Cited by 88Mobile Health and mHealth ApplicationsOsteoarthritis Treatment and MechanismsMusculoskeletal pain and rehabilitation

Assessing the Impact of a Novel Smartphone Application Compared With Standard Follow-Up on Mobility of Patients With Knee Osteoarthritis Following Treatment With Hylan G-F 20: A Randomized Controlled Trial

Open access
Skrepnik, Nebojsa, Spitzer, Andrew, Altman, Roy, Hoekstra, John, Stewart, John, Toselli, Richard·2017·JMIR mHealth and uHealth

Abstract

BACKGROUND: Osteoarthritis (OA) is a leading cause of disability in the United States. Although no disease-modifying therapies exist, patients with knee OA who increase walking may reduce risk of functional limitations. OBJECTIVE: The objective of the study is to evaluate the impact of a mobile app (OA GO) plus wearable activity monitor/pedometer (Jawbone UP 24) used for 90 days on the mobility of patients with knee OA treated with hylan G-F 20. METHODS: were excluded. All patients received a single 6-mL injection of hylan G-F 20 and wore the Jawbone monitor. The patients were then randomized 1:1 to Jawbone and OA GO (Group A; n=107) with visible feedback (unblinded) or Jawbone only (Group B; n=104) with no visible feedback (blinded). The primary endpoint was mean change from baseline in steps per day at day 90 between Groups A and B. RESULTS: Baseline characteristics were similar between groups. There were significant differences between the increases in least squares (LS) mean number of steps per day (1199 vs 467, P=.03) and the mean percentage change (35.8% vs 11.5%, P=.02) from baseline in favor of Group A over Group B. There was a greater reduction in pain from baseline during the 6-minute walk test in Group A versus Group B. (LS mean change: -55.3 vs -33.8, P=.007). Most patients (65.4%) and surveys of physicians (67.3%) reported they would be likely or very likely to use/recommend the devices. Patient Activity Measure-13 scores improved from baseline (LS mean change for Groups A and B: 5.0 vs 6.9), with no significant differences between groups. The occurrence of adverse events was similar in the 2 groups. CONCLUSIONS: Use of a novel smartphone app in conjunction with a wearable activity monitor provided additional improvement on mobility parameters such as steps per day and pain with walking in the 6-minute walk test in patients with knee OA who were treated with hylan G-F 20. Results also highlight the amenability of patients and physicians to using mobile health technology in the treatment of OA and suggest further study is warranted.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2196/mhealth.7179

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • 1 study [22] was judged as high risk for other sources of bias because of conflicts of interest declared by the authors.

    “and 1 study [22] was judged as high risk for other sources of bias because of conflicts of interest declared by the authors.”

    From Consumer-based wearable activity trackers increase physical activity participation: systematic review and meta-analysis (2019) · cites this paper as [22]

    The Methods (Study Population and Study Design; page unavailable) identify this as the trial and mention a study sponsor. The high-risk judgment is the citing authors’ own assessment, but our copy does not show the authors’ declared conflicts of interest that the sentence gives as its basis; searches for conflicts, disclosures, and funding did not locate them. (LLM, conf=0.70)

    Experimental — accuracy not yet measured
  • Randomized controlled trials have shown that consumer-based wearable activity trackers have promise in relation to increasing physical activity participation.

    “Randomized controlled trials have shown that these devices have promise in relation to increasing physical activity participation [21,22]”

    From Consumer-based wearable activity trackers increase physical activity participation: systematic review and meta-analysis (2019) · cites this paper as [22]

    The Results > Mobility and Pain section (page unavailable) reports a significantly greater increase in daily steps in the intervention group, supporting the claim that this approach has promise. However, the Methods > Study Design section shows that patients received both a wearable tracker and a smartphone app, while the comparison group also wore a tracker without access to its data. The trial therefore does not establish an effect of consumer wearable trackers alone, and its participants were patients with knee osteoarthritis rather than a general population. (LLM, conf=0.86)

    Experimental — accuracy not yet measured
  • Actual wear time of the activity tracker varied, ranging from over 90% wear time to all participants ceasing to wear the device by the end of the intervention.

    “Actual wear time of the activity tracker varied, ranging from over 90% wear time [21,22] to all participants ceasing to wear the device by the end of the intervention [32] as the study design allowed self-directed wear of the activity tracker.”

    From Consumer-based wearable activity trackers increase physical activity participation: systematic review and meta-analysis (2019) · cites this paper as [22]

    The Results section (Patient Disposition, Baseline Characteristics, and Adherence; page unavailable) reports that 91.0% of patients were compliant, defined as wearing the monitor at least 80% of the time. That does not establish over 90% actual wear time. The claim that all participants stopped wearing a device is attached to a different citation, not this paper. (LLM, conf=0.87)

    Experimental — accuracy not yet measured
  • A total of 26 studies were included across all meta-analyses.

    “A total of 26 studies were included across all meta-analyses [21,22,29-48,50-53].”
  • 17 studies reported activity tracker adherence data, with 13 of these reporting activity tracker wear on at least 50% of the study intervention days.

    “Moreover, 17 studies reported activity tracker adherence data [21,22,30,32,34,35, 37,38,40,41,43-45,50-52,54], with 13 of these studies [21,22,30,34,35,40,41,43,44,50-52,54] reporting activity tracker wear on at least 50% of the study intervention days.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 51 · Cited by 88

Authors
Skrepnik, N., Spitzer, A., Altman, R., Hoekstra, J., Stewart, J., & Toselli, R.
Affiliations
  • Tucson Orthopaedic Institute (US)
  • Cedars-Sinai Medical Center (US)
  • University of California, Los Angeles (US)
  • National Clinical Research (US)
  • Sanofi (Canada) (CA)
  • Sanofi (France) (FR)
Corresponding author
Skrepnik, Nebojsa
Venue
JMIR mHealth and uHealth
Published
2017-05-09
Volume
5
Issue
5
Pages
e64
ISSN
2291-5222 (ISSN-L)
OpenAlex
W2612207358
Cited by
88
References
51
Citations by year
2026: 2 · 2025: 7 · 2024: 11 · 2023: 15 · 2022: 17 · 2021: 10 · 2020: 13 · 2019: 4 · 2018: 9
FWCI
10.99
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • JMIR mhealth and uhealth (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
  • Health Sciences › Medicine › Rheumatology › Osteoarthritis Treatment and Mechanisms
  • Health Sciences › Medicine › Pharmacology › Musculoskeletal pain and rehabilitation
Keywords
hylan G-F 20, hyaluronic acid injection, mobile health, mobile application, wearable activity trackers, pedometers, physical activity, walking steps, 6-minute walk test, patient activity, technology acceptance, follow-up care

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review