Testing the Effect of Computer-Assisted Detection on Interpretive Performance in Screening Mammography
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The objective of our study was to test whether the use of computer-assisted detection (CAD) improves sensitivity at no cost to specificity for the detection of breast cancer and enables more accurate assessment of fatty breast tissue compared with dense breast tissue. MATERIALS AND METHODS: We created a stratified random sample of screening mammograms weighted with difficult cases split evenly among women with fatty breast tissue and those with dense breast tissue: 114 patients were cancer-free, 114 had cancer 1 year after screening, and 113 had cancer 13-24 months after screening. In test settings 6 months apart, 19 community radiologists interpreted 341 bilateral screening mammograms with and without CAD. We compared the sensitivity and specificity using regression models adjusting for repeated measures. RESULTS: CAD assistance did not affect overall sensitivity (cancer by 1 year: 63.2% without CAD and 62.0% with CAD; cancer in 13-24 months: 33.5% without CAD and 32.3% with CAD), but its effect differed for visible masses that were marked by CAD compared with those that were not marked by CAD (hereafter referred to as "unmarked"). CAD was associated with improved sensitivity for marked visible cancers and decreased sensitivity for unmarked visible masses; the sensitivities without and with CAD, respectively, were as follows: marked cancer by 1 year, 82.7% versus 83.1%; marked cancer in 13-24 months, 44.2% versus 57.9%; unmarked cancer by 1 year, 37.4% versus 30.1%; unmarked cancer in 13-24 months, 29.7% versus 23.0% (p < 0.03 for both interactions between assistance and CAD marking for cancer by 1 year and cancer in 13-24 months). CAD marked 77% (70/91) of the visible cancers by 1 year and 67.3% (37/55) of the visible cancers in 13-24 months. CAD marked more visible calcified lesions (86%) than masses and asymmetric densities (67%) (p < 0.05). Overall specificity was 72% without and 75% with CAD (p < 0.02). CAD had a greater effect on both specificity (p < 0.02) and sensitivity (p < 0.03) among radiologists who interpret more than 50 mammograms per week. The results were the same for fatty breast tissue and dense breast tissue. CONCLUSION: In this experiment, CAD increased interpretive specificity but did not affect sensitivity because visible noncalcified lesions that went unmarked by CAD were less likely to be assessed as abnormal by radiologists. Breast density did not affect CAD's performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Covariance Estimator for GEE with Improved Small‐Sample Properties
Mancl, L. A., & DeRouen, T. A. (2001) · Biometrics · doi:10.1111/j.0006-341x.2001.00126.x · Cited by 656
Cited by
Diagnostic Accuracy of Digital Screening Mammography With and Without Computer-Aided Detection
Lehman, C. D., Wellman, R. D., Buist, D. S. M., Kerlikowske, K., Tosteson, A. N. A., & Miglioretti, D. L. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.5231 · Cited by 678
Self-citationInfluence of Computer-Aided Detection on Performance of Screening Mammography
Fenton, J. J., Taplin, S. H., Carney, P. A., Abraham, L., Sickles, E. A., D'Orsi, C., Berns, E. A., Cutter, G., Hendrick, R. E., Barlow, W. E., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa066099 · Cited by 619
Self-citationEffectiveness of Computer-Aided Detection in Community Mammography Practice
Fenton, J. J., Abraham, L., Taplin, S. H., Geller, B. M., Carney, P. A., D'Orsi, C., Elmore, J. G., Barlow, W. E., & for the Breast Cancer Surveillance Consortium (2011) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djr206 · Cited by 168
Self-citationKohli, A., & Jha, S. (2018) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2017.12.029 · Cited by 114
“The only issue was its cost-effectiveness [5-7].”
Evaluating Imaging and Computer-aided Detection and Diagnosis Devices at the FDA
Gallas, B. D., Chan, H.-P., D’Orsi, C. J., Dodd, L. E., Giger, M. L., Gur, D., Krupinski, E. A., Metz, C. E., Myers, K. J., Obuchowski, N. A., et al. (2012) · Academic Radiology · doi:10.1016/j.acra.2011.12.016 · Cited by 81
“Because these demands are so high, advanced clinical-use studies might also take the form of meta-analyses (37–39).”
Background
Metadata
- Authors
- Taplin, S. H., Rutter, C. M., & Lehman, C. D.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2006-12
- Volume
- 187
- Issue
- 6
- Pages
- 1475-1482
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2063838177
- Cited by
- 52
- References
- 1
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.