The DOI matches its Crossref record.
Fluorescence Molecular Imaging of Small Animal Tumor Models
Abstract
In vivo imaging of molecular events in small animals has great potential to impact basic science and drug development. For this reason, several imaging technologies have been adapted to small animal research, including X-ray, magnetic resonance, and radioisotope imaging. Despite this plethora of visualization techniques, fluorescence imaging is emerging as an important alternative because of its operational simplicity, safety, and cost-effectiveness. Fluorescence imaging has recently become particularly interesting because of advances in fluorescent probe technology, including targeted fluorochromes as well as fluorescent "switches" sensitive to specific biochemical events. While past biological investigations using fluorescence have focused on microscopic examination of ex vivo, in vitro, or intravital specimens, techniques for macroscopic fluorescence imaging are now emerging for in vivo molecular imaging applications. This review illuminates fluorescence imaging technologies that hold promise for small animal imaging. In particular we focus on planar illumination techniques, also known as Fluorescence Reflectance Imaging (FRI), and discuss its performance and current use. We then discuss fluorescence molecular tomography (FMT), an evolving technique for quantitative three-dimensional imaging of fluorescence in vivo. This technique offers the promise of non-invasively quantifying and visualizing specific molecular activity in living subjects in three dimensions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Artificially engineered magnetic nanoparticles for ultra-sensitive molecular imaging
Lee, J.-H., Huh, Y.-M., Jun, Y.-W., Seo, J.-W., Jang, J.-T., Song, H.-T., Kim, S., Cho, E.-J., Yoon, H.-G., Suh, J.-S., et al. (2007) · Nature Medicine · doi:10.1038/nm1467 · Cited by 1,897
Designing multifunctional quantum dots for bioimaging, detection, and drug delivery
Zrazhevskiy, P., Sena, M., & Gao, X. (2010) · Chemical Society Reviews · doi:10.1039/b915139g · Cited by 997
Sharma, P., Brown, S., Walter, G., Santra, S., & Moudgil, B. (2006) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2006.05.026 · Cited by 755
The mighty mouse: genetically engineered mouse models in cancer drug development
Sharpless, N. E., & DePinho, R. A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd2110 · Cited by 661
Advanced functional materials based on polyhedral oligomeric silsesquioxane (POSS)
Tanaka, K., & Chujo, Y. (2012) · J. Mater. Chem. · doi:10.1039/c1jm14231c · Cited by 489
Metadata
- Authors
- Graves, E., Weissleder, R., & Ntziachristos, V.
- Venue
- Current Molecular Medicine
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2004-06-01
- Volume
- 4
- Issue
- 4
- Pages
- 419-430
- ISSN
- 1566-5240 (ISSN-L)
- OpenAlex
- W2157704902
- Cited by
- 213
- References
- 0
- FWCI
- 11.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescence Molecular Imaging of Small Animal Tumor Models. https://app.cochat.ai/papers/10.2174/1566524043360555
- The paper
- Graves, E., Weissleder, R., & Ntziachristos, V. (2004). Fluorescence Molecular Imaging of Small Animal Tumor Models. Current Molecular Medicine. https://doi.org/10.2174/1566524043360555
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.