The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Liposomal Nanoscale Contrast Agent for Preclinical CT in Mice
Abstract
OBJECTIVE: The goal of this study was to determine if an iodinated, liposomal contrast agent could be used for high-resolution, micro-CT of low-contrast, small-size vessels in a murine model. MATERIALS AND METHODS: A second-generation, liposomal blood pool contrast agent encapsulating a high concentration of iodine (83-105 mg I/mL) was evaluated. A total of five mice weighing between 20 and 28 g were infused with equivalent volume doses (500 microL of contrast agent/25 g of mouse weight) and imaged with our micro-CT system for intervals of up to 240 min postinfusion. The animals were anesthetized, mechanically ventilated, and vital signs monitored allowing for simultaneous cardiac and respiratory gating of image acquisition. RESULTS: Initial enhancement of about 900 H in the aorta was obtained, which decreased to a plateau level of approximately 800 H after 2 hr. Excellent contrast discrimination was shown between the myocardium and cardiac blood pool (650-700 H). No significant nephrogram was identified, indicating the absence of renal clearance of the agent. CONCLUSION: The liposomal-based iodinated contrast agent shows long residence time in the blood pool, very high attenuation within submillimeter vessels, and no significant renal clearance rendering it an effective contrast agent for murine vascular imaging using a micro-CT scanner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noninvasive detection of macrophages using a nanoparticulate contrast agent for computed tomography
Hyafil, F., Cornily, J.-C., Feig, J. E., Gordon, R., Vucic, E., Amirbekian, V., Fisher, E. A., Fuster, V., Feldman, L. J., & Fayad, Z. A. (2007) · Nature Medicine · doi:10.1038/nm1571 · Cited by 467
Cited by
Guidelines for assessment of bone microstructure in rodents using micro–computed tomography
Bouxsein, M. L., Boyd, S. K., Christiansen, B. A., Guldberg, R. E., Jepsen, K. J., & Müller, R. (2010) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.141 · Cited by 4,433
Imaging and drug delivery using theranostic nanoparticles
Janib, S. M., Moses, A. S., & MacKay, J. A. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.08.004 · Cited by 1,248
X-ray-Computed Tomography Contrast Agents
Lusic, H., & Grinstaff, M. W. (2013) · Chemical Reviews · doi:10.1021/cr200358s · Cited by 1,108
Lee, N., Choi, S. H., & Hyeon, T. (2013) · Advanced Materials · doi:10.1002/adma.201300081 · Cited by 657
Noninvasive detection of macrophages using a nanoparticulate contrast agent for computed tomography
Hyafil, F., Cornily, J.-C., Feig, J. E., Gordon, R., Vucic, E., Amirbekian, V., Fisher, E. A., Fuster, V., Feldman, L. J., & Fayad, Z. A. (2007) · Nature Medicine · doi:10.1038/nm1571 · Cited by 467
Metadata
- Authors
- Mukundan, S., Ghaghada, K. B., Badea, C. T., Kao, C.-Y., Hedlund, L. W., Provenzale, J. M., Johnson, G. A., Chen, E., Bellamkonda, R. V., & Annapragada, A.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2006-02
- Volume
- 186
- Issue
- 2
- Pages
- 300-307
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2135553830
- Cited by
- 245
- References
- 1
- FWCI
- 9.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Liposomal Nanoscale Contrast Agent for Preclinical CT in Mice. https://app.cochat.ai/papers/10.2214/ajr.05.0523
- The paper
- Mukundan, S., Ghaghada, K. B., Badea, C. T., Kao, C.-Y., Hedlund, L. W., Provenzale, J. M., Johnson, G. A., Chen, E., Bellamkonda, R. V., & Annapragada, A. (2006). A Liposomal Nanoscale Contrast Agent for Preclinical CT in Mice. American Journal of Roentgenology. https://doi.org/10.2214/ajr.05.0523
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.