Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 160

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Adoption Factors of the Electronic Health Record: A Systematic Review

Open access
Kruse, Clemens Scott, Kothman, Krysta, Anerobi, Keshia, Abanaka, Lillian·2016·JMIR Medical Informatics

Abstract

BACKGROUND: The Health Information Technology for Economic and Clinical Health (HITECH) was a significant piece of legislation in America that served as a catalyst for the adoption of health information technology. Following implementation of the HITECH Act, Health Information Technology (HIT) experienced broad adoption of Electronic Health Records (EHR), despite skepticism exhibited by many providers for the transition to an electronic system. A thorough review of EHR adoption facilitator and barriers provides ongoing support for the continuation of EHR implementation across various health care structures, possibly leading to a reduction in associated economic expenditures. OBJECTIVE: The purpose of this review is to compile a current and comprehensive list of facilitators and barriers to the adoption of the EHR in the United States. METHODS: Authors searched Cumulative Index of Nursing and Allied Health Literature (CINAHL) and MEDLINE, 01/01/2012-09/01/2015, core clinical/academic journals, MEDLINE full text, and evaluated only articles germane to our research objective. Team members selected a final list of articles through consensus meetings (n=31). Multiple research team members thoroughly read each article to confirm applicability and study conclusions, thereby increasing validity. RESULTS: Group members identified common facilitators and barriers associated with the EHR adoption process. In total, 25 adoption facilitators were identified in the literature occurring 109 times; the majority of which were efficiency, hospital size, quality, access to data, perceived value, and ability to transfer information. A total of 23 barriers to adoption were identified in the literature, appearing 95 times; the majority of which were cost, time consuming, perception of uselessness, transition of data, facility location, and implementation issues. CONCLUSIONS: The 25 facilitators and 23 barriers to the adoption of the EHR continue to reveal a preoccupation on cost, despite incentives in the HITECH Act. Limited financial backing and outdated technology were also common barriers frequently mentioned during data review. Future public policy should include incentives commensurate with those in the HITECH Act to maintain strong adoption rates.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2196/medinform.5525

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 160

Metadata

Authors
Kruse, C. S., Kothman, K., Anerobi, K., & Abanaka, L.
Venue
JMIR Medical Informatics
Published
2016-06-01
Volume
4
Issue
2
Pages
e19
ISSN
2291-9694 (ISSN-L)
OpenAlex
W2418503617
Cited by
160
References
2
FWCI
3.42
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Adoption Factors of the Electronic Health Record: A Systematic Review. https://app.cochat.ai/papers/10.2196/medinform.5525
The paper
Kruse, C. S., Kothman, K., Anerobi, K., & Abanaka, L. (2016). Adoption Factors of the Electronic Health Record: A Systematic Review. JMIR Medical Informatics. https://doi.org/10.2196/medinform.5525

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.