Usefulness of Computer-Aided Diagnosis Schemes for Vertebral Fractures and Lung Nodules on Chest Radiographs
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: We retrospectively evaluated the usefulness of computer-aided diagnosis (CAD) schemes to radiologist performance in the simultaneous detection of vertebral fractures and lung nodules on chest radiographs. MATERIALS AND METHODS: We evaluated posteroanterior and lateral chest images of 21 patients with vertebral fractures, 31 patients with lung nodules, and 10 persons acting as controls. The total number of subjects was 60 because both lesions were present in four patients. Eighteen radiologists were asked to detect vertebral fractures and nodules simultaneously on posteroanterior and lateral images. The radiologists indicated their confidence level ratings regarding the presence or absence of lesions and the most likely location of each lesion on either posteroanterior or lateral images, first without and then with CAD output. The observers' performance was evaluated with use of receiver operating characteristic (ROC) and jackknife free-response ROC curves. RESULTS: With the CAD scheme, the average area under the ROC curve for detection of vertebral fractures improved from 0.906 to 0.951 (p = 0.002). That for lung nodules also improved, but the improvement was not statistically significant (0.804-0.816, p = 0.297). The figure-of-merit values obtained with the jackknife free-response ROC program improved from 0.585 to 0.680 (p < 0.001) for vertebral fractures and from 0.622 to 0.650 (p = 0.017) for nodules, both results having statistical significance. Average sensitivity in the detection of lesions improved from 59.8% to 69.3% for vertebral fractures and from 64.9% to 67.6% for nodules. CONCLUSION: In the detection of vertebral fractures and lung nodules on chest images, diagnostic accuracy among radiologists improves with the use of CAD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chesnut, C. H., Silverman, S., Andriano, K., Genant, H., Gimona, A., Harris, S., Kiel, D., LeBoff, M., Maricic, M., Miller, P., et al. (2000) · The American Journal of Medicine · doi:10.1016/s0002-9343(00)00490-3 · Cited by 1,122
Cited by
Deep learning predicts hip fracture using confounding patient and healthcare variables
Badgeley, M. A., Zech, J. R., Oakden-Rayner, L., Glicksberg, B. S., Liu, M., Gale, W., McConnell, M. V., Percha, B., Snyder, T. M., & Dudley, J. T. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0105-1 · Cited by 290
Improving the radiologist-CAD interaction: designing for appropriate trust
Jorritsma, W., Cnossen, F., & van Ooijen, P. M. A. (2015) · Clinical Radiology · doi:10.1016/j.crad.2014.09.017 · Cited by 61
Lee, K. H., Goo, J. M., Park, C. M., Lee, H. J., & Jin, K. N. (2012) · Korean Journal of Radiology · doi:10.3348/kjr.2012.13.5.564 · Cited by 37
Li, D., Pehrson, L. M., Lauridsen, C. A., Tøttrup, L., Fraccaro, M., Elliott, D., Zając, H. D., Darkner, S., Carlsen, J. F., & Nielsen, M. B. (2021) · Diagnostics · doi:10.3390/diagnostics11122206 · Cited by 35
Metadata
- Authors
- Kasai, S., Li, F., Shiraishi, J., & Doi, K.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2008-07
- Volume
- 191
- Issue
- 1
- Pages
- 260-265
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2152489810
- Cited by
- 30
- References
- 1
- FWCI
- 1.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.