Clinical Efficacy of Deep Transcranial Magnetic Stimulation in Psychiatric and Cognitive Disorders: Protocol for a Systematic Review
Open accessPublished version of a preprint
The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
Abstract
Background: Transcranial magnetic stimulation (TMS) is a widely used noninvasive brain stimulation technique for psychiatric and cognitive disorders. In recent years, deep TMS (dTMS) has shown promise as an enhanced form of TMS able to stimulate deeper brain structures and target broader networks. Various magnetic Hesed-coil (H-coil) designs—a novel feature of dTMS—have been used to stimulate brain regions implicated in the pathophysiology of specific psychiatric and cognitive disorders, thereby producing therapeutic effects. Given the novelty of dTMS in psychiatry, little is known about the clinical efficacy of dTMS across psychiatric and cognitive disorders—that is, whether dTMS performs superiorly to sham or control. Objective: In this paper, we outline a protocol for a systematic review investigating the clinical efficacy of dTMS. The primary objective is to conduct a systematic review of the literature on dTMS for psychiatric and cognitive disorders and, if feasible, a meta-analysis to compare the efficacy of active dTMS versus sham/control for psychiatric disorders. Dementia and related cognitive disorders will also be examined. A secondary objective will be to examine subgroup differences (by age, sex, H-coil design, and dTMS parameters [ie, pulses per session, percentage of motor threshold, etc]) to evaluate whether dTMS differentially influences clinical outcomes based on these factors. Methods: A comprehensive search of the APA PsycINFO, Embase, MEDLINE, and PubMed databases will be conducted using keywords such as “H-coil” and “dTMS.” Two authors (AD and MD) will be responsible for screening relevant articles, assessing article eligibility (according to predetermined inclusion and exclusion criteria), and data extraction. All included articles will undergo a quality and risk of bias assessment. Data from included articles will be summarized qualitatively in a systematic review. If a sufficient number of equivalent studies are available, a meta-analysis will be performed to (1) determine the effect of active versus sham dTMS (or another control arm) across psychiatric and cognitive disorders, and (2) examine subgroup effects of clinical outcomes. Results: The preliminary search rendered a total of 1134 articles from the APA PsycINFO, Embase, and MEDLINE databases. After full-text screening, 21 eligible articles remained. One additional article was identified from the references section of an existing systematic review. In total, 22 eligible articles were included. Data extraction and quality of assessment procedures are ongoing. Conclusions: We will outline the evidence relating to the clinical efficacy of dTMS in various psychiatric and cognitive disorders. The results of the prospective systematic review will provide clinicians with valuable insight into the clinical (ie, participant age, sex, psychiatric or cognitive disorder, etc) and methodological factors (ie, H-coil design, dTMS parameters, etc) which may contribute to dTMS efficacy, and thereby may assist clinicians in their decision to prescribe dTMS for specific psychiatric and cognitive disorders. Trial Registration: PROSPERO CRD42022360066; https://tinyurl.com/5ev6byrn International Registered Report Identifier (IRRID): DERR1-10.2196/45213
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Deep TMS (dTMS), utilizes H-coils to extend this stimulation to deeper targets, while also offering more favorable safety and tolerability profiles [6,100,101,102,103,104,105].”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [6]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“It represents the strongest endogenous magnetic signal in the human body, up to 100 times stronger than the brain’s [5,6]”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [6]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“It represents the strongest endogenous magnetic signal in the human body, up to 100 times stronger than the brain’s [5,6]”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [6]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & The PRISMA Group (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000097 · Cited by 64,042 · cited 1×
“Articles will be screened in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) [60] guidelines.”
MethodWang, G., Ma, R., Qiao, G., Wada, K., Aizawa, Y., & Satoh, T. (2015) · Integrative Medicine International · doi:10.1159/000368408 · Cited by 18,657
GRADE guidelines: 3. Rating the quality of evidence
Balshem, H., Helfand, M., Schünemann, H. J., Oxman, A. D., Kunz, R., Brozek, J., Vist, G. E., Falck-Ytter, Y., Meerpohl, J., & Norris, S. (2011) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2010.07.015 · Cited by 8,285 · cited 2×
“All articles will be assessed according to the grading of recommendations, assessment, development, and evaluations (GRADE) checklist [61,62] to evaluate the quality of data and risk of bias.”
MethodRush, A. J., George, M. S., Sackeim, H. A., Marangell, L. B., Husain, M. M., Giller, C., Nahas, Z., Haines, S., Simpson, R. K., & Goodman, R. (2000) · Biological Psychiatry · doi:10.1016/s0006-3223(99)00304-2 · Cited by 688 · cited 1×
“Research on other therapy options, such as vagus nerve stimulation [33,34] and deep brain stimulation [35-37], have continued to accumulate, offering further insight into these treatment options for psychiatric disorders.”
