CoChat

Artificial Intelligence and Its Effect on Dermatologists’ Accuracy in Dermoscopic Melanoma Image Classification: Web-Based Survey Study

Open access
Maron, Roman C, Utikal, Jochen S, Hekler, Achim, Hauschild, Axel, Sattler, Elke, Sondermann, Wiebke, Haferkamp, Sebastian, Schilling, Bastian, Heppt, Markus V, Jansen, Philipp, Reinholz, Markus, Franklin, Cindy, Schmitt, Laurenz, Hartmann, Daniela, Krieghoff-Henning, Eva, Schmitt, Max, Weichenthal, Michael, von Kalle, Christof, Fröhling, Stefan, Brinker, Titus J · 2020 · Journal of Medical Internet Research
Cited by 87

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Background: Early detection of melanoma can be lifesaving but this remains a challenge. Recent diagnostic studies have revealed the superiority of artificial intelligence (AI) in classifying dermoscopic images of melanoma and nevi, concluding that these algorithms should assist a dermatologist’s diagnoses. Objective: The aim of this study was to investigate whether AI support improves the accuracy and overall diagnostic performance of dermatologists in the dichotomous image–based discrimination between melanoma and nevus. Methods: Twelve board-certified dermatologists were presented disjoint sets of 100 unique dermoscopic images of melanomas and nevi (total of 1200 unique images), and they had to classify the images based on personal experience alone (part I) and with the support of a trained convolutional neural network (CNN, part II). Additionally, dermatologists were asked to rate their confidence in their final decision for each image. Results: While the mean specificity of the dermatologists based on personal experience alone remained almost unchanged (70.6% vs 72.4%; P=.54) with AI support, the mean sensitivity and mean accuracy increased significantly (59.4% vs 74.6%; P=.003 and 65.0% vs 73.6%; P=.002, respectively) with AI support. Out of the 10% (10/94; 95% CI 8.4%-11.8%) of cases where dermatologists were correct and AI was incorrect, dermatologists on average changed to the incorrect answer for 39% (4/10; 95% CI 23.2%-55.6%) of cases. When dermatologists were incorrect and AI was correct (25/94, 27%; 95% CI 24.0%-30.1%), dermatologists changed their answers to the correct answer for 46% (11/25; 95% CI 33.1%-58.4%) of cases. Additionally, the dermatologists’ average confidence in their decisions increased when the CNN confirmed their decision and decreased when the CNN disagreed, even when the dermatologists were correct. Reported values are based on the mean of all participants. Whenever absolute values are shown, the denominator and numerator are approximations as every dermatologist ended up rating a varying number of images due to a quality control step. Conclusions: The findings of our study show that AI support can improve the overall accuracy of the dermatologists in the dichotomous image–based discrimination between melanoma and nevus. This supports the argument for AI-based tools to aid clinicians in skin lesion classification and provides a rationale for studies of such classifiers in real-life settings, wherein clinicians can integrate additional information such as patient age and medical history into their decisions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2196/18091

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 87

Metadata

Authors
Maron, R. C., Utikal, J. S., Hekler, A., Hauschild, A., Sattler, E., Sondermann, W., Haferkamp, S., Schilling, B., Heppt, M. V., Jansen, P., Reinholz, M., Franklin, C., Schmitt, L., Hartmann, D., Krieghoff-Henning, E., Schmitt, M., Weichenthal, M., von Kalle, C., Fröhling, S., & Brinker, T. J.
Venue
Journal of Medical Internet Research
Published
2020-09-11
Volume
22
Issue
9
Pages
e18091
ISSN
1438-8871 (ISSN-L)
OpenAlex
W3085870326
Cited by
87
References
8
FWCI
3.61
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Artificial Intelligence and Its Effect on Dermatologists’ Accuracy in Dermoscopic Melanoma Image Classification: Web-Based Survey Study. https://app.cochat.ai/papers/10.2196/18091
The paper
Maron, R. C., Utikal, J. S., Hekler, A., Hauschild, A., Sattler, E., Sondermann, W., Haferkamp, S., Schilling, B., Heppt, M. V., Jansen, P., Reinholz, M., Franklin, C., Schmitt, L., Hartmann, D., Krieghoff-Henning, E., Schmitt, M., Weichenthal, M., von Kalle, C., Fröhling, S., & Brinker, T. J. (2020). Artificial Intelligence and Its Effect on Dermatologists’ Accuracy in Dermoscopic Melanoma Image Classification: Web-Based Survey Study. Journal of Medical Internet Research. https://doi.org/10.2196/18091

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.