The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
In Defense of Body CT
Open accessAbstract
OBJECTIVE: Rapid technical developments and an expanding list of applications that have supplanted less accurate or more invasive diagnostic tests have led to a dramatic increase in the use of body CT in medical practice since its introduction in 1975. Our purpose here is to discuss medical justification of the small potential risk associated with the ionizing radiation used in CT and to provide perspectives on practice-specific decisions that can maximize overall patient benefit. In addition, we review available dose management and optimization techniques. CONCLUSION: Dose reduction strategies described in this article must be well understood and properly used, but also require broad-based practice strategies that extend beyond the CT scanner console and default, generic manufacturer settings. In the final analysis, physicians must request the imaging examination that best addresses the specific medical question without allowing worries about radiation to dissuade them or their patients from obtaining needed CT examinations. Ongoing efforts to ensure that CT examinations are both medically justified and optimally performed must continue, and education must be provided to the medical community and general public that put both the potential risks--and benefits--of CT examinations into proper perspective.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222 · cited 1×
“However, in spite of measurable health benefits, considerable media attention has been given to the very small potential health risk associated with the ionizing radiation from a CT exam [1-3].”
BackgroundStrategies for Reducing Radiation Dose in CT
McCollough, C. H., Primak, A. N., Braun, N., Kofler, J., Yu, L., & Christner, J. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2008.10.006 · Cited by 842
Self-citation
Cited by
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 395
Self-citationAge-Related Changes in Trabecular and Cortical Bone Microstructure
Chen, H., Zhou, X., Fujita, H., Onozuka, M., & Kubo, K.-Y. (2013) · International Journal of Endocrinology · doi:10.1155/2013/213234 · Cited by 305
Metadata
- Authors
- McCollough, C. H., Guimarães, L., & Fletcher, J. G.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2009-07
- Volume
- 193
- Issue
- 1
- Pages
- 28-39
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2115570802
- Cited by
- 165
- References
- 2
- FWCI
- 12.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In Defense of Body CT. https://app.cochat.ai/papers/10.2214/ajr.09.2754
- The paper
- McCollough, C. H., Guimarães, L., & Fletcher, J. G. (2009). In Defense of Body CT. American Journal of Roentgenology. https://doi.org/10.2214/ajr.09.2754
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.