The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Diagnostic Performance of Low-Dose CT for the Detection of Urolithiasis: A Meta-Analysis
Abstract
OBJECTIVE: The objective of our study was to perform a meta-analysis to evaluate the diagnostic performance of low-dose CT for the diagnosis of urolithiasis (seven studies, 1,061 patients). MATERIALS AND METHODS: The medical literature from 1995 to 2007 was searched using PubMed, Medline, and Cochrane Library databases for articles on studies that used low-dose CT (< 3 mSv dose applied for the entire CT examination) as a diagnostic test for the detection of urolithiasis. Prospective and retrospective studies were included if they separately reported the rate of true-positive, true-negative, false-positive, and false-negative diagnoses of urolithiasis from low-dose CT compared with the positive and negative rates of normal-dose CT or a combination of diagnostic tests. Two readers assessed the quality of the studies. RESULTS: The pooled sensitivity and specificity of low-dose CT for the diagnosis of urolithiasis were 0.966 (95% CI, 0.950-0.978) and 0.949 (95% CI, 0.920-0.970), respectively. CONCLUSION: The results of this meta-analysis suggest that a low-dose CT protocol can be used as the initial imaging technique in the workup of patients with suspected urolithiasis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Practical Statistics for Medical Research.
Walter, S. D., & Altman, D. G. (1992) · Biometrics · doi:10.2307/2532320 · Cited by 11,668
Practical Statistics for Medical Research
Altman, D. G. (1990) · doi:10.1201/9780429258589 · Cited by 10,668
Moher, D., Cook, D. J., Eastwood, S., Olkin, I., Rennie, D., & Stroup, D. F. (1999) · The Lancet · doi:10.1016/s0140-6736(99)04149-5 · Cited by 4,826
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Meta-DiSc: a software for meta-analysis of test accuracy data
Zamora, J., Abraira, V., Muriel, A., Khan, K., & Coomarasamy, A. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-31 · Cited by 1,883
Moses, L. E., Shapiro, D., & Littenberg, B. (1993) · Statistics in Medicine · doi:10.1002/sim.4780121403 · Cited by 1,405
Kidney stones: pathophysiology and medical management
Moe, O. W. (2006) · The Lancet · doi:10.1016/s0140-6736(06)68071-9 · Cited by 1,052
Iterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility Study
Hara, A. K., Paden, R. G., Silva, A. C., Kujak, J. L., Lawder, H. J., & Pavlicek, W. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.2397 · Cited by 732
Cited by
An overview of kidney stone imaging techniques
Brisbane, W., Bailey, M. R., & Sorensen, M. D. (2016) · Nature Reviews Urology · doi:10.1038/nrurol.2016.154 · Cited by 391
Low-Dose Versus Standard-Dose CT Protocol in Patients with Clinically Suspected Renal Colic
Poletti, P.-A., Platon, A., Rutschmann, O. T., Schmidlin, F. R., Iselin, C. E., & Becker, C. D. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.0793 · Cited by 371
Moore, C. L., Bomann, S., Daniels, B., Luty, S., Molinaro, A., Singh, D., & Gross, C. P. (2014) · BMJ · doi:10.1136/bmj.g2191 · Cited by 157
Metadata
- Authors
- Niemann, T., Kollmann, T., & Bongartz, G.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2008-08
- Volume
- 191
- Issue
- 2
- Pages
- 396-401
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2130363618
- Cited by
- 296
- References
- 23
- FWCI
- 0.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic Performance of Low-Dose CT for the Detection of Urolithiasis: A Meta-Analysis. https://app.cochat.ai/papers/10.2214/ajr.07.3414
- The paper
- Niemann, T., Kollmann, T., & Bongartz, G. (2008). Diagnostic Performance of Low-Dose CT for the Detection of Urolithiasis: A Meta-Analysis. American Journal of Roentgenology. https://doi.org/10.2214/ajr.07.3414
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.