Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 245

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A Liposomal Nanoscale Contrast Agent for Preclinical CT in Mice

Mukundan, Srinivasan, Ghaghada, Ketan B., Badea, Cristian T., Kao, Chen-Yu, Hedlund, Laurence W., Provenzale, James M., Johnson, G. Allan, Chen, Emmanuel, Bellamkonda, Ravi V., Annapragada, Ananth · 2006 · American Journal of Roentgenology

Abstract

OBJECTIVE: The goal of this study was to determine if an iodinated, liposomal contrast agent could be used for high-resolution, micro-CT of low-contrast, small-size vessels in a murine model. MATERIALS AND METHODS: A second-generation, liposomal blood pool contrast agent encapsulating a high concentration of iodine (83-105 mg I/mL) was evaluated. A total of five mice weighing between 20 and 28 g were infused with equivalent volume doses (500 microL of contrast agent/25 g of mouse weight) and imaged with our micro-CT system for intervals of up to 240 min postinfusion. The animals were anesthetized, mechanically ventilated, and vital signs monitored allowing for simultaneous cardiac and respiratory gating of image acquisition. RESULTS: Initial enhancement of about 900 H in the aorta was obtained, which decreased to a plateau level of approximately 800 H after 2 hr. Excellent contrast discrimination was shown between the myocardium and cardiac blood pool (650-700 H). No significant nephrogram was identified, indicating the absence of renal clearance of the agent. CONCLUSION: The liposomal-based iodinated contrast agent shows long residence time in the blood pool, very high attenuation within submillimeter vessels, and no significant renal clearance rendering it an effective contrast agent for murine vascular imaging using a micro-CT scanner.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.05.0523

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 245

Metadata

Authors
Mukundan, S., Ghaghada, K. B., Badea, C. T., Kao, C.-Y., Hedlund, L. W., Provenzale, J. M., Johnson, G. A., Chen, E., Bellamkonda, R. V., & Annapragada, A.
Venue
American Journal of Roentgenology
Published
2006-02
Volume
186
Issue
2
Pages
300-307
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2135553830
Cited by
245
References
1
FWCI
9.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Liposomal Nanoscale Contrast Agent for Preclinical CT in Mice. https://app.cochat.ai/papers/10.2214/ajr.05.0523
The paper
Mukundan, S., Ghaghada, K. B., Badea, C. T., Kao, C.-Y., Hedlund, L. W., Provenzale, J. M., Johnson, G. A., Chen, E., Bellamkonda, R. V., & Annapragada, A. (2006). A Liposomal Nanoscale Contrast Agent for Preclinical CT in Mice. American Journal of Roentgenology. https://doi.org/10.2214/ajr.05.0523

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.