Comparison of Physical Activity Measures Using Mobile Phone-Based CalFit and Actigraph
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Epidemiological studies on physical activity often lack inexpensive, objective, valid, and reproducible tools for measuring physical activity levels of participants. Novel sensing technologies built into smartphones offer the potential to fill this gap. OBJECTIVE: We sought to validate estimates of physical activity and determine the usability for large population-based studies of the smartphone-based CalFit software. METHODS: A sample of 36 participants from Barcelona, Spain, wore a smartphone with CalFit software and an Actigraph GT3X accelerometer for 5 days. The ease of use (usability) and physical activity measures from both devices were compared, including vertical axis counts (VT) and duration and energy expenditure predictions for light, moderate, and vigorous intensity from Freedson's algorithm. Statistical analyses included (1) Kruskal-Wallis rank sum test for usability measures, (2) Spearman correlation and linear regression for VT counts, (3) concordance correlation coefficient (CCC), and (4) Bland-Altman plots for duration and energy expenditure measures. RESULTS: Approximately 64% (23/36) of participants were women. Mean age was 31 years (SD 8) and mean body mass index was 22 kg/m(2) (SD 2). In total, 25/36 (69%) participants recorded at least 3 days with at least 10 recorded hours of physical activity using CalFit. The linear association and correlations for VT counts were high (adjusted R(2)=0.85; correlation coefficient .932, 95% CI 0.931-0.933). CCCs showed high agreement for duration and energy expenditure measures (from 0.83 to 0.91). CONCLUSIONS: The CalFit system had lower usability than the Actigraph GT3X because the application lacked a means to turn itself on each time the smartphone was powered on. The CalFit system may provide valid estimates to quantify and classify physical activity. CalFit may prove to be more cost-effective and easily deployed for large-scale population health studies than other specialized instruments because cell phones are already carried by many people.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825 · cited 2×
“To maximize the comparability [16], the intensity of physical activity measured in metabolic equivalents (METs) by both devices was calculated according to the equation of Freedson et al [17], which uses a linear function based on vertical axis counts to produce their estimates: ActiGraph GT3X METs=1.439008 + (0.00079…”
MethodInfluentialPrince, S. A., Adamo, K. B., Hamel, M., Hardt, J., Connor Gorber, S., & Tremblay, M. (2008) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-5-56 · Cited by 3,162
Conducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
Validation and comparison of ActiGraph activity monitors
Sasaki, J. E., John, D., & Freedson, P. S. (2011) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2011.04.003 · Cited by 1,317
Increasing Physical Activity With Mobile Devices: A Meta-Analysis
Fanning, J., Mullen, S. P., & McAuley, E. (2012) · Journal of Medical Internet Research · doi:10.2196/jmir.2171 · Cited by 457 · cited 3×
“Beyond the current CalFit application, which is focused on unobtrusive sensing of physical activity, may be novel mHealth smartphone applications that not only record physical activity, but attempt to intervene upon behavior [11,21].”
BackgroundClassification Accuracies of Physical Activities Using Smartphone Motion Sensors
Wu, W., Dasgupta, S., Ramirez, E. E., Peterson, C., & Norman, G. J. (2012) · Journal of Medical Internet Research · doi:10.2196/jmir.2208 · Cited by 316
Pratt, M., Sarmiento, O. L., Montes, F., Ogilvie, D., Marcus, B. H., Perez, L. G., & Brownson, R. C. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60736-3 · Cited by 295
Lyden, K., Kozey, S. L., Staudenmeyer, J. W., & Freedson, P. S. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1639-8 · Cited by 222 · cited 1×
“Second, the use of the Actigraph GT3X accelerometer as a gold standard could be seen as a limitation, but it is the reference tool for assessing physical activity in real life for 5 days and has well-established validity [30].”
MethodModeling Physical Activity Outcomes from Wearable Monitors
HEIL, D. P., BRAGE, S., & ROTHNEY, M. P. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399dcc · Cited by 121 · cited 1×
“The American College of Sports Medicine considers having at least 3 days with at least 10 hours of recorded activity as a valid assessment of physical activity [18].”
Background
Cited by
Outdoor blue spaces, human health and well-being: a systematic review of quantitative studies
Gascon, M., Zijlema, W., Vert, C., White, M. P., & Nieuwenhuijsen, M. J. (2017) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2017.08.004 · Cited by 769
Self-citationMeasuring and Influencing Physical Activity with Smartphone Technology: A Systematic Review
Bort-Roig, J., Gilson, N. D., Puig-Ribera, A., Contreras, R. S., & Trost, S. G. (2014) · Sports Medicine · doi:10.1007/s40279-014-0142-5 · Cited by 557
Sullivan, A. N., & Lachman, M. E. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2016.00289 · Cited by 458
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
Nieuwenhuijsen, M. J. (2016) · Environmental Health · doi:10.1186/s12940-016-0108-1 · Cited by 332
Self-citation
Metadata
- Authors
- Donaire-Gonzalez, D., de Nazelle, A., Seto, E., Mendez, M., Nieuwenhuijsen, M. J., & Jerrett, M.
- Venue
- Journal of Medical Internet Research
- Publisher
- JMIR Publications Inc.
- Published
- 2013-06-13
- Volume
- 15
- Issue
- 6
- Pages
- e111
- ISSN
- 1438-8871 (ISSN-L)
- OpenAlex
- W2014898932
- Cited by
- 56
- References
- 9
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Physical Activity Measures Using Mobile Phone-Based CalFit and Actigraph. https://app.cochat.ai/papers/10.2196/jmir.2470
- The paper
- Donaire-Gonzalez, D., de Nazelle, A., Seto, E., Mendez, M., Nieuwenhuijsen, M. J., & Jerrett, M. (2013). Comparison of Physical Activity Measures Using Mobile Phone-Based CalFit and Actigraph. Journal of Medical Internet Research. https://doi.org/10.2196/jmir.2470
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.