Predicting Abnormalities in Laboratory Values of Patients in the Intensive Care Unit Using Different Deep Learning Models: Comparative Study
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Background: In recent years, the volume of medical knowledge and health data has increased rapidly. For example, the increased availability of electronic health records (EHRs) provides accurate, up-to-date, and complete information about patients at the point of care and enables medical staff to have quick access to patient records for more coordinated and efficient care. With this increase in knowledge, the complexity of accurate, evidence-based medicine tends to grow all the time. Health care workers must deal with an increasing amount of data and documentation. Meanwhile, relevant patient data are frequently overshadowed by a layer of less relevant data, causing medical staff to often miss important values or abnormal trends and their importance to the progression of the patient’s case. Objective: The goal of this work is to analyze the current laboratory results for patients in the intensive care unit (ICU) and classify which of these lab values could be abnormal the next time the test is done. Detecting near-future abnormalities can be useful to support clinicians in their decision-making process in the ICU by drawing their attention to the important values and focus on future lab testing, saving them both time and money. Additionally, it will give doctors more time to spend with patients, rather than skimming through a long list of lab values. Methods: We used Structured Query Language to extract 25 lab values for mechanically ventilated patients in the ICU from the MIMIC-III and eICU data sets. Additionally, we applied time-windowed sampling and holding, and a support vector machine to fill in the missing values in the sparse time series, as well as the Tukey range to detect and delete anomalies. Then, we used the data to train 4 deep learning models for time series classification, as well as a gradient boosting–based algorithm and compared their performance on both data sets. Results: The models tested in this work (deep neural networks and gradient boosting), combined with the preprocessing pipeline, achieved an accuracy of at least 80% on the multilabel classification task. Moreover, the model based on the multiple convolutional neural network outperformed the other algorithms on both data sets, with the accuracy exceeding 89%. Conclusions: In this work, we show that using machine learning and deep neural networks to predict near-future abnormalities in lab values can achieve satisfactory results. Our system was trained, validated, and tested on 2 well-known data sets to ensure that our system bridged the reality gap as much as possible. Finally, the model can be used in combination with our preprocessing pipeline on real-life EHRs to improve patients’ diagnosis and treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures










Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Models based on longitudinal EHRs, physiological signals, and laboratory trends estimate individual risk profiles for mortality and complications in both inpatient and outpatient settings [7,15].”
From Artificial Intelligence in Clinical Decision-Making: A Comprehensive Review of Diagnostic, Prognostic, and Therapeutic Applications, Validation Gaps, Bias, and Deployment Challenges (2026) · cites this paper as [7]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Predictive models estimate hospital admissions, length of stay, and discharge timing using historical utilisation patterns and real-time clinical data [7].”
From Artificial Intelligence in Clinical Decision-Making: A Comprehensive Review of Diagnostic, Prognostic, and Therapeutic Applications, Validation Gaps, Bias, and Deployment Challenges (2026) · cites this paper as [7]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These models incorporate demographic characteristics, comorbidities, prior hospitalisation, and treatment history to support discharge planning and care coordination [7].”
From Artificial Intelligence in Clinical Decision-Making: A Comprehensive Review of Diagnostic, Prognostic, and Therapeutic Applications, Validation Gaps, Bias, and Deployment Challenges (2026) · cites this paper as [7]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The widespread adoption of EHR systems has enabled the development of predictive models using longitudinal patient data [6,7].”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hochreiter, S., & Schmidhuber, J. (1997) · Neural Computation · doi:10.1162/neco.1997.9.8.1735 · Cited by 102,318
nnU-Net: a self-configuring method for deep learning-based biomedical image segmentation
Isensee, F., Jaeger, P. F., Kohl, S. A. A., Petersen, J., & Maier-Hein, K. H. (2021) · Nature Methods · doi:10.1038/s41592-020-01008-z · Cited by 10,477
(2012) · Cited by 9,062
MIMIC-III, a freely accessible critical care database
Johnson, A. E. W., Pollard, T. J., Shen, L., Lehman, L.-W. H., Feng, M., Ghassemi, M., Moody, B., Szolovits, P., Anthony Celi, L., & Mark, R. G. (2016) · Scientific Data · doi:10.1038/sdata.2016.35 · Cited by 8,141
Digital Signal Processing : A Computer-Based Approach
Mitra, S. (1997) · Cited by 2,115
Pollard, T. J., Johnson, A. E. W., Raffa, J. D., Celi, L. A., Mark, R. G., & Badawi, O. (2018) · Scientific Data · doi:10.1038/sdata.2018.178 · Cited by 1,993
Time-series forecasting with deep learning: a survey
Lim, B., & Zohren, S. (2021) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2020.0209 · Cited by 1,787
Multitask learning and benchmarking with clinical time series data
Harutyunyan, H., Khachatrian, H., Kale, D. C., Ver Steeg, G., & Galstyan, A. (2019) · Scientific Data · doi:10.1038/s41597-019-0103-9 · Cited by 958 · cited 2×
“The benchmarking tasks include predicting mortality (classification), length of stay (regression), phenotyping (multilabel classification), and decompensation (time series classification) [16].”
