CoChat
Cited by 332

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Cortical Morphologic Features of Axillary Lymph Nodes as a Predictor of Metastasis in Breast Cancer: In Vitro Sonographic Study

Bedi, Deepak G., Krishnamurthy, Rajesh, Krishnamurthy, Savitri, Edeiken, Beth S., Le-Petross, Huong, Fornage, Bruno D., Bassett, Roland L., Hunt, Kelly K. · 2008 · American Journal of Roentgenology

Abstract

OBJECTIVE: The purpose of this study was in vitro sonographic-pathologic correlation of findings in dissected axillary lymph nodes from breast cancer patients undergoing axillary lymph node dissection and classification of the sonographic appearance of the nodes on the basis of cortical morphologic features to facilitate early recognition of metastatic disease. MATERIALS AND METHODS: High-resolution sonography was used for in vitro examination of 171 lymph nodes from 19 axillae in 18 patients with unknown nodal status who underwent axillary lymph node dissection for early infiltrating breast cancer. The images were evaluated by two blinded observers, and discordant readings were referred to a third blinded observer. Each lymph node was classified as one of types 1-6 according to cortical morphologic features. Types 1-4 were considered benign, ranging from hyperechoic with no visible cortex to thickened generalized hypoechoic cortical lobulation. Type 5 (focal hypoechoic cortical lobulation) and type 6 (hypoechoic node with absent hilum) nodes were considered metastatic. The reference standard for metastatic disease was histopathologic evaluation of sectioned nodes by a single pathologist blinded to sonographic findings. Largest nodal diameter also was measured. RESULTS: Interobserver agreement was 77% for classification of nodal morphology (types 1-6) and 88% for characterization of a node as benign or malignant. Sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy of cortical shape in prediction of metastatic involvement of axillary nodes were 77%, 80%, 36%, 96%, and 80%. Type 4 nodes had the most false-negative findings (four of 36). Node size ranged from 0.2 to 3.8 cm, and subcentimeter nodes of all types were detected. CONCLUSION: In breast cancer, axillary lymph nodes can be classified according to cortical morphologic features. Predominantly hyperechoic nodes (types 1-3) can be considered benign. Generalized cortical lobulation (type 4) is uncommonly a false-negative finding, but metastasis, if present, is invariably detected at sentinel node mapping. The presence of asymmetric focal hypoechoic cortical lobulation (type 5) or a completely hypoechoic node (type 6) should serve as a guideline for universal performance of fine-needle aspiration for preoperative staging of breast cancer. This classification, when verified with larger samples, may serve as a useful clinical guideline if proven with results of in vivo studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.07.2460

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Bedi, D. G., Krishnamurthy, R., Krishnamurthy, S., Edeiken, B. S., Le-Petross, H., Fornage, B. D., Bassett, R. L., & Hunt, K. K.
Venue
American Journal of Roentgenology
Published
2008-09
Volume
191
Issue
3
Pages
646-652
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2114032724
Cited by
332
References
4
FWCI
6.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.