J., USDOE Office of Energy Efficiency and Renewable Energy (EERE), Denholm, P. L., Speer, B., & Miller, M. (2015) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/1215010 · Cited by 81
Self-citationDenholm, P. L., Margolis, R., Palmintier, B. S., Barrows, C., Ibáñez, E., Bird, L. A., & Zuboy, J. (2014) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/1159357 · Cited by 62
Self-citation
Cited by
Microgrids: A review of technologies, key drivers, and outstanding issues
Hirsch, A., Parag, Y., & Guerrero, J. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.03.040 · Cited by 1,493
Redox‐Flow Batteries: From Metals to Organic Redox‐Active Materials
Winsberg, J., Hagemann, T., Janoschka, T., Hager, M. D., & Schubert, U. S. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201604925 · Cited by 1,010
Hesse, H., Schimpe, M., Kucevic, D., & Jossen, A. (2017) · Energies · doi:10.3390/en10122107 · Cited by 770
Proton-conducting oxides for energy conversion and storage
Duan, C., Huang, J., Sullivan, N., & O'Hayre, R. (2020) · Applied Physics Reviews · doi:10.1063/1.5135319 · Cited by 530
Storage Requirements and Costs of Shaping Renewable Energy Toward Grid Decarbonization
Ziegler, M. S., Mueller, J. M., Pereira, G. D., Song, J., Ferrara, M., Chiang, Y.-M., & Trancik, J. E. (2019) · Joule · doi:10.1016/j.joule.2019.06.012 · Cited by 479
Metadata
- Authors
- Denholm, P., O'Connell, M., Brinkman, G., & Jorgenson, J.
- Published
- 2015-11-01
- OpenAlex
- W2423111827
- Cited by
- 559
- References
- 13
- Type
- report
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.