Time-Resolved Confocal Fluorescence Imaging and Spectrocopy System with Single Molecule Sensitivity and Sub-Micrometer Resolution
The DOI matches its Crossref record.
Abstract
We present novel technical features and results from a two channel confocal fluorescence lifetime microscope, which allows to efficiently investigate fluorescence dynamics down to the single molecule level. The MicroTime 200 time-resolved fluorescence microscope offers a multicolor excitation where different picosecond diode lasers are used. For imaging and positioning purposes we utilize a compact Piezo scanner which allows, due to a novel scanning algorithm and synchronisation technique, a superior movement and positioning accuracy. The data acquisition is completely based on time-correlated single photon counting, where every photon is detected and stored individually with its specific timing information (Time-Tagged Time-Resolved mode). This multiparameter data acquisition scheme offers the opportunity to analyse the parameter dependencies in a multitude of different ways. Standard intensity analysis can be used to reconstruct 2D-images or the temporal evolution (time trace) of the fluorescence of a single spot. The information from the two distinct detector channels additionally allows to investigate the polarisation of the emitted light or its spectral composition, for example for analysis of Fluorescence Resonance Energy Transfer (FRET). The timing information down to a picosecond scale offers the possibility not only to reconstruct fluorescence decay constants of each pixel for the purpose of Fluorescence Lifetime Imaging (FLIM) but also to analyze the fluorescence fluctuation correlation function of any single spot of interest. The flexible multichannel detector scheme enables in this case also a cross-correlation between spectrally separated parts of the emission light, or even identical parts of the fluorescence to eliminate detector artifacts. The photon arrival coincidence analysis can also be expanded in the sub-ns range to study fluorescence antibunching in the fluorescence emission of single molecules. The ability of combining these different pieces of temporal information allows the construction of extremely powerful analysis methods and assays. We demonstrate a variety of these capabilities with results obtained from fluorescently labeled latex beads, biological samples, and single molecules excited in the blue or red wavelength region.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Invited Review Article: Single-photon sources and detectors
Eisaman, M. D., Fan, J., Migdall, A., & Polyakov, S. V. (2011) · Review of Scientific Instruments · doi:10.1063/1.3610677 · Cited by 1,358
Protein folding studied by single-molecule FRET
Schuler, B., & Eaton, W. A. (2008) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2007.12.003 · Cited by 697
A fluorescent membrane tension probe
Colom, A., Derivery, E., Soleimanpour, S., Tomba, C., Molin, M. D., Sakai, N., González-Gaitán, M., Matile, S., & Roux, A. (2018) · Nature Chemistry · doi:10.1038/s41557-018-0127-3 · Cited by 572
Fluorescence Lifetime Imaging Microscopy
Chang, C., Sud, D., & Mycek, M. (2007) · Methods in Cell Biology · doi:10.1016/s0091-679x(06)81024-1 · Cited by 195
“A two-channel confocal fluorescence lifetime microscope was used for FCS and FLIM, since the timing information down to a picosecond scale oVered the possibility not only to reconstruct fluorescence decay of each pixel for FLIM but also to analyze the fluorescence fluctuation correlation function of any single spot of…”
MethodFate of micelles and quantum dots in cells
Maysinger, D., Lovrić, J., Eisenberg, A., & Savić, R. (2007) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2006.08.011 · Cited by 160
Single‐Molecule Fluorescence Spectroscopy of Protein Folding
Schuler, B. (2005) · ChemPhysChem · doi:10.1002/cphc.200400609 · Cited by 159
Fluorescence Lifetime Imaging Microscopy for Quantitative Biological Imaging
Chen, L.-C., Lloyd, W. R., Chang, C.-W., Sud, D., & Mycek, M.-A. (2013) · Methods in Cell Biology · doi:10.1016/b978-0-12-407761-4.00020-8 · Cited by 55
Metadata
- Authors
- Wahl, M., Koberling, F., Patting, M., & Rahn, E. H.
- Venue
- Current Pharmaceutical Biotechnology
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2004-06-01
- Volume
- 5
- Issue
- 3
- Pages
- 299-308
- ISSN
- 1389-2010 (ISSN-L)
- 0000-0000
- OpenAlex
- W2066858190
- Cited by
- 78
- References
- 0
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.