CoChat

Integrating mHealth in Oncology: Experience in the Province of Trento

Open access
Galligioni, Enzo, Piras, Enrico Maria, Galvagni, Michele, Eccher, Claudio, Caramatti, Silvia, Zanolli, Daniela, Santi, Jonni, Berloffa, Flavio, Dianti, Marco, Maines, Francesca, Sannicolò, Mirella, Sandri, Marco, Bragantini, Lara, Ferro, Antonella, Forti, Stefano · 2015 · Journal of Medical Internet Research
Cited by 46

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The potential benefits of the introduction of electronic and mobile health (mHealth) information technologies, to support the safe delivery of intravenous chemotherapy or oral anticancer therapies, could be exponential in the context of a highly integrated computerized system. OBJECTIVE: Here we describe a safe therapy mobile (STM) system for the safe delivery of intravenous chemotherapy, and a home monitoring system for monitoring and managing toxicity and improving adherence in patients receiving oral anticancer therapies at home. METHODS: The STM system is fully integrated with the electronic oncological patient record. After the prescription of chemotherapy, specific barcodes are automatically associated with the patient and each drug, and a bedside barcode reader checks the patient, nurse, infusion bag, and drug sequence in order to trace the entire administration process, which is then entered in the patient's record. The usability and acceptability of the system was investigated by means of a modified questionnaire administered to nurses. The home monitoring system consists of a mobile phone or tablet diary app, which allows patients to record their state of health, the medications taken, their side effects, and a Web dashboard that allows health professionals to check the patient data and monitor toxicity and treatment adherence. A built-in rule-based alarm module notifies health care professionals of critical conditions. Initially developed for chronic patients, the system has been subsequently customized in order to monitor home treatments with capecitabine or sunitinib in cancer patients (Onco-TreC). RESULTS: The STM system never failed to match the patient/nurse/drug sequence association correctly, and proved to be accurate and reliable in tracing and recording the entire administration process. The questionnaires revealed that the users were generally satisfied and had a positive perception of the system's usefulness and ease of use, and the quality of their working lives. The pilot studies with the home monitoring system with 43 chronic patients have shown that the approach is reliable and useful for clinicians and patients, but it is also necessary to pay attention to the expectations that mHealth solutions may raise in users. The Onco-TreC version has been successfully laboratory tested, and is now ready for validation. CONCLUSIONS: The STM and Onco-TreC systems are fully integrated with our complex and composite information system, which guarantees privacy, security, interoperability, and real-time communications between patients and health professionals. They need to be validated in order to confirm their positive contribution to the safer administration of anticancer drugs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2196/jmir.3743

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 46

Metadata

Authors
Galligioni, E., Piras, E. M., Galvagni, M., Eccher, C., Caramatti, S., Zanolli, D., Santi, J., Berloffa, F., Dianti, M., Maines, F., Sannicolò, M., Sandri, M., Bragantini, L., Ferro, A., & Forti, S.
Venue
Journal of Medical Internet Research
Published
2015-05-13
Volume
17
Issue
5
Pages
e114
ISSN
1438-8871 (ISSN-L)
OpenAlex
W2119147452
Cited by
46
References
9
FWCI
10.52
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.