The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Quantitative Diffusion-Weighted Imaging as an Adjunct to Conventional Breast MRI for Improved Positive Predictive Value
Abstract
OBJECTIVE: The purpose of our study was to investigate whether adding diffusion-weighted imaging (DWI) to dynamic contrast-enhanced MRI (DCE-MRI) could improve the positive predictive value (PPV) of breast MRI. MATERIALS AND METHODS: The retrospective study included 70 women with 83 suspicious breast lesions on DCE-MRI (BI-RADS 4 or 5) who underwent subsequent biopsy. DWI was acquired during clinical breast MRI using b = 0 and 600 s/mm(2). Apparent diffusion coefficient (ADC) values were compared for benign and malignant lesions. PPV was calculated for DCE-MRI alone (based on biopsy recommendations) and DCE-MRI plus DWI (adding an ADC threshold) for the same set of lesions. Results were further compared by lesion type (mass, nonmasslike enhancement) and size. RESULTS: Of the 83 suspicious lesions, 52 were benign and 31 were malignant (11 ductal carcinoma in situ [DCIS], 20 invasive carcinoma). Both DCIS (mean ADC, 1.31 +/- 0.24 x 10(-3) mm(2)/s) and invasive carcinoma (mean ADC, 1.29 +/- 0.29 x 10(-3) mm(2)/s) exhibited lower mean ADC than benign lesions (1.70 +/- 0.44 x 10(-3) mm(2)/s, p < 0.001). Applying an ADC threshold of 1.81 x 10(-3) mm(2)/s for 100% sensitivity produced a PPV of 47% versus 37% for DCE-MRI alone, which would have avoided biopsy for 33% (17/52) of benign lesions without missing any cancers. DWI increased PPV similarly for masses and nonmasslike enhancement and preferentially improved PPV for smaller (< or = 1 cm) versus larger lesions. CONCLUSION: DWI shows potential for improving the PPV of breast MRI for lesions of varied types and sizes. However, considerable overlap in ADC of benign and malignant lesions necessitates validation of these findings in larger studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
American Cancer Society Guidelines for Breast Screening with MRI as an Adjunct to Mammography
Saslow, D., Boetes, C., Burke, W., Harms, S., Leach, M. O., Lehman, C. D., Morris, E., Pisano, E., Schnall, M., Sener, S., et al. (2007) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.57.2.75 · Cited by 2,637
Self-citationBreast imaging reporting and data system (BI-RADS)
Liberman, L., & Menell, J. H. (2002) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(01)00017-3 · Cited by 2,155
Kriege, M., Brekelmans, C. T. M., Boetes, C., Besnard, P. E., Zonderland, H. M., Obdeijn, I. M., Manoliu, R. A., Kok, T., Peterse, H., Tilanus-Linthorst, M. M. A., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa031759 · Cited by 1,687
Berg, W. A., Gutierrez, L., NessAiver, M. S., Carter, W. B., Bhargavan, M., Lewis, R. S., & Ioffe, O. B. (2004) · Radiology · doi:10.1148/radiol.2333031484 · Cited by 1,439
Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
Jones, D. K., Horsfield, M. A., & Simmons, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.0.co;2-q · Cited by 1,403
Sugahara, T., Korogi, Y., Kochi, M., Ikushima, I., Shigematu, Y., Hirai, T., Okuda, T., Liang, L., Ge, Y., Komohara, Y., et al. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199901)9:1<53::aid-jmri7>3.0.co;2-2 · Cited by 1,163
Elmore, J. G. (2005) · JAMA · doi:10.1001/jama.293.10.1245 · Cited by 1,075
MRI Evaluation of the Contralateral Breast in Women with Recently Diagnosed Breast Cancer
Lehman, C. D., Gatsonis, C., Kuhl, C. K., Hendrick, R. E., Pisano, E. D., Hanna, L., Peacock, S., Smazal, S. F., Maki, D. D., Julian, T. B., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa065447 · Cited by 945
Self-citationHoussami, N., Ciatto, S., Macaskill, P., Lord, S. J., Warren, R. M., Dixon, J. M., & Irwig, L. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.15.2108 · Cited by 831
Cited by
On behalf of the EUSOBI international Breast Diffusion-Weighted Imaging working group, Baltzer, P., Mann, R. M., Iima, M., Sigmund, E. E., Clauser, P., Gilbert, F. J., Martincich, L., Partridge, S. C., Patterson, A., et al. (2020) · European Radiology · doi:10.1007/s00330-019-06510-3 · Cited by 437
Self-citationDiffusion-weighted breast MRI: Clinical applications and emerging techniques
Partridge, S. C., Nissan, N., Rahbar, H., Kitsch, A. E., & Sigmund, E. E. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25479 · Cited by 340
Self-citationDalmiş, M. U., Gubern-Mérida, A., Vreemann, S., Bult, P., Karssemeijer, N., Mann, R., & Teuwen, J. (2019) · Investigative Radiology · doi:10.1097/rli.0000000000000544 · Cited by 120
Metadata
- Authors
- Partridge, S. C., DeMartini, W. B., Kurland, B. F., Eby, P. R., White, S. W., & Lehman, C. D.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2009-12
- Volume
- 193
- Issue
- 6
- Pages
- 1716-1722
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2128609253
- Cited by
- 269
- References
- 28
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.