New MRI Grading System for the Cervical Canal Stenosis
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The purpose of this study was to propose a new MRI grading system for cervical canal stenosis and to evaluate the reproducibility of the system. MATERIALS AND METHODS: Cervical canal stenosis was classified according to the T2-weighted sagittal images into the following grades: grade 0, absence of canal stenosis; grade 1, subarachnoid space obliteration exceeding 50%; grade 2, spinal cord deformity; and grade 3, spinal cord signal change. The MRI scans of 82 patients (37 men and 45 women; mean age, 65.2 years; range, 60-86 years) were independently analyzed by six radiologists. Interobserver and intraobserver agreements were analyzed using intraclass correlation coefficient (ICC), along with the percentage agreement and kappa statistics. RESULTS: The ICC for interobserver agreement was 0.716-0.802, indicating good-to-excellent agreement. For the distinction among the four grades, the percentage of agreement was 63-64% (κ = 0.60-0.62). The percentage of agreement for the presence of cervical canal stenosis (grade 0 vs grades 1, 2, and 3) was 79-85% (κ = 0.51-0.59). The percentage of agreement for insignificant (grade 0-1) or significant (grade 2-3) stenosis was 81-85% (κ = 0.57-0.66). The percentage of agreement for the presence of spinal cord signal change (grade 0-2 vs grade 3) was 92-95% (κ = 0.70-0.73). The overall intraobserver agreement was excellent, as determined by an ICC of 0.768. CONCLUSION: The new grading system provides a reliable assessment of cervical canal stenosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The kappa statistic in reliability studies: use, interpretation, and sample size requirements
Sim, J., & Wright, C. C. (2005) · Physical Therapy · doi:10.1093/ptj/85.3.257 · Cited by 4,093 · cited 1×
“As for the distinction among the four individual grades, agreement was measured using the linear weighted Cohen kappa statistic, giving greater weight to a difference of more than one step between observers than to a difference of only one step [17].”
MethodJones, J. G. A., Cen, S. Y., Lebel, R. M., Hsieh, P. C., & Law, M. (2013) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3199 · Cited by 157
Harrop, J. S., Naroji, S., Maltenfort, M., Anderson, D. G., Albert, T., Ratliff, J. K., Ponnappan, R. K., Rihn, J. A., Smith, H. E., Hilibrand, A., et al. (2010) · Spine · doi:10.1097/brs.0b013e3181b723af · Cited by 130
Cited by
Nouri, A., Martin, A. R., Mikulis, D., & Fehlings, M. G. (2016) · Neurosurgical Focus · doi:10.3171/2016.3.focus1667 · Cited by 218
“Spinal cord compression can be described based on ap - pearance 40,71,101,111,113 or by measuring the number of com - pression sites, 131 a ratio between the anteroposterior diam - eter at the compressed site and that of a noncompressed site, 26,84 a ratio between the anteroposterior diameter and…”
BackgroundJones, J. G. A., Cen, S. Y., Lebel, R. M., Hsieh, P. C., & Law, M. (2013) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3199 · Cited by 157
“axial or sagittal images of the cervical spinal cord denoted a positive finding, whereas lack of high SI was considered negative.(25,26)”
Background
Metadata
- Authors
- Kang, Y., Lee, J. W., Koh, Y. H., Hur, S., Kim, S. J., Chai, J. W., & Kang, H. S.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2011-07
- Volume
- 197
- Issue
- 1
- Pages
- W134-W140
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1988440962
- Cited by
- 234
- References
- 3
- FWCI
- 5.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.