The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Clinical Study of a Wearable Remote Rehabilitation Training System for Patients With Stroke: Randomized Controlled Pilot Trial (Preprint)
Open accessPreprint — published as 10.2196/40416 · Paper page
Abstract
BACKGROUND: In contrast to the large and increasing number of patients with stroke, clinical rehabilitation resources cannot meet their rehabilitation needs. Especially for those discharged, ways to carry out effective rehabilitation training without the supervision of physicians and receive guidance from physicians remain urgent problems to be solved in clinical rehabilitation and have become a research hot spot at home and abroad. At present, there are many studies on home rehabilitation training based on wearable devices, Kinect, among others, but these have disadvantages (eg, complex systems, high price, and unsatisfactory rehabilitation effects). OBJECTIVE: This study aims to design a remote intelligent rehabilitation training system based on wearable devices and human-computer interaction training tasks, and to evaluate the effectiveness and safety of the remote rehabilitation training system for nonphysician-supervised motor rehabilitation training of patients with stroke through a clinical trial study. METHODS: A total of 120 inpatients with stroke having limb motor dysfunction were enrolled via a randomized, parallel-controlled method in the rehabilitation institutions, and a 3-week clinical trial was conducted in the rehabilitation hall with 60 patients in the experimental group and 60 in the control group. The patients in the experimental group used the remote rehabilitation training system for rehabilitation training and routine clinical physical therapy (PT) training and received routine drug treatment every day. The patients in the control group received routine clinical occupational therapy (OT) training and routine clinical PT training and routine drug treatment every day. At the beginning of the training (baseline) and after 3 weeks, the Fugl-Meyer Motor Function Rating scale was scored by rehabilitation physicians, and the results were compared and analyzed. RESULTS: Statistics were performed using SAS software (version 9.4). The total mean Fugl-Meyer score improved by 11.98 (SD 8.46; 95% CI 9.69-14.27) in the control group and 17.56 (SD 11.65; 95% CI 14.37-20.74) in the experimental group, and the difference between the 2 groups was statistically significant (P=.005). Among them, the mean Fugl-Meyer upper extremity score improved by 7.45 (SD 7.24; 95% CI 5.50-9.41) in the control group and 11.28 (SD 8.59; 95% CI 8.93-13.62) in the experimental group, and the difference between the 2 groups was statistically significant (P=.01). The mean Fugl-Meyer lower extremity score improved by 4.53 (SD 4.42; 95% CI 3.33-5.72) in the control group and 6.28 (SD 5.28; 95% CI 4.84-7.72) in the experimental group, and there was no significant difference between the 2 groups (P=.06). The test results showed that the experimental group was better than the control group, and that the patients’ motor ability was improved. CONCLUSIONS: The remote rehabilitation training system designed based on wearable devices and human-computer interaction training tasks can replace routine clinical OT training. In the future, through medical device registration certification, the system will be used without the participation of physicians or therapists, such as in rehabilitation training halls, and in remote environments, such as communities and homes. CLINICALTRIAL: Chinese Clinical Trial Registry ChiCTR2200061310; https://tinyurl.com/34ka2725
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Convolutional and LSTM Recurrent Neural Networks for Multimodal Wearable Activity Recognition
Ordóñez, F., & Roggen, D. (2016) · Sensors · doi:10.3390/s16010115 · Cited by 2,761
Research works printed but not linked: 29
- 10.1007/s10072-020-04797-5 · DOI
- 10.1016/s1474-4422(04)00851-8 · DOI
- 10.2340/16501977-1115 · DOI
- 10.1109/icorr.2005.1501072 · DOI
- 10.1016/j.apmr.2018.03.017 · DOI
- 10.1177/1084822316630278 · DOI
- 10.3389/fneur.2017.00284 · DOI
- 10.1016/j.artmed.2019.02.001 · DOI
- 10.1109/TNSRE.2016.2584003 · DOI
- 10.1109/JTEHM.2018.2822681 · DOI
- 10.1186/s12984-019-0569-x · DOI
- 10.3390/s100807772 · DOI · Paper page
- 10.1016/j.apmr.2009.10.025 · DOI · Paper page
- 10.1007/s10586-013-0335-y · DOI
- 10.1177/1545968316680490 · DOI
- 10.1007/s40279-014-0142-5 · DOI
- 10.1109/smc.2015.263 · DOI · Paper page
- 10.1016/j.cmpb.2014.06.020 · DOI
- 10.1186/1743-0003-11-108 · DOI · Paper page
- 10.1089/tmj.2012.0300 · DOI
- 10.1111/ijs.12029 · DOI
- 10.1161/STR.0000000000000098 · DOI · Paper page
- 10.1177/0269215515601177 · DOI
- 10.1152/jn.01295.2006 · DOI
- 10.1080/16501970410023434 · DOI
- 10.1016/s0140-6736(98)03340-6 · DOI
- 10.2196/17216 · DOI · Paper page
- 10.2196/17804 · DOI
- 10.3390/s22031170 · DOI
Metadata
- Authors
- Guo, L., Wang, J., Wu, Q., Li, X., Zhang, B., Zhou, L., & Xiong, D.
- Affiliations
- University of Science and Technology of China (CN)
- Tang Du Hospital (CN)
- Jiangsu Province Hospital (CN)
- Corresponding author
- Xiong, Daxi
- Venue
- JMIR mhealth and uhealth
- Publisher
- JMIR Publications Inc.
- Published
- 2022-06-20
- Volume
- 11
- Pages
- e40416-e40416
- ISSN
- 2291-5222 (ISSN-L)
- OpenAlex
- W4321611486
- Cited by
- 48
- References
- 1
- Citations by year
- 2026: 21 · 2025: 17 · 2024: 7 · 2023: 3
- FWCI
- 5.01
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- JMIR mhealth and uhealth (publishedVersion, cc-by)
- PubMed (publishedVersion)
- PubMed Central (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Telemedicine and Telehealth Implementation
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Medical Practices and Rehabilitation
- Keywords
- stroke rehabilitation, wearable devices, home-based rehabilitation, motor recovery, upper limb motor function, Fugl-Meyer Assessment, physiotherapy, occupational therapy, stroke inpatients, telemedicine, stroke rehabilitation centers, stroke rehabilitation services
- MeSH terms
- Telerehabilitation, Stroke Rehabilitation, Wearable Electronic Devices, Humans, Pilot Projects, Treatment Outcome, Stroke
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical Study of a Wearable Remote Rehabilitation Training System for Patients With Stroke: Randomized Controlled Pilot Trial (Preprint). https://app.cochat.ai/papers/10.2196/preprints.40416
- The paper
- Guo, L., Wang, J., Wu, Q., Li, X., Zhang, B., Zhou, L., & Xiong, D. (2022). Clinical Study of a Wearable Remote Rehabilitation Training System for Patients With Stroke: Randomized Controlled Pilot Trial (Preprint). JMIR mhealth and uhealth. https://doi.org/10.2196/preprints.40416