Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 257

The DOI matches its Crossref record.

Boronic Acid-Based Sensors

Wang, Wei, Gao, Xingming, Wang, Binghe·2002·Current Organic Chemistry

Abstract

There has been a great deal of interest in recent years in using boronic acid as the recognition motif for the development of sensors. Because boronic acids can form tight and reversible complexes with diol compounds such as carbohydrates, the majority of the efforts, led by the Shinkai group, have been on the development of sensors for carbohydrates. Boronic acids are also known to selectively recognize fluoride among halides and other anions. Therefore, there have also been efforts in using boronic acid compounds for the development fluoride sensors. This paper reviews the progress in this field during the last five years. Keywords: Boronic, Acid-Based Sensors

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2174/1385272023373446

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 257

Metadata

Authors
Wang, W., Gao, X., & Wang, B.
Venue
Current Organic Chemistry
Published
2002-12-01
Volume
6
Issue
14
Pages
1285-1317
ISSN
1385-2728 (ISSN-L)
OpenAlex
W2034530919
Cited by
257
References
0
FWCI
9.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Boronic Acid-Based Sensors. https://app.cochat.ai/papers/10.2174/1385272023373446
The paper
Wang, W., Gao, X., & Wang, B. (2002). Boronic Acid-Based Sensors. Current Organic Chemistry. https://doi.org/10.2174/1385272023373446

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.