Meader, N., King, K., Llewellyn, A., Norman, G., Brown, J., Rodgers, M., Moe-Byrne, T., Higgins, J. P., Sowden, A., & Stewart, G. (2014) · Systematic Reviews · doi:10.1186/2046-4053-3-82 · Cited by 610 · cited 2×
“All articles will be assessed according to the grading of recommendations, assessment, development, and evaluations (GRADE) checklist [61,62] to evaluate the quality of data and risk of bias.”
MethodZhdanava, M., Pilon, D., Ghelerter, I., Chow, W., Joshi, K., Lefebvre, P., & Sheehan, J. J. (2021) · The Journal of Clinical Psychiatry · doi:10.4088/jcp.20m13699 · Cited by 523 · cited 1×
“In particular, treatment resistance occurs in approximately one third of patients with major depressive disorder [9,10], 30%-60% of patients with schizophrenia [11-13], and 40%-60% of patients with obsessive-compulsive disorder [14,15].”
BackgroundTranscranial magnetic stimulation of deep brain regions: evidence for efficacy of the H-Coil
Zangen, A., Roth, Y., Voller, B., & Hallett, M. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.11.008 · Cited by 473 · cited 2×
“While traditional TMS figure-8 coils generally stimulate subdural cortical targets up to 0.7 cm [44], dTMS target areas are up to 4 cm beneath the surface depending on the chosen H-coil [45].”
BackgroundInfluentialCarmi, L., Tendler, A., Bystritsky, A., Hollander, E., Blumberger, D. M., Daskalakis, J., Ward, H., Lapidus, K., Goodman, W., Casuto, L., et al. (2019) · American Journal of Psychiatry · doi:10.1176/appi.ajp.2019.18101180 · Cited by 458 · cited 1×
“…the findings of recent dTMS clinical trials in patients with various psychiatric and cognitive disorders, including Alzheimer disease [55], attention-deficit or hyperactivity disorder [56], obsessive-compulsive disorder [57], posttraumatic stress disorder [58], and substance use disorder [59].”
Background
Research works printed but not linked: 1
- GaynesBNAsherGGartlehnerGHoffmanVGreenJBolandELuxLWeberRPRandolphCBannCCoker-SchwimmerEViswanathanMLohrKNDefinition of treatment-resistant depression in the medicare populationAHRQ Technology Assessments20182022-09-28Rockville (MD)Agency for Healthcare Research and Quality (US)http://www.ncbi.nlm.nih.gov/books/NBK526366/
Cited by
Clinical development and guiding theory of transcranial magnetic stimulation: a literature review
Lin, Z., Cheng, J.-L., Tan, C., Liu, Z., & Han, D. (2025) · Annals of Medicine · doi:10.1080/07853890.2025.2581921 · Cited by 5
“In addition, there are many versions of TMS coils for the same class. for example, there are nearly 30 different types of hesed coil, which are designed to reflect different subdural depths, stimulation volumes, and stimulation areas to meet the needs of different diseases [100].”
Palantzas, A., & Anagnostouli, M. (2026) · Sensors · doi:10.3390/s26051738 · Cited by 1
Kievišienė, J. (2026) · Lithuanian University of Health Sciences
Metadata
- Authors
- Di Passa, A.-M., Dabir, M., Fein, A., Khoshroo, S., McIntyre-Wood, C., Marsden, E., MacKillop, E., De Jesus, J., MacKillop, J., & Duarte, D.
- Affiliations
- McMaster University (CA)
- Peter Boris Centre for Addictions Research (CA)
- Corresponding author
- Duarte, Dante
- ORCID
- Venue
- JMIR Research Protocols
- Publisher
- JMIR Publications Inc.
- Published
- 2023-05-26
- Volume
- 12
- Pages
- e45213
- ISSN
- 1929-0748 (ISSN-L)
- PMC
- PMC10257110
- OpenAlex
- W4367336381
- Cited by
- 2
- References
- 64
- Citations by year
- 2026: 1 · 2025: 1
- FWCI
- 0.05
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- JMIR Research Protocols (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Medical Research Council
- National Medical Research Council
- Topics
- Life Sciences › Neuroscience › Neurology › Transcranial Magnetic Stimulation Studies
- Health Sciences › Medicine › Psychiatry and Mental health › Electroconvulsive Therapy Studies
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Keywords
- deep transcranial magnetic stimulation, H-coil, mental illness, cognitive disorders, dementia, subgroup analysis, stimulation parameters, motor threshold, non-invasive brain stimulation, clinical efficacy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.