Matsugu, M., Mori, K., Mitari, Y., & Kaneda, Y. (2003) · Neural Networks · doi:10.1016/s0893-6080(03)00115-1 · Cited by 715
Natural Language Processing of Clinical Notes on Chronic Diseases: Systematic Review
Sheikhalishahi, S., Miotto, R., Dudley, J. T., Lavelli, A., Rinaldi, F., & Osmani, V. (2019) · JMIR Medical Informatics · doi:10.2196/12239 · Cited by 558 · cited 2×
“The models are explained in more detail in Multimedia Appendix 2 [2,27-39].”
Research works printed but not linked: 6
- Moor, M, 2019, Proceedings of the 4th Machine Learning for Healthcare Conference, PMLR, 106, 2
- VaswaniAShazeerNParmarNUszkoreitJJonesLGomezANKaiserLPolosukhinIAttention is all you needProceedings of the Advances in Neural Information Processing Systems201731st Conference on Neural Information Processing Systems (NIPS 2017)December 4-9, 2017Long Beach, CA, United StatesCurran Associates, Inc
- Kazemi, M, ArXiv
- Lea, C, 2016, Computer Vision – ECCV 2016 Workshops. ECCV 2016. Lecture Notes in Computer Science
- KeGMengQFinleyTWangTChenWMaWLiuTYLightGBM: a highly efficient gradient boosting decision treeProceedings of the Advances in Neural Information Processing Systems201731st Conference on Neural Information Processing Systems (NIPS 2017)December 4-9, 2017Long Beach, CA, United StatesCurran Associates, Inc
- MaasALHannunAYNgAYRectifier nonlinearities improve neural network acoustic modelsProceedings of the 30th International Conference on Machine Learning20130630th International Conference on Machine LearningJune 17-19, 2013Atlanta, Georgia, United States
Cited by
Bashiri, F. S., Carey, K. A., Martin, J., Koyner, J. L., Edelson, D. P., Gilbert, E. R., Mayampurath, A. M., Afshar, M., & Churpek, M. M. (2024) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocae088 · Cited by 18
Barhoush, M., Ayad, A., & Schmeink, A. (2023) · International Conference on Electrical, Computer, Communications and Mechatronics Engineering (ICECCME) · doi:10.1109/iceccme57830.2023.10253070 · Cited by 8
Self-citationMachine learning-based error detection in the clinical laboratory: a critical review
Lin, Y., Mensah, I. K., Doering, M. M., Shean, R. C., & Spies, N. C. (2025) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2025.2512468 · Cited by 6
Emerging anomaly detection techniques for electronic health records: A survey
Bhanja, S. N., Niu, H., Chen, Y., Omitaomu, O. A., Laurio, A., Trickey, A. W., Sampath, V., & Nebeker, J. R. (2026) · Intelligence-Based Medicine · doi:10.1016/j.ibmed.2026.100349 · Cited by 5
Ayad, A., Tai, Y.-H., Dartmann, G., & Schmeink, A. (2024) · IEEE Access · doi:10.1109/access.2024.3414184 · Cited by 5
Self-citation
Metadata
- Authors
- Ayad, A., Hallawa, A., Peine, A., Martin, L., Fazlic, L. B., Dartmann, G., Marx, G., & Schmeink, A.
- Affiliations
- RWTH Aachen University (DE)
- Universitätsklinikum Aachen (DE)
- Trier University of Applied Sciences (DE)
- Corresponding author
- Ayad, Ahmad
- ORCID
- Venue
- JMIR Medical Informatics
- Publisher
- JMIR Publications Inc.
- Published
- 2022-08-24
- Volume
- 10
- Issue
- 8
- Pages
- e37658
- ISSN
- 2291-9694 (ISSN-L)
- PMC
- PMC9453586
- OpenAlex
- W4292953849
- Semantic Scholar
- afe1c70c0f12ee53381c3d0bcf6a36f45566d38f
- Cited by
- 14
- References
- 31
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 5 · 2023: 1
- FWCI
- 0.91
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- JMIR Medical Informatics (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- RWTH Publications (RWTH Aachen) (submittedVersion, other-oa)
- RWTH Publications (RWTH Aachen)
- Topics
- Physical Sciences › Computer Science › Artificial Intelligence › Machine Learning in Healthcare
- Physical Sciences › Computer Science › Artificial Intelligence › Anomaly Detection Techniques and Applications
- Physical Sciences › Computer Science › Signal Processing › Time Series Analysis and Forecasting
- Keywords
- intensive care unit patients, mechanical ventilation, time series classification, multi-label classification, convolutional neural networks, gradient boosting, electronic health records, MIMIC-III, eICU, missing data imputation, clinical decision support, deep learning model comparison, data preprocessing pipeline
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.