Two-Time-Point FDG PET/CT: Liver SULmean Repeatability

Open access
Tahari, Abdel K., Paidpally, Vasavi, Chirindel, Alin, Wahl, Richard L., Subramaniam, Rathan M.·2015·American Journal of Roentgenology

Abstract

OBJECTIVE. The purpose of this study was to evaluate the repeatability of liver mean standardized uptake value normalized to lean body mass (SULmean) in the same patients at different time points within the right lobe of the liver at (18)F-FDG PET/CT, in a clinical setting. MATERIALS AND METHODS. Two PET/CT studies performed on two different dates from each of 130 patients who had normal livers according to structural imaging were included in this reader study. The mean (± SD) length of time between the studies was 235 ± 192 days. SULmean was measured with a 30-mm diameter spherical volume of interest (VOI) placed within the right lobe of the liver (above, below, and at the level of the main portal vein) by two expert readers. ANOVA, intraclass correlation coefficient (ICC), and Bland-Altman analysis were performed. RESULTS. The ICC for the first and second set of studies varied between 0.487 and 0.535 for reader 1 and between 0.472 and 0.545 for reader 2. The mean percentage variation for SULmean between the two time scans for the VOIs placed above, below, and at the level of the main portal vein were 3.55% ± 23.19%, 4.65% ± 23.87%, and 4.30% ± 23.03%, respectively, for reader 1 and 4.49% ± 23.23%, 4.33% ± 23.74%, and 4.48% ± 23.01%, respectively, for reader 2. Using 95% CI, the reference range for intrapatient variations between the studies in liver SULmean was -0.5 to 0.60. CONCLUSION. There is only fair repeatability of liver SULmean measured between two time points in the same patient in a clinical setting. Scan-to-scan intrapatient variation in absolute liver SULmean was -0.5 to 0.60.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.14.12719

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The repeatability of the liver SULmean under clinical conditions in the same patient during treatment has been shown to be only fair (intraclass correlation coefficient <0.6).

    “Still, the repeatability of the liver SULmean under clinical conditions in the same patient during treatment has been shown to be only fair (intraclass correlation coefficient <0.6) [195].”

    From Influences on PET Quantification and Interpretation (2022) · cites this paper as [195]

    The Results report same-patient, two-time-point liver SULmean ICCs below 0.6, and the Conclusion calls the correlation fair. The Materials and Methods do not establish that the patients were undergoing treatment between scans; they exclude patients who received chemotherapy or radiation therapy involving the abdomen. Thus, the 'during treatment' qualification is not supported. (LLM, conf=0.88)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 26 references couldn’t be matched to a known paper.

Research works printed but not linked: 1

  1. [18]de Langen AJ Vincent A Velasquez LM Repeatability of 18F-FDG uptake measurements in tumors: a metaanalysis J Nucl Med 2012 53 701 708 22496583

Cited by

Sorted by citations

Authors
Tahari, A. K., Paidpally, V., Chirindel, A., Wahl, R. L., & Subramaniam, R. M.
Affiliations
Johns Hopkins University (US)
Venue
American Journal of Roentgenology
Published
2015-02
Volume
204
Issue
2
Pages
402-407
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2035745380
Cited by
10
References
26
Citations by year
2022: 2 · 2021: 1 · 2019: 1 · 2018: 3 · 2017: 2 · 2016: 1
FWCI
1.62
Type
journal article
Language
en
Open access
Locations
  • American Journal of Roentgenology (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Cancer Institute (P30CA006973)
  • National Institute of Biomedical Imaging and Bioengineering (T32EB006351)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Epidemiology › Liver Disease Diagnosis and Treatment
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
Keywords
18F-FDG PET/CT, standardized uptake value, liver imaging, right hepatic lobe, portal vein
MeSH terms
Adult, Aged, Aged, 80 and over, Female, Humans, Liver, Male, Middle Aged, Retrospective Studies, Time Factors, Tomography, X-Ray Computed, Radiopharmaceuticals, Fluorodeoxyglucose F18, Positron-Emission Tomography, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review