Project Final Report

Open access
Newell, Jonathan C. · 2005
Cited by 146

The DOI matches its Crossref record.

Abstract

Our first goal was to produce laboratory-scale test beds with a four-probe electrical impedance instrument having 32 current sources. The first test bed, filled with saline, resembles a larger lab-sized test bed at Lawrence Livermore National Lab. We studied arrays of four rods, each with 8 electrodes in this saline-filled tank. We then placed these rods in a test bed of Ottawa sand, and studied the conductivity of a saturated and unsaturated saline/sand bed. This test bed resembles the field test site in the ground at LLNL. The LLNL lab and the field site have only a single current source. Using our existing 32-source instrument, we studied an array of four 8-electrode probes in both the saline and sand tanks. The results were include in our report to you last year, and are summarized below. Figure 1 is a diagram of the four electrode rods, as seen from above, showing seven positions at which a small conductive target was placed, at the level of the middle of the rods. Figure 2 shows the sensitivity of the system to the target presence, as measured by norm distinguishability, at each of these seven positions. The distinguishability was substantially higher when the optimal, 32-source currents were used, compared to that available from only one current source [1], at all distances from the electrode array. Highest distinguishability was seen closest to the array, as expected, and the lowest distinguishability was seen at point 3, at the side of the array half way between two rods. Distinguishability was slightly higher than this at point 5 at the center of the four arrays. With these results in the saline tank in hand, we embedded the electrode rods in a 66 cm. diameter steel tank with an electrically insulated interior surface, filled to a depth of 48 cm. with Ottawa F-35 Grade sand. Experiments were conducted to verify the ability of this system to detect changes in the fluid level as saline was used to saturate the sand, and then drain out the bottom of the tank. Using simple current patterns to assess electrical resistance at the eight levels of electrodes, we found that after 5 days of draining, there was a gradient in local resistance of from 50-200 ohms at the bottom of the tank to 3000-4000 ohms at the top of the electrode array. When sufficient saline was added to saturate the field, local resistance fell to 70-110 ohms at all levels. When this saturating saline was allowed to drain, resistance began to rise at the topmost electrode level within 2 minutes, and continued to rise for at least the next two days, reaching 2000-4000 ohms at the top layers. We then studied the ability of the system to detect a plume of saline in an otherwise drained tank. Saline was introduced at the midpoint between rods 1 and 2 at rate of 200 ml/min, and allowed to drain freely at the bottom of the tank. No change was seen at 2 min, but by 6 min there was a substantial fall in the resistance at the top of rods 1 and 2, but not in 3 or 4. After 30 minutes of plume flow, the resistance at rods 1 and 2 had fallen below 1000 ohms at all levels, but that of rods 3 and 4 was 1500-4000 ohms at the top levels, remaining below 500 ohms at the lowest electrode levels. These results were qualitatively just as we would have expected. In making a detailed analysis of these data, however, we discovered a puzzling and unexpected finding: there was hysteresis of the complex impedance. That is, the sand bed behaved differently when being filled with saline than when being drained. This phenomenon had been observed previously in a study of the hydration of sandstone published by Knight et al. in 1991. The hypothesized explanation is based on surface tension phenomena at the scale of pores in the medium. We have also studied both the real and reactive components of electrical impedance in this system, and the found them to behave differently. This finding allows further data to be extracted from impedance measurements, compared to resistance measurements alone. Details of all these findings are reported in the enclosed manuscript. We have been working closely with Dr. Carrigan at LLNL to interpret them both in terms of their agreement with reasonable hypotheses about soil and water behavior, and in terms of their support for the use of multiple current sources in field-scale experiments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2172/836684

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Newell, J. C.
Published
2005-02-04
OpenAlex
W2345719300
Cited by
146
References
0
Type
report
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.