Respiratory-Triggered Versus Breath-Hold Diffusion-Weighted MRI of Liver Lesions: Comparison of Image Quality and Apparent Diffusion Coefficient Values
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The purpose of our study was to compare respiratory-triggered and breath-hold diffusion-weighted liver MRI and to assess the agreement in the apparent diffusion co-efficient (ADC) values between the two sequences. MATERIALS AND METHODS: Forty-eight patients (27 men, 21 women; mean age, 45.2 years) with focal liver lesions underwent respiratory-triggered and breath-hold diffusion-weighted MRI (DWI) in addition to routine MRI. Both sequences had identical imaging parameters except for signal averages, which were 6 in respiratory-triggered and 2 in breath-hold sequences. A total of 92 lesions (maximum of three lesions per patient; 37 benign, 55 malignant) were evaluated. Lesions were confirmed by typical imaging appearance, histopathology, or follow-up. Signal-to-noise ratio (SNR) of the liver, contrast-to-noise ratio (CNR), and relative contrast ratio of the lesions were measured in each DWI sequence and were statistically compared using the Mann-Whitney U test. The ADC values of normal liver and each category of liver lesions in the two sequences were compared for agreement using Pearson's coefficient and reliability analysis scale. RESULTS: The SNR of the normal liver was significantly better on respiratory-triggered DWI than on breath-hold DWI. The mean CNR of metastases, hepatocellular carcinomas, and abscesses was significantly better in the respiratory-triggered DWI than in the breath-hold DWI sequences. The ADC values of liver and focal lesions measured by the two techniques showed good agreement. The SDs of the ADC values of normal liver were similar in the two sequences. CONCLUSION: Respiratory-triggered DWI should be preferred over breath-hold DWI for the evaluation of focal liver lesions because it provides better image quality and SNR without any compromise in the calculated ADC values.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diffusion-Weighted MRI in the Body: Applications and Challenges in Oncology
Koh, D.-M., & Collins, D. J. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1403 · Cited by 1,993 · cited 2×
“Various studies have reported satisfactory image quality at this b value [17, 18], and the calculated ADC is relatively free of perfusion contamination that predominates at low b values [19].”
BackgroundTakahara, T., Imai, Y., Yamashita, T., Yasuda, S., Nasu, S., & CAUTEREN, M. V. (2004) · PubMed · Cited by 781
Taouli, B., Vilgrain, V., Dumont, E., Daire, J.-L., Fan, B., & Menu, Y. (2003) · Radiology · doi:10.1148/radiol.2261011904 · Cited by 577 · cited 2×
“Chemical shift selective fat suppression was preferred over an inversion-recovery fat-suppression technique because of its better SNR [4].”
BackgroundMethodYamada, I., Aung, W., Himeno, Y., Nakagawa, T., & Shibuya, H. (1999) · Radiology · doi:10.1148/radiology.210.3.r99fe17617 · Cited by 519 · cited 1×
“Several publications have endorsed its usefulness for the detection and characterization of focal hepatic lesions [2–13], for assessing treatment response [14–16], and for the evaluation of diffuse liver diseases [17].”
BackgroundDiffusion-weighted single-shot echoplanar MR imaging for liver disease.
Kim, T., Murakami, T., Takahashi, S., Hori, M., Tsuda, K., & Nakamura, H. (1999) · American Journal of Roentgenology · doi:10.2214/ajr.173.2.10430143 · Cited by 349
Koh, D.-M., Scurr, E., Collins, D., Kanber, B., Norman, A., Leach, M. O., & Husband, J. E. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.0601 · Cited by 344
Hepatic Metastases: Diffusion-weighted Sensitivity-encoding versus SPIO-enhanced MR Imaging
Nasu, K., Kuroki, Y., Nawano, S., Kuroki, S., Tsukamoto, T., Yamamoto, S., Motoori, K., & Ueda, T. (2006) · Radiology · doi:10.1148/radiol.2383041384 · Cited by 322 · cited 2×
“However, it has been suggested that multiple averages also increase the probability of data acquisition in the diastolic phase and thus minimize cardiac motion-related signal loss, especially in the left lobe of the liver [9].”
BackgroundADC Measurement of Abdominal Organs and Lesions Using Parallel Imaging Technique
Yoshikawa, T., Kawamitsu, H., Mitchell, D. G., Ohno, Y., Ku, Y., Seo, Y., Fujii, M., & Sugimura, K. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.05.0778 · Cited by 300 · cited 2×
“Various studies have reported satisfactory image quality at this b value [17, 18], and the calculated ADC is relatively free of perfusion contamination that predominates at low b values [19].”
BackgroundAbdominal diffusion mapping with use of a whole-body echo-planar system.
Müller, M. F., Prasad, P., Siewert, B., Nissenbaum, M. A., Raptopoulos, V, & Edelman, R. R. (1994) · Radiology · doi:10.1148/radiology.190.2.8284402 · Cited by 245 · cited 1×
“© American Roentgen Ray Society D iffusion-weighted MRI (DWI) of the abdomen has seen significant improvements since the earliest reports more than two decades ago [1].”
BackgroundPractical Aspects of Assessing Tumors Using Clinical Diffusion-weighted Imaging in the Body
KOH, D.-M., TAKAHARA, T., IMAI, Y., & COLLINS, D. J. (2007) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.6.211 · Cited by 211 · cited 1×
“Breath-hold DWI is also theoretically better than non–breath-hold techniques in quantifying the ADC of smaller lesions because it is less likely to be degraded by respiratory motion–related partial volume averaging artifacts [26].”
Background
Cited by
Clinical intravoxel incoherent motion and diffusion MR imaging: Past, present, and future
Iima, M., & Le Bihan, D. (2016) · Radiology · doi:10.1148/radiol.2015150244 · Cited by 498
Value of Diffusion-Weighted MRI for Assessing Liver Fibrosis and Cirrhosis
Sandrasegaran, K., Akisik, F. M., Lin, C., Tahir, B., Rajan, J., Saxena, R., & Aisen, A. M. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.2436 · Cited by 192
Dyvorne, H. A., Galea, N., Nevers, T., Fiel, M. I., Carpenter, D., Wong, E., Orton, M., de Oliveira, A., Feiweier, T., Vachon, M.-L., et al. (2013) · Radiology · doi:10.1148/radiol.12120686 · Cited by 182
Metadata
- Authors
- Kandpal, H., Sharma, R., Madhusudhan, K. S., & Kapoor, K. S.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2009-04
- Volume
- 192
- Issue
- 4
- Pages
- 915-922
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1986264356
- Cited by
- 198
- References
- 23
- FWCI
- 12.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.