The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Magnetic Nanoparticles for Cancer Therapy
Abstract
Today, technologies based on magnetic nanoparticles (MNPs) are routinely applied to biological systems with diagnostic or therapeutic purposes. The paradigmatic example is the magnetic resonance imaging (MRI), a technique that uses the magnetic moments of MNPs as a disturbance of the proton resonance to obtain images. Similarly, magnetic fluid hyperthermia (MFH) uses MNPs as heat generators to induce localized cell death. The physical basis of these techniques relies on the interaction with external magnetic fields, and therefore the magnetic moment of the particles has to be maximized for these applications. Targeted drug-delivery based on ‘smart’ nanoparticles is the next step towards more efficient oncologic therapies, by delivering a minimal dose of drug only to the vicinity of the target. Current improvements in this fields relay on a) particle functionalization with specific ligands for targeting cell membrane receptors and b) loading MNPs onto cells (e.g., dendritic cells, T-cells, macrophages) having an active role in tumor grow. Here we review the current state of research on applications of magnetic carriers for cancer therapy, discussing the advances and drawbacks of both passive and targeted delivery of MNPs. The most promising strategies for targeted delivery of MNPs are analyzed, evaluating the expected impact on clinical MRI and MFH protocols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to magnetic materials
(2009) · Materials Today · doi:10.1016/s1369-7021(09)70091-4 · Cited by 5,615
Scientific and Clinical Applications of Magnetic Carriers
(1997) · Springer eBooks · doi:10.1007/978-1-4757-6482-6 · Cited by 1,032
CRC Handbook of Biological Effects of Electromagnetic Fields
Polk, C. (2019) · CRC Press eBooks · doi:10.1201/9781351071017 · Cited by 936
MRI from A to Z: A Definitive Guide for Medical Professionals
Liney, G. P. (2010) · Digital Access to Libraries (Université catholique de Louvain (UCL), l'Université de Namur (UNamur) and the Université Saint-Louis (USL-B)) · doi:10.1007/978-1-84996-135-6 · Cited by 24
Cited by
Design and fabrication of magnetic nanoparticles for targeted drug delivery and imaging
Veiseh, O., Gunn, J. W., & Zhang, M. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.11.002 · Cited by 1,832
Magnetic fluid hyperthermia: focus on superparamagnetic iron oxide nanoparticles
Laurent, S., Dutz, S., Häfeli, U. O., & Mahmoudi, M. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2011.04.003 · Cited by 1,326
Biofunctionalized magnetic-vortex microdiscs for targeted cancer-cell destruction
Kim, D.-H., Rozhkova, E. A., Ulasov, I. V., Bader, S. D., Rajh, T., Lesniak, M. S., & Novosad, V. (2010) · Nature Materials · doi:10.1038/nmat2591 · Cited by 611
Cancer theranostics: the rise of targeted magnetic nanoparticles
Cole, A. J., Yang, V. C., & David, A. E. (2011) · Trends in Biotechnology · doi:10.1016/j.tibtech.2011.03.001 · Cited by 425
Cole, A. J., David, A. E., Wang, J., Galbán, C. J., Hill, H. L., & Yang, V. C. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.11.040 · Cited by 308
Metadata
- Authors
- Goya, G. F., Grazu, V., & Ibarra, M. R.
- Venue
- Current Nanoscience
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2008-02
- Volume
- 4
- Issue
- 1
- Pages
- 1-16
- ISSN
- 1573-4137 (ISSN-L)
- OpenAlex
- W2057855113
- Cited by
- 281
- References
- 4
- FWCI
- 8.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic Nanoparticles for Cancer Therapy. https://app.cochat.ai/papers/10.2174/157341308783591861
- The paper
- Goya, G. F., Grazu, V., & Ibarra, M. R. (2008). Magnetic Nanoparticles for Cancer Therapy. Current Nanoscience. https://doi.org/10.2174/157341308783591861
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.