CoChat

Comparison of Ultrasound and CT in the Evaluation of Pneumonia Complicated by Parapneumonic Effusion in Children

Kurian, Jessica, Levin, Terry L., Han, Bokyung K., Taragin, Benjamin H., Weinstein, Samuel · 2009 · American Journal of Roentgenology
Cited by 164

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The purpose of our study was to compare chest ultrasound and chest CT in children with complicated pneumonia and parapneumonic effusion. MATERIALS AND METHODS: We retrospectively compared chest ultrasound and chest CT in 19 children (nine girls and 10 boys; age range, 8 months-17 years) admitted with complicated pneumonia and parapneumonic effusion between December 2006 and January 2009. Images were evaluated for effusion, loculation, fibrin strands, parenchymal consolidation, necrosis, and abscess. In the subset of patients who underwent surgical management, imaging findings were correlated with operative findings. RESULTS: Eighteen of 19 patients had an effusion on both chest ultrasound and chest CT. The findings of effusion loculation as well as parenchymal consolidation and necrosis or abscess were similar between the two techniques. Chest ultrasound was better able to visualize fibrin strands within the effusions. Of the 14 patients who underwent video-assisted thoracoscopy, five had surgically proven parenchymal abscess or necrosis. Preoperatively, chest ultrasound was able to show parenchymal abscess or necrosis in four patients, whereas chest CT was able to show parenchymal abscess or necrosis in three. CONCLUSION: In our series, chest ultrasound and chest CT were similar in their ability to detect loculated effusion and lung necrosis or abscess resulting from complicated pneumonia. Chest CT did not provide any additional clinically useful information that was not also seen on chest ultrasound. We suggest that the imaging workup of complicated pediatric pneumonia include chest radiography and chest ultrasound, reserving chest CT for cases in which the chest ultrasound is technically limited or discrepant with the clinical findings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.09.2791

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Kurian, J., Levin, T. L., Han, B. K., Taragin, B. H., & Weinstein, S.
Venue
American Journal of Roentgenology
Published
2009-12
Volume
193
Issue
6
Pages
1648-1654
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2142083143
Cited by
164
References
5
FWCI
3.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.