Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 198

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Feasibility of In Vivo MR Elastographic Splenic Stiffness Measurements in the Assessment of Portal Hypertension

Open access
Talwalkar, Jayant A., Yin, Meng, Venkatesh, Sudhakar, Rossman, Phillip J., Grimm, Roger C., Manduca, Armando, Romano, Anthony, Kamath, Patrick S., Ehman, Richard L.·2009·American Journal of Roentgenology

Abstract

OBJECTIVE: Liver stiffness is associated with portal hypertension in patients with chronic liver disease. However, the relation between spleen stiffness and clinically significant portal hypertension remains unknown. The purposes of this study were to determine the feasibility of measuring spleen stiffness with MR elastography and to prospectively test the technique in healthy volunteers and in patients with compensated liver disease. MATERIALS AND METHODS: Spleen stiffness was measured with MR elastography in 12 healthy volunteers (mean age, 37 years; range, 25-82 years) and 38 patients (mean age, 56 years; range, 36-60 years) with chronic liver disease of various causes. For patients with liver disease, laboratory findings, spleen size, presence and size of esophageal varices, and liver histologic results were recorded. Statistical analyses were performed to assess all measurements. RESULTS: MR elastography of the spleen was successfully performed on all volunteers and patients. The mean spleen stiffness was significantly lower in the volunteers (mean, 3.6 +/- 0.3 kPa) than in the patients with liver fibrosis (mean, 5.6 +/- 5.0 kPa; range, 2.7-19.2 kPa; p < 0.001). In addition, a significant correlation was observed between liver stiffness and spleen stiffness for the entire cohort (r(2) = 0.75; p < 0.001). Predictors of spleen stiffness were splenomegaly, spleen volume, and platelet count. A mean spleen stiffness of 10.5 kPa or greater was identified in all patients with esophageal varices. CONCLUSION: MR elastography of the spleen is feasible and shows promise as a quantitative method for predicting the presence of esophageal varices in patients with advanced hepatic fibrosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.07.3504

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 198

Metadata

Authors
Talwalkar, J. A., Yin, M., Venkatesh, S., Rossman, P. J., Grimm, R. C., Manduca, A., Romano, A., Kamath, P. S., & Ehman, R. L.
Venue
American Journal of Roentgenology
Published
2009-07
Volume
193
Issue
1
Pages
122-127
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W1989245785
Cited by
198
References
1
FWCI
11.74
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Feasibility of In Vivo MR Elastographic Splenic Stiffness Measurements in the Assessment of Portal Hypertension. https://app.cochat.ai/papers/10.2214/ajr.07.3504
The paper
Talwalkar, J. A., Yin, M., Venkatesh, S., Rossman, P. J., Grimm, R. C., Manduca, A., Romano, A., Kamath, P. S., & Ehman, R. L. (2009). Feasibility of In Vivo MR Elastographic Splenic Stiffness Measurements in the Assessment of Portal Hypertension. American Journal of Roentgenology. https://doi.org/10.2214/ajr.07.3504

